. A complete Parts List is available at www.MillerWelds.com
SECTION 10 − TROUBLESHOOTING
10-1. Welding Troubleshooting
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Trouble |
|
|
| Remedy | ||||||
|
|
| |||||||||
Low or no weld output; generator pow- |
| Check control settings. | |||||||||
er output okay at ac receptacles. |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check weld connections. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check fuse F1, and replace if open (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2 and | ||
|
|
|
|
|
|
|
|
| SR3. | ||
|
| ||||||||||
No weld output or generator power out- | Be sure all equipment is disconnected from receptacles when starting unit. | ||||||||||
put at ac receptacles. |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check fuses F1 and F2, and replace if open (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check plug PLG6 connection. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2, SR3. | ||
|
|
| |||||||||
Low weld output. |
| Check fuse F1, and replace if open (see Section | |||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check control settings. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check engine speed, and adjust if necessary (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Service air cleaner according to engine manual. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2, SR3. | ||
|
|
| |||||||||
High weld output. |
| Check control settings. | |||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check engine speed, and adjust if necessary (see Section | ||
|
|
| |||||||||
Erratic weld output. |
| Check control settings. | |||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Tighten and clean connections to electrode and workpiece. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Use dry, | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Remove excessive coils from weld cables. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Clean and tighten connections both inside and outside welding generator. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check engine speed, and adjust if necessary (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2, SR3. | ||
|
|
|
|
|
|
|
|
|
|
|
|
10-2. Generator Power Troubleshooting
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Trouble |
|
|
| Remedy | ||||||
|
|
| |||||||||
No or low generator power output at ac |
| Reset supplementary protector(s) (see Section | |||||||||
receptacles; weld output okay. |
|
|
|
| |||||||
| Press optional GFCI receptacle Reset button (see Section | ||||||||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check fuse F2, and replace if open (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check plug PLG6 connection. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifier SR3. | ||
|
|
| |||||||||
No generator power or weld output. |
| Be sure all equipment is disconnected from receptacles when starting unit. | |||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check fuses F1 and F2, and replace if open (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check plug PLG6 connection. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2 and | ||
|
|
|
|
|
|
|
|
| SR3. | ||
|
|
|
|
|
|
|
|
|
|
|
|