Simer Pumps 5023SS, 5020B Installation, Risk of electric shock. Pump is designed for 115V., 60 HZ

Page 3

Installation

3

Discharge

About 8"

About 6"

Check

Valve (Purchase Separately)

INSTALLATION

1.This unit can be installed in sump pit with min- imum diameter of 12" (30cm) and depth of 12" (30cm). Sump pit may be constructed of tile, concrete, steel or plastic. Check local codes for approved materials.

2.Install pump on solid, level foundation, as near as possible to center of sump pit. Do not hang pump from discharge pipe or power cord.

Pump must be level (column must be vertical) when oper- ating. If motor is tilted, internal start/run switch

may overheat and damage motor.

3.Pump should not be installed on clay, earth or sand surfaces. Clean sump pit of small stones and gravel which could clog the pump. Keep pump inlet screen clear.

4.Thread discharge pipe into pump body careful- ly to avoid stripping or crossing threads. NOTICE: Do not use ordinary pipe joint com- pound on plastic pipe or pump. Pipe joint com- pound can attack plastics and damage pump.

5.To reduce motor noise and vibrations, a short length of rubber hose (1-5/8" (41mm) I.D., e.g. radiator hose) can be connected into discharge line near pump using suitable clamps.

Risk of electric shock. Pump is designed for 115V., 60 HZ

operation and requires an individual branch cir- cuit of 15 amperes capacity. It is supplied with

a 3-wire cord set with grounding-type plug for use in a 3-wire, grounded outlet. Do not cut off the round grounding prong. For safety, outlet must always be electrically grounded to a suit- able electrical ground such as a grounded water pipe or a properly grounded metallic raceway or ground wire system.

6.Locate Float Rod Guide (Key No. 6) about 6" (16cm) below motor. Clamp guide to column with screw provided.

Risk of flooding. Be sure that guide is securely clamped so

that float rod is vertical and can move up and down freely. If float is angled or binds, pump may not start, allowing flooding to occur.

7.Screw float onto threaded end of rod. Threads on rod will cut threads into corrosion resistant float.

8.Insert plain end of float rod up through eye of rod guide.

9.Slide one rod stop on float rod before passing rod through eye of pump switch. Slide 2nd rod stop on rod after passing through eye of switch. Position 2nd rod stop flush with top of rod.

10.Position lower rod stop to within 8"(20cm) of switch lever arm. With lower rod stop in this position, pump will automatically cycle at approximately 2-1/2" (6cm) off and 10-12"

(25-30cm) on. For faster cycling, move lower rod stop closer to switch lever arm.

11.If pump discharge line is exposed to outside subfreezing atmosphere, then portion of line exposed must be installed so any water remain- ing in pipe will drain to outfall by gravity. Failure to do this can cause water trapped in discharge to freeze which could result in dam- age to pump.

12.Install an in-line check valve to prevent flow backwards through pump after pump shuts off. NOTICE: If using a check valve without an air bleed hole, drill a 1/8" (3.2mm) hole in dis- charge pipe just above pump body but below the check valve to prevent air locks.

13.After all piping and controls have been installed, unit is ready for operation.

14.Run pump through one cycle to check float switch operation.

The pump motor is equipped with automatic resetting

thermal protector and may restart unexpected- ly. Protector tripping is an indication of motor overloading as a result of operating pump at low heads (low discharge restriction), exces- sively high or low voltage, inadequate wiring, incorrect motor connections, or a defective motor.

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 3
Contents Pages Mod B, 5023SSCall Llame alDescription SafetySpecifications General SafetyInstallation InstallationRisk of electric shock. Pump is designed for 115V., 60 HZ Troubleshooting OperationOperation Key Part Repair PartsSwitch FP0018-7D ModelRetain Original Receipt for Your Records WarrantySécurité Caractéristiques TechniquesRendement Risques de débordement Risques d’électrocutionFiche de terre pour usage sur une prise de courant La terreDébrancher la pompe avant de travailler sur la pompe Diagnostic des pannesFonctionnement FonctionnementInterrupteur FP0018-7D Pièces de rechangeModèle Réf Désignation des piècesPompes D’EAUX D’ÉGOUT GarantieRendimiento SeguridadDescripción EspecificacionesInstalación InstalaciónPeligro de inundación Solución de problemas FuncionamientoFuncionamiento Interruptor FP0018-7D RefaccionesModelo DescripciónBombas Cloacales Garantia

5023SS, 5020B specifications

Simer Pumps is renowned for its commitment to innovative pump technology, and the Simer Pumps 5020B and 5023SS models exemplify this dedication. These pumps are designed to meet a variety of water movement needs, making them ideal for residential, agricultural, and light industrial applications.

The Simer 5020B is a durable thermoplastic pump well-regarded for its versatility. It features a robust motor that operates effectively with a flow rate of up to 1200 gallons per hour. This pump is engineered for continuous operation, making it perfect for draining flooded areas, removing water from basements, or even managing irrigation systems. The 5020B is also equipped with an automatic float switch that activates the pump when water levels rise, ensuring effective water management without the need for manual intervention.

On the other hand, the Simer 5023SS offers superior performance with a stainless-steel construction, adding to its durability and resistance to corrosion. It comes with a powerful motor capable of moving up to 3000 gallons of water per hour, making it suitable for more demanding applications, such as large-scale irrigation or dewatering construction sites. The 5023SS is equipped with a thermal overload protection system, which prevents overheating and prolongs the lifespan of the pump.

Both models are designed with user-friendliness in mind. They provide easy installation options and require minimal maintenance, making them ideal choices for both homeowners and professionals. The ergonomic design ensures that these pumps can be easily transported and placed wherever needed.

In terms of energy efficiency, both the 5020B and 5023SS have been engineered to minimize power consumption while maximizing performance. This makes them not only cost-effective choices but also environmentally friendly.

Overall, the Simer Pumps 5020B and 5023SS stand out for their reliable performance, innovative technology, and ease of use. These pumps are suitable for a variety of applications and are designed to deliver dependable water management solutions for many years. Whether you are looking for a pump for routine home use or for heavier industrial tasks, Simer Pumps delivers robust options that meet diverse needs effectively.