1-3. Engine Hazards

BATTERY EXPLOSION can BLIND.

DAlways wear a face shield, rubber gloves, and

protective clothing when working on a battery.

D Stop engine before disconnecting or connect- ing battery cables or servicing battery.

DDo not allow tools to cause sparks when working on a battery.

DDo not use welder to charge batteries or jump start vehicles.

DObserve correct polarity (+ and −) on batteries.

DDisconnect negative (−) cable first and connect it last.

FUEL can cause fire or explosion.

D Stop engine and let it cool off before checking or adding fuel.

DDo not add fuel while smoking or if unit is near any sparks or open flames.

DDo not overfill tank — allow room for fuel to expand.

DDo not spill fuel. If fuel is spilled, clean up before starting engine.

DDispose of rags in a fireproof container.

DAlways keep nozzle in contact with tank when fueling.

MOVING PARTS can cause injury.

D Keep away from fans, belts, and rotors.

D Keep all doors, panels, covers, and guards closed and securely in place.

DStop engine before installing or connecting unit.

DHave only qualified people remove doors, panels, covers, or guards for maintenance and troubleshooting as necessary.

DTo prevent accidental starting during servicing, disconnect negative (−) battery cable from battery.

DKeep hands, hair, loose clothing, and tools away from moving parts.

DReinstall doors, panels, covers, or guards when servicing is finished and before starting engine.

DBefore working on generator, remove spark plugs or injectors to keep engine from kicking back or starting.

DBlock flywheel so that it will not turn while working on generator components.

HOT PARTS can cause severe burns.

DDo not touch hot parts bare handed.

D Allow cooling period before working on equip- ment.

DTo handle hot parts, use proper tools and/or wear heavy, insulated welding gloves and clothing to prevent burns.

STEAM AND HOT COOLANT can burn.

DIf possible, check coolant level when engine is cold to avoid scalding.

D Always check coolant level at overflow tank, if present on unit, instead of radiator (unless told otherwise in maintenance section or engine manual).

DIf the engine is warm, checking is needed, and there is no over- flow tank, follow the next two statements.

DWear safety glasses and gloves and put a rag over radiator cap.

DTurn cap slightly and let pressure escape slowly before completely removing cap.

Using a generator indoors CAN KILL YOU IN MINUTES.

D Generator exhaust contains carbon monoxide.

This is a poison you cannot see or smell.

DNEVER use inside a home or garage, EVEN IF doors and windows are open.

DOnly use OUTSIDE and far away from windows, doors, and vents.

BATTERY ACID can BURN SKIN and EYES.

DDo not tip battery.

DReplace damaged battery.

DFlush eyes and skin immediately with water.

ENGINE HEAT can cause fire.

D Do not locate unit on, over, or near combustible surfaces or flammables.

DKeep exhaust and exhaust pipes way from flammables.

EXHAUST SPARKS can cause fire.

D Do not let engine exhaust sparks cause fire.

DUse approved engine exhaust spark arrestor in required areas — see applicable codes.

1-4. Compressed Air Hazards

BREATHING COMPRESSED AIR can cause serious injury or death.

DDo not use compressed air for breathing.

DUse only for cutting, gouging, and tools.

COMPRESSED AIR can cause injury.

DWear approved safety goggles.

DDo not direct air stream toward self or others.

TRAPPED AIR PRESSURE AND WHIPPING HOSES can cause injury.

DRelease air pressure from tools and system be- fore servicing, adding or changing attach- ments, or opening compressor oil drain or oil fill cap.

OM-4433 Page 3

Image 7
Contents File Engine Drive OM-4433218 314PProcesses DescriptionFrom Miller to You Table of Contents Warranty HOT Parts can cause severe burns Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion Fumes and Gases can be hazardousBuildup of GAS can injure or kill ARC Rays can burn eyes and skinCompressed Air Hazards Engine HazardsFalling Unit can cause injury Welding Wire can cause injuryHOT Parts can cause burns and injury Fire or Explosion hazardRadiation can cause interference Principal Safety StandardsCalifornia Proposition 65 Warnings EMF InformationIndique des instructions spécifiques Signification des symboles− Consignes DE Sécurité − Lire Avant Utilisation UN Choc Électrique peut tuerLE Bruit peut affecter l’ouïe DES Pièces Chaudes peuvent provoquer des brûlures gravesLES Fumées ET LES GAZ peuvent être dangereux LE Soudage peut provoquer un in cendie ou une explosionDES Organes Mobiles peuvent pro voquer des blessures ’EXPLOSION DE LA Batterie peu’AIR Comprimé peut provoquer des blessures LA Chaleur DU Moteur peut pro- voquer un incendieRisque D’INCENDIE OU D’EXPLO- Sion ’EMPLOI Excessif peut LE Surchauffement peut endom- mager le moteur électriqueDES Organes Mobiles peuvent provoquer des blessures LES Fils DE Soudage peuvent provoquer des blessuresEn ce qui concerne les implants médicaux Proposition californienne 65 AvertissementsPrincipales normes de sécurité Information EMF− 50 h Std − DefinitionsStd Manufacturer’s Rating Label Some symbols are found only on CE products Symbols And DefinitionsWeld, Power, And Engine Specifications − SpecificationsDimensions, Weights, And Operating Angles Volt-Ampere Curves Stick ModeMIG Mode TIG ModeThis unit is rated for welding at 250 amperes continuously Curve shows typical fuel use under weld or power loadsFuel Consumption Duty Cycle And Overheating150 125 100 AC Generator Power CurveGrounding1 − InstallationInstalling Welding Generator Location/Airflow ClearanceTo Weld Unit In Place Mounting Welding GeneratorSupporting The Unit Mounting SurfacePoint exhaust pipe in desired di Installing Exhaust PipeTools Needed 1/2 Stop engine and let coolClose door after connecting battery Activating The Dry Charge Battery If ApplicableConnecting The Battery Do not overfill battery cellsOil Coolant Recovery TankEngine Prestart Checks FuelStop engine Connecting To Weld Output TerminalsStick and TIG Welding MIG and Fcaw WeldingSelecting Weld Cable Sizes Stop engine Before Connecting to Weld Output terminals150 ft 200 ft 250 ft Socket Information Connecting To Remote 14 Receptacle RC14Welding Symbols Front Panel Controls See Section − Operating Welding GeneratorDescription Of Front Panel Controls See Section Process/Contactor Switch Settings Process/Contactor SwitchLift-Arc t TIG Lift-ArcStart ProcedureLift-Arc Start Method Touch Do not Strike Like a MatchRemote Voltage/Amperage Control − Operating Auxiliary Equipment Generator Power ReceptaclesAt least once a month, run engine at Routine Maintenance − Maintenance & TroubleshootingMaintenance Label To clean air filter Servicing Air CleanerServicing Engine Cooling System Inspecting And Cleaning Optional Spark Arrestor MufflerDo not set engine speed higher Adjusting Engine Speed On Standard ModelsMay affect engine warranty MaximumRpm max 62.6 Hz 1500 rpm 50 Hz Engine Speed AdjustmentWeld/Power Speed Adjustment Engine Speed No LoadTo drain water from fuel system Servicing Fuel And Lubrication SystemsTo change oil and filter To replace primary canister fuel filterOverload Protection Replace Damaged Brushes Checking Generator BrushesHelp 20 Display Voltmeter/Ammeter Help DisplaysHelp 25 Display Welding TroubleshootingEngine Generator PowerCheck for obstructed throttle solenoid Material Thickness Reference Chart Circuit Diagram For Welding Generator − Electrical Diagrams219 228−E Wetstacking − RUN-IN ProcedureWelding Generator Cycle or equipment damage may Run-In Procedure Using Load BankFrom flammables Output and do not exceed dutyRun-In Procedure Using Resistance Grid Selecting Equipment − Generator Power GuidelinesGrounding Generator To Truck Or Trailer Frame Amperes x Volts = Watts Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Use ground device as stated in electrical codesFarm/Home Equipment Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Industrial Motors Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentKVA/HP x HP x 1000 / Volts = Starting Amperage Power Required To Start MotorHow Much Power Can Generator Supply? Single-Phase Induction Motor Starting RequirementsTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible 101 111 110 −3 109 108 −2 107 102 103 9897 104 106 105 − Parts List6665 80Fig.12−44243 TE1 Dia Part Description Quantity Mkgs Batt Panel, Front w/Components -1Item Panel, Front w/ComponentsFUEL/HM Control Panel Generator -1Item GeneratorRectifier Assembly Wiring Harnesses Your distributor also gives ServiceSupport Your distributor and/or equipment manufacturer’s To locate a Distributor or Service Agency visitMiller Electric Mfg. Co For assistance in filing or settling claims, contact

Big Blue 300 specifications

The Miller Electric Big Blue 300 is a powerful and versatile engine-driven welder that has become a popular choice for professionals in various industries. Designed to excel in both welding and generator applications, the Big Blue 300 provides reliable performance, advanced technology, and exceptional durability, making it suitable for demanding work environments.

One of the standout features of the Big Blue 300 is its impressive output capabilities. With a maximum welding output of 300 amps, this machine can handle a wide range of welding applications, from stick to TIG and MIG processes. The dual voltage output allows for versatility in the field, accommodating both 120V and 240V power requirements, ensuring you can power tools and equipment directly from the welder.

The Big Blue 300 is equipped with Miller's innovative Clean Air Technology, which ensures that the engine operates efficiently and produces fewer emissions. This feature not only meets environmental standards but also enhances the longevity of the machine. The cooling system is engineered to maintain optimal operating temperatures, extending the life of the engine and related components.

For ease of use, the Big Blue 300 features an intuitive control panel with easy-to-read gauges and simple adjustment settings, allowing operators to quickly set welding parameters. The built-in Fuel Gauge and Hour Meter provide real-time information about fuel levels and usage, enabling efficient operation and maintenance planning.

Another notable characteristic of the Big Blue 300 is its rugged construction. Built to withstand harsh job site conditions, the machine features a durable frame and heavy-duty components that can endure the rigors of everyday use. The oversized wheels and solid axle design enhance portability, making it easy to transport across various terrains.

Additionally, the Big Blue 300 is designed for quiet operation, making it suitable for locations where noise levels are a concern. Its low decibel rating ensures that it won’t disturb the work environment, contributing to a more comfortable and productive atmosphere.

Overall, the Miller Electric Big Blue 300 is a robust engine-driven welder that combines power, efficiency, and portability. Whether working on construction sites, maintenance tasks, or fabrication projects, this machine delivers exceptional performance and reliability, making it a valuable tool for professionals who demand the best in their equipment.