4-10. Remote 14 Receptacle Information
| Socket* | Socket Information |
24 VOLTS AC | A | 24 volts ac. Protected by circuit breaker CB2. |
| B | Contact closure to A completes 24 volts ac contactor control circuit. |
115 VOLTS AC | I | 115 volts ac. Protected by circuit breaker CB1. |
| J | Contact closure to I completes 115 volts ac contactor control circuit. |
| C | Output to remote control; +10 volts dc in MIG mode. |
REMOTE | D | Remote control circuit common. |
OUTPUT | E | 0 to +10 volts dc input command signal from remote control. |
CONTROL | ||
| M | Remote mode select. |
A/V | F | Current feedback; +1 volt dc per 100 amperes. |
AMPERAGE |
|
|
VOLTAGE | H | Voltage feedback; +1 volt dc per 10 arc volts. |
| ||
| G | Circuit common for 24 and 115 volts ac circuits. |
GND | K | Chassis common. |
| ||
*The remaining sockets are not used. |
|
|
|
| |
|
| ! Turn off power before con- |
|
| necting to Remote 14 recep- |
|
| tacle. |
|
| 1 Remote 14 Receptacle RC14 |
|
| Connect remote control to RC14. |
B A K J I
1
C L N H
D M G
E F
OROR
Ref. 800