Miller Electric M-15 manual Symbol Usage, Arc Welding Hazards, Electric Shock can kill

Page 5

SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING

som _nd_5/97

1-1. Symbol Usage

Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.

YMarks a special safety message.

.Means “Note”; not safety related.

This group of symbols means Warning! Watch Out! possible ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the hazards.

1-2. Arc Welding Hazards

YThe symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-4. Read and follow all Safety Standards.

YOnly qualified persons should install, operate, maintain, and repair this unit.

YDuring operation, keep everybody, especially children, away.

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input power circuit and machine internal circuits are also

live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard.

DDo not touch live electrical parts.

DWear dry, hole-free insulating gloves and body protection.

DInsulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground.

DDo not use AC output in damp areas, if movement is confined, or if there is a danger of falling.

DUse AC output ONLY if required for the welding process.

DIf AC output is required, use remote output control if present on unit.

DDisconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards).

DProperly install and ground this equipment according to its Owner’s Manual and national, state, and local codes.

DAlways verify the supply ground – check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet.

DWhen making input connections, attach proper grounding conduc- tor first – double-check connections.

DFrequently inspect input power cord for damage or bare wiring – replace cord immediately if damaged – bare wiring can kill.

DTurn off all equipment when not in use.

DDo not use worn, damaged, undersized, or poorly spliced cables.

DDo not drape cables over your body.

DIf earth grounding of the workpiece is required, ground it directly with a separate cable – do not use work clamp or work cable.

DDo not touch electrode if you are in contact with the work, ground, or another electrode from a different machine.

DUse only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual.

DWear a safety harness if working above floor level.

DKeep all panels and covers securely in place.

DClamp work cable with good metal-to-metal contact to workpiece or worktable as near the weld as practical.

DInsulate work clamp when not connected to workpiece to prevent contact with any metal object.

DDo not connect more than one electrode or work cable to any single weld output terminal.

SIGNIFICANT DC VOLTAGE exists after removal of input power on inverters.

DTurn Off inverter, disconnect input power, and discharge input capacitors according to instructions in Maintenance Section before touching any parts.

FUMES AND GASES can be hazardous.

Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.

DKeep your head out of the fumes. Do not breathe the fumes.

DIf inside, ventilate the area and/or use exhaust at the arc to remove welding fumes and gases.

DIf ventilation is poor, use an approved air-supplied respirator.

DRead the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers.

DWork in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Always have a trained watch- person nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breath- ing air is safe.

DDo not weld in locations near degreasing, cleaning, or spraying op- erations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.

DDo not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and if necessary, while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.

OM-1314 Page 1

Image 5
Contents Description OM-1314Processes From Miller to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards About Pacemakers EMF InformationConsignes DE Securite Lire Avant Utilisation Signification des symbolesUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un incendie ou une explosionDES Particules Volantes peuvent blesser les yeux LA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sé curitéInformation sur les champs é lectromagné tiques Volt-Ampere Curves InstallationSpecifications Overheating Duty Cycle And OverheatingInstalling Gas Supply Installing Work ClampFollow wire manufacturer’s recommendation Do not move or operate unit Where it could tip Electrical Service GuideSelecting a Location And Connecting Input Power Standard Wire Spool Standard Wire Reel Installing Wire Spool And Adjusting Hub TensionInstalling Drive Roll And Threading Welding Wire Weld Parameters OperationControls 14 ga 16 ga 18 ga 20 ga 22 gaMaintenance Maintenance & TroubleshootingMonths Fuse F1Unicable Repair Turn Off power before replacing contact tipReplacing Gun Contact Tip To Reassemble Gun Cleaning Or Replacing Gun LinerDisconnect gun from unit Remove handle Remove switch housing. Note If installing new Replacing Switch And/Or Head TubeTurn Off power before cleaning or repairing drive assembly Cleaning Or Repairing Drive AssemblyWelding Trouble Remedy TroubleshootingCircuit Diagram Electrical DiagramTypical MIG Process Connections MIG Welding Gmaw GuidelinesWire Recommendation Wire Speed Typical MIG Process Control SettingsSelect Wire Size Select VoltageHolding And Positioning Welding Gun Conditions That Affect Weld Bead Shape Gun Movement During Welding Poor Weld Bead CharacteristicsGood Weld Bead Characteristics Troubleshooting Porosity Troubleshooting Excessive SpatterTroubleshooting Excessive Penetration Possible Causes Corrective ActionsTroubleshooting Burn-Through Troubleshooting Lack Of PenetrationTroubleshooting Incomplete Fusion Troubleshooting Distortion Troubleshooting Waviness Of BeadFlat & Horizontal1 Fillet Common MIG Shielding GasesApplication OM-1314 Main Assembly Parts ListDia Part Mkgs Description Quantity M-15 Gun M-15 Gun -1 Item 169Drive Assembly, Wire -1 Item Support ServiceMiller Electric Mfg. Co Owner’s Record

M-15 specifications

Miller Electric M-15 is a highly regarded welding machine designed to cater to a variety of welding applications in both industrial and commercial environments. Known for its reliability and efficiency, the M-15 stands out in the Miller Electric lineup due to its impressive performance and user-friendly features.

One of the primary characteristics of the M-15 is its versatility. It supports multiple welding processes, including MIG, TIG, and Stick welding. This multi-process capability allows operators to switch between different techniques without needing to change equipment, making it an ideal choice for fabricators and maintenance professionals who handle various welding tasks.

The M-15 is engineered with advanced inverter technology, which enhances its performance and efficiency. This technology allows for a lightweight design while still delivering powerful output. The machine offers a wide range of amperage, making it suitable for welding thin materials as well as thicker sections. As a result, the M-15 can tackle everything from delicate sheet metal projects to robust structural welds.

Another standout feature is its intuitive control panel, which simplifies operation for both novice and experienced welders. The easy-to-read display provides essential information regarding settings and performance, allowing users to make adjustments on the fly. This user-friendly interface minimizes the learning curve and maximizes productivity in the workshop.

In terms of safety, the Miller Electric M-15 incorporates several features designed to protect users during operation. Its built-in thermal overload protection automatically shuts down the machine in case of overheating, thus preventing damage to the equipment and ensuring the safety of the operator.

Durability is also a hallmark of the M-15. Constructed with high-quality materials, this welding machine is built to withstand the rigors of daily use in demanding environments. The housing is designed to protect internal components from dust, debris, and accidental impacts, ensuring consistent performance over time.

Overall, the Miller Electric M-15 combines advanced technology, versatility, and reliability into a compact and powerful welding machine. Its user-friendly design, safety features, and robust construction make it a top choice for professionals looking to invest in a reliable welding solution. Whether for heavy industrial applications or lighter fabrication work, the M-15 is equipped to meet a wide range of welding challenges with confidence.