5-4. Circuit Breakers CB1 And CB2
1 Circuit Breaker CB1
2 Circuit Breaker CB2
CB1 protects 110 volt ac portion of Remote 14 receptacle (see Section
CB2 protects 24 volt ac portion of
CB1 CB2 Remote 14 receptacle from overload.
Press button to reset breaker.
1 2
Ref.
5-5. Troubleshooting
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
| Trouble |
| Remedy | ||
|
|
|
|
| |
No weld output; unit completely inop- | Place line disconnect switch in On position (see Section | ||||
erative. |
|
| |||
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section | |||||
|
|
| |||
|
|
|
|
| |
|
|
| Check for proper input power connections (see Section | ||
|
|
|
|
| |
No weld output; meter display On. | If using remote control, be sure Mode Selector switch is in a position that provides output control at | ||||
|
|
| Remote 14 receptacle. | ||
|
|
|
|
| |
|
|
| Check, repair, or replace remote control. | ||
|
|
|
|
| |
|
|
| Unit overheated. Allow unit to cool with fan On (see Section | ||
|
|
|
|
| |
Erratic or improper weld output. | Use proper size and type of weld cable (see Section | ||||
|
|
|
|
| |
|
|
| Clean and tighten all weld connections. | ||
|
|
|
|
| |
No 110 volts ac output at duplex recep- | Reset circuit breaker CB1 (see Section | ||||
tacle, Remote 14 receptacle. |
|
| |||
|
|
|
|
| |
No 24 volts ac output at Remote 14 re- | Reset circuit breaker CB2 (see Section | ||||
ceptacle. |
|
| |||
|
|
|
|
|