Miller Electric NT 450, NT 500 Remote 14 Receptacle Information, Connecting Remote Control, Tacle

Page 23

4-10. Remote 14 Receptacle Information

 

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

 

B

Contact closure to A completes 24 volts ac contactor control circuit.

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB1.

 

J

Contact closure to I completes 115 volts ac contactor control circuit.

 

C

Output to remote control; +10 volts dc in MIG mode.

REMOTE

D

Remote control circuit common.

OUTPUT

E

0 to +10 volts dc input command signal from remote control.

CONTROL

 

M

Remote mode select.

A/V

F

Current feedback; +1 volt dc per 100 amperes.

AMPERAGE

 

 

VOLTAGE

H

Voltage feedback; +1 volt dc per 10 arc volts.

 

 

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

 

*The remaining sockets are not used.

 

 

4-11. Connecting Remote Control

 

 

 

! Turn off power before con-

 

 

necting to Remote 14 recep-

 

 

tacle.

 

 

1 Remote 14 Receptacle RC14

 

 

Connect remote control to RC14.

B A K J I

1

C L N H

D M G

E F

OROR

Ref. 800 166-D / Ref. S-0004-A / S-0750

OM-2252 Page 19

Image 23
Contents File Multiprocess Welding OM-2252218 084RProcesses DescriptionFrom Miller to You Table of Contents Page HOT Parts can cause severe burns Symbol UsageArc Welding Hazards Electric Shock can killFlying Metal or Dirt can injure eyes Fumes and Gases can be hazardousARC Rays can burn eyes and skin Welding can cause fire or explosionMoving Parts can cause injury Welding Wire can cause injuryFire or Explosion hazard Falling Unit can cause injuryAbout Implanted Medical Devices Principal Safety StandardsCalifornia Proposition 65 Warnings EMF InformationUNE Décharge Électrique peut entraîner la mort Symboles utilisésLE Soudage peut provoquer un in cendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures gravesLES Fumées ET LES GAZ peuvent être dangereux LA Chute DE L’APPAREIL peut blesser LE Bruit peut endommager l’ouïeLES Bouteilles peuvent exploser si elles sont endommagées Risque D’INCENDIE OU D’EXPLO- SionLE Soudage À L’ARC risque de provoquer des interférences Proposition californienne 65 AvertissementsLES Fils DE Soudage peuvent provoquer des blessures En ce qui concerne les implants médicaux Principales normes de sécuritéInformation EMF OM-2252 − Definitions General Precautionary Label? a Nameplate Safety SymbolsInput Connection Label Electric Shock And Airflow LabelDuty Cycle And Overheating − InstallationSpecifications 100 200 300 400 500 600 CC ModeCV Mode Volt-Ampere Curves460 mm OM-2252 Selecting a LocationMovement 460 mm376 lb 171 kg Holes EFront Dimensions And WeightsDimensions WeightVAC Receptacle And Circuit Breakers Do not move or operate unit where it could tipTurn Off power before connecting to receptacle TippingWeld Output Terminals And Selecting Cable Sizes Connecting Weld Output CablesSocket Connecting Remote ControlTurn off power before con Remote 14 Receptacle InformationPlacing Jumper Links Electrical Service Guide= GND/PE Earth Ground Connecting Input PowerWelding Power Source Input Power Connections Disconnect Device Input Power Connec- tionsControls − OperationMeter Functions For CC/CV Models Lift-Arc TIG Procedure For CC/CV ModelsDisconnect input power be- fore opening rear access door − Maintenance & TroubleshootingRoutine Maintenance Disconnect power before maintainingHelp 7 Display Voltmeter/Ammeter Help DisplaysHelp 3 Display Trouble Remedy TroubleshootingWork like a Pro Circuit Diagram For Dimension NT − Electrical Diagram218 081-F Main Assembly − Parts ListTHERMISTOR, NTC 10K OHM @ 25 DEG C 34IN Lead 264 Panel, Front With ComponentsPanel, Front With Components -1Item IGBT/Capacitor Assembly 221 IGBT/Capacitor Assembly -1itemPanel, Rear With Components Page Work like a Pro Support ServiceYour distributor also gives Your distributor and/or equipment manufacturer’s To locate a Distributor or Service Agency visitMiller Electric Mfg. Co For assistance in filing or settling claims, contact