5-3. Voltmeter/Ammeter Help Displays

VA

1

HE.L P–0

 

V

 

A

2

HE.L

 

P–1

 

 

 

 

 

 

 

V

 

A

3

HE.L P–2

 

V

 

A

4

 

 

 

HE.L

 

P–3

 

 

 

 

 

 

 

V

 

A

5

HE.L P–4

VA

6

HE.L P–5

 

V

 

A

7

HE.L

 

P–6

 

 

 

 

 

 

 

V

 

A

8

HE.L P–7

 

V

 

A

9

 

 

 

HE.L

 

P–8

 

 

 

 

 

 

 

V

 

A

10

HE.L P–9

.All directions are in reference to the front of the unit. All circuitry referred to is lo- cated inside the unit.

1 Help 0 Display

Indicates a shorted thermistor RT2 on the left side of the unit. If this display is shown, con- tact a Factory Authorized Service Agent.

2 Help 1 Display

Indicates a malfunction in the primary power circuit. If this display is shown, contact a Fac- tory Authorized Service Agent.

3 Help 2 Display

Indicates a malfunction in the thermal protection circuitry located on the left side of the unit. If this display is shown, contact a Factory Authorized Service Agent.

4 Help 3 Display

Indicates the left side of the unit has over- heated. The unit has shut down to allow the

fan to cool it (see Section 3-2). Operation will continue when the unit has cooled.

5 Help 4 Display

Indicates a malfunction in the thermal protection circuitry located on the right side of the unit. If this display is shown, contact a Factory Authorized Service Agent.

6 Help 5 Display

Indicates the right side of the unit has over- heated. The unit has shut down to allow the fan to cool it (see Section 3-2). Operation will continue when the unit has cooled.

7 Help 6 Display

Indicates that the input voltage is too low and the unit has automatically shut down. Opera- tion will continue when the voltage is within the acceptable lower range limit (15% below the applicable input voltage). If this display is

shown, have an electrician check the input voltage.

8 Help 7 Display

Indicates that the input voltage is too high and the unit has automatically shut down. Operation will continue when the voltage is within the acceptable upper range limit (15% above the applicable input voltage). If this display is shown, have an electrician check the input voltage. Help 7 can also indicate a bus voltage imbalance.

9 Help 8 Display

Indicates a malfunction in the secondary power circuit of the unit. If this display is shown, contact a Factory Authorized Ser- vice Agent.

10 Help 9 Display

Indicates a shorted thermistor RT1 on the right side of the unit. If this display is shown, contact a Factory Authorized Service Agent.

OM-193 084 Page 23

Image 27
Contents OM-193 084E ProcessesDescription From Miller to You Table of Contents Standards DirectivesElectric Shock can kill Symbol UsageMarks a special safety message Arc Welding HazardsBuildup of GAS can injure or kill ARC Rays can burn eyes and skinWelding can cause fire or explo- sion Flying Metal can injure eyesPrincipal Safety Standards About Pacemakers EMF InformationLES Fumé ES ET LES GAZ peuvent ê tre dangereux Signification des symbolesConsignes DE Securite Lire Avant Utilisation UN Choc É Lectrique peut tuerLE Soudage peut provoquer un incendie ou une explosion DES Particules Volantes peuvent blesser les yeuxLE Bruit peut affecter l’ouïe DES Organes Mobiles peuvent provoquer des blessures Risque D’INCENDIE OULA Chute DE L’APPAREIL peut blesser ’EMPLOI Excessif peutPrincipales normes de sé curité Information sur les champs é lectromagné tiquesConsignes relatives aux stimulateurs cardiaques Manufacturer’s Warning Label Definitions DefinitionsFalling equipment can cause injury and damage to unit 60 sManufacturer’s Rating Labels Symbols And Definitions I1maxI1eff Installation SpecificationsDuty Cycle And Overheating CC Mode CV ModeVolt-Ampere Curves Movement Dimensions And WeightDo not move or operate unit where it could tip Selecting a LocationTerminals Weld Output Terminals And Selecting Cable SizesRemote 14 Receptacle Information ARC Welding can cause Electromagnetic InterferenceConnecting Input Power Electrical Service GuideFront Panel Controls OperationMeter Functions PPPMode Output Control Mode Switch SettingsLift-Arc Trigger Hold TIG Procedure requiresMaintenance & Troubleshooting Do not remove case when blowing out inside of unitBlowing Out Inside Of Unit Voltmeter/Ammeter Help Displays HE.L P-9Circuit Breakers CB1 And CB2 TroubleshootingCircuit Diagram For Welding Power Source Electrical DiagramMain Assembly Parts ListDia Part 207 OM-193 084 OM-193 084 Support ServiceMiller Electric Mfg. Co Owner’s Record