Miller Electric OM-842 Model Name Serial/Style Number Purchase Date, Miller Electric Mfg. Co

Page 64

Owner’s Record

Please complete and retain with your personal records.

Model Name

Serial/Style Number

Purchase Date

(Date which equipment was delivered to original customer.)

 

 

Distributor

 

 

 

Address

 

 

 

City

 

 

 

State

Zip

 

 

For Service

Call 1-800-4-A-Miller or see our website at www.MillerWelds.com to locate a DISTRIBUTOR or SERVICE AGENCY near you.

Always provide Model Name and Serial/Style Number.

Contact your Distributor for:

Welding Supplies and Consumables

 

Options and Accessories

 

Personal Safety Equipment

 

Service and Repair

 

Replacement Parts

 

Training (Schools, Videos, Books)

 

Technical Manuals (Servicing Information

 

and Parts)

 

Circuit Diagrams

 

Welding Process Handbooks

 

 

Contact the Delivering Carrier for:

File a claim for loss or damage during

 

shipment.

For assistance in filing or settling claims,

 

contact your distributor and/or equipment

 

manufacturer’s Transportation Department.

 

 

 

PRINTED IN USA

2000 Miller Electric Mfg. Co. 6/00

Miller Electric Mfg. Co.

An Illinois Tool Works Company

1635 West Spencer Street

Appleton, WI 54914 USA

International Headquarters–USA

USA Phone: 920-735-4505 Auto-Attended

USA & Canada FAX: 920-735-4134

International FAX: 920-735-4125

European Headquarters –

United Kingdom

Phone: 44 (0) 1204-593493

FAX: 44 (0) 1204-598066

www.MillerWelds.com

Image 64
Contents Processes OM-842162074BDescription From Miller to You Table of Contents Page Symbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersSignification des symboles Consignes DE Securite Lire Avant UtilisationUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un incendie ou une explosionLE Bruit peut affecter l’ouïe Risque D’INCENDIE OU LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresInformation sur les champs é lectromagné tiques Principales normes de sé curitéConsignes relatives aux stimulateurs cardiaques Connecting Remote Pendant Or Equivalent User-Wired Control InstallationRemote 4 Socket Information Pulse signal, and for a wire feeder User Relay ContactsSetting DIP Switch SW1 Rocker Switch Settings = On = OffSafety Equipment OperationControls Work ClampAmmeter And Voltmeter Mode Selector SwitchDigital Display Program/Run/Reset Keyed Switch Parameter Select Push ButtonRight/Increase Push Button Left/Decrease Push ButtonRemote Pendant Purge Push ButtonShielding Gas Introduction to Programming GeneralWeld Sequence Balance ControlAutomatic Mode Sequence Semi-Automatic Mode SequenceModes Of Operation Start Level Not Shown Time & level programmedInitial Current C Final Slope Current B Current D Preflow Weld/PeakWeld/Peak Initial Current C Final SlopeSlope Current B Semi-Automatic 4 Mode Sequence Weld/Peak Initial C Current D Final SlopeSlope Current BSmaw Mode Weld/Peak Initial Current B Final Slope SlopePreflow Postflow Initial Slope Weld/Peak Current Final Slope Final CurrentProgramming Automatic Mode Procedure Up To Pulse Mode SelectionProcedure With Pulse Mode On, Pulses Defined In Time Values Procedure With Pulse Mode On, Pulses Defined As a Frequency Procedure Following Pulse Mode DefinitionN a L S T F L O WSemi-Automatic Mode A R TO P E R E M O T E T O A R T# 0 X I N I T I a L P S = X X X Procedure With Pulse Mode On, Pulses Defined As a Frequency O P B U T T O N D E T E C T X X X X X X XManual Gtaw Mode R R E N T C O N T R O L X X X XEditing a Program Smaw Mode# 0 X a R C C O N T R O L R C E N T a G E = 0 0 0 % Dry Run Feature Stop Watch FeatureLinking Programs N K P O S I T I O N X X X X X X XCombining Programs M B I N E M O D EO G R a M L I N K M O D E M B I N E P O S I T I O N X X I S X X X X X XGas Tungsten Arc Welding Gtaw In The Automatic Mode Shared Initial ProcedureSequence of Operation Gas Tungsten Arc Welding Gtaw In The Semi-Automatic ModesOperation Procedures For Semi-Automatic 1 Mode Operation Procedures For Semi-Automatic 2 ModeOperation Procedures For Semi-Automatic 3 Mode Operation Procedures For Semi-Automatic 4 ModeGas Tungsten Arc Welding Gtaw In The Manual Mode Operation Procedures For Semi-Automatic 5 ModeShielded Metal Arc Welding Smaw Executing Linked ProgramsExecuting Combined Programs Shutting DownOverheating Protection DiagnosticsIntroduction Programming Push Button Tests Diagnostics ProgramRAM Test Program/Run/Reset Keyed Switch Tests Repeating Test DisplaysOutput Selector Switch Test Mode Selector Switch TestW O R K I N G O P E R L Y E a S E T U R N K N O B T OPurge Push Button Test R G E B U T T O N S T+10 Volt DC Reference Test Background Relay Test Arc Starter Relay TestGas Solenoid Relay Test User RelaysRemote Pendant Test M O T E P E N D a N T S TR E M O T E S H D E C R E a S E B U T T O N R E M O T ECurrent Detect Test Input Contactor TestP U T C O N T a C T O R D E T E C T E D P U T C O N T a C T O R I S T D E T E C T E DElectrical Diagrams Circuit Diagram For Remote PendantWiring Diagram For MPC Module Circuit Diagram For Welding Power Source And MPC SC-182 947-B Parts List Main AssemblyDia Part Mkgs Description Quantity NAMEPLATE, order by model and serial number 158078 010 110132 Page Page Page Page Service SupportDistributor Address City State Zip Model Name Serial/Style Number Purchase DateMiller Electric Mfg. Co