Miller Electric OM-842 manual EMF Information, About Pacemakers

Page 8

1-5. EMF Information

Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields

Welding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power- frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

To reduce magnetic fields in the workplace, use the following procedures:

1.Keep cables close together by twisting or taping them.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep welding power source and cables as far away from opera- tor as practical.

5.Connect work clamp to workpiece as close to the weld as possi- ble.

About Pacemakers:

Pacemaker wearers consult your doctor first. If cleared by your doctor, then following the above procedures is recommended.

OM-842 Page 4

Image 8
Contents Description OM-842162074BProcesses From Miller to You Table of Contents Page Symbol Usage Marks a special safety message Arc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersSignification des symboles Consignes DE Securite Lire Avant UtilisationUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un incendie ou une explosionDES Particules Volantes peuvent blesser les yeux Risque D’INCENDIE OU LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sé curitéInformation sur les champs é lectromagné tiques Remote 4 Socket Information InstallationConnecting Remote Pendant Or Equivalent User-Wired Control Pulse signal, and for a wire feeder User Relay ContactsSetting DIP Switch SW1 Rocker Switch Settings = On = OffSafety Equipment OperationControls Work ClampDigital Display Mode Selector SwitchAmmeter And Voltmeter Program/Run/Reset Keyed Switch Parameter Select Push ButtonRight/Increase Push Button Left/Decrease Push ButtonShielding Gas Purge Push ButtonRemote Pendant Introduction to Programming GeneralWeld Sequence Balance ControlAutomatic Mode Sequence Semi-Automatic Mode SequenceModes Of Operation Start Level Not Shown Time & level programmedWeld/Peak Initial Current C Final SlopeSlope Current B Weld/PeakInitial Current C Final Slope Current B Current D Preflow Semi-Automatic 4 Mode Sequence Weld/Peak Initial C Current D Final SlopeSlope Current BSmaw Mode Weld/Peak Initial Current B Final Slope SlopePreflow Postflow Initial Slope Weld/Peak Current Final Slope Final CurrentProgramming Automatic Mode Procedure Up To Pulse Mode SelectionProcedure With Pulse Mode On, Pulses Defined In Time Values Procedure With Pulse Mode On, Pulses Defined As a Frequency Procedure Following Pulse Mode DefinitionN a L S T F L O WSemi-Automatic Mode A R TO P E R E M O T E T O A R T# 0 X I N I T I a L P S = X X X Procedure With Pulse Mode On, Pulses Defined As a Frequency O P B U T T O N D E T E C T X X X X X X XManual Gtaw Mode R R E N T C O N T R O L X X X X# 0 X a R C C O N T R O L R C E N T a G E = 0 0 0 % Smaw ModeEditing a Program Dry Run Feature Stop Watch FeatureLinking Programs N K P O S I T I O N X X X X X X XCombining Programs M B I N E M O D EO G R a M L I N K M O D E M B I N E P O S I T I O N X X I S X X X X X XGas Tungsten Arc Welding Gtaw In The Automatic Mode Shared Initial ProcedureSequence of Operation Gas Tungsten Arc Welding Gtaw In The Semi-Automatic ModesOperation Procedures For Semi-Automatic 1 Mode Operation Procedures For Semi-Automatic 2 ModeOperation Procedures For Semi-Automatic 3 Mode Operation Procedures For Semi-Automatic 4 ModeGas Tungsten Arc Welding Gtaw In The Manual Mode Operation Procedures For Semi-Automatic 5 ModeShielded Metal Arc Welding Smaw Executing Linked ProgramsExecuting Combined Programs Shutting DownIntroduction DiagnosticsOverheating Protection RAM Test Diagnostics ProgramProgramming Push Button Tests Program/Run/Reset Keyed Switch Tests Repeating Test DisplaysOutput Selector Switch Test Mode Selector Switch TestW O R K I N G O P E R L Y E a S E T U R N K N O B T OPurge Push Button Test R G E B U T T O N S T+10 Volt DC Reference Test Background Relay Test Arc Starter Relay TestGas Solenoid Relay Test User RelaysRemote Pendant Test M O T E P E N D a N T S TR E M O T E S H D E C R E a S E B U T T O N R E M O T ECurrent Detect Test Input Contactor TestP U T C O N T a C T O R D E T E C T E D P U T C O N T a C T O R I S T D E T E C T E DElectrical Diagrams Circuit Diagram For Remote PendantWiring Diagram For MPC Module Circuit Diagram For Welding Power Source And MPC SC-182 947-B Parts List Main AssemblyDia Part Mkgs Description Quantity NAMEPLATE, order by model and serial number 158078 010 110132 Page Page Page Page Service SupportMiller Electric Mfg. Co Model Name Serial/Style Number Purchase DateDistributor Address City State Zip