Miller Electric Big Blue 300 manual Symbol Usage, Arc Welding Hazards, Electric Shock can kill

Page 5

SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING

rom_2007−04

Protect yourself and others from injury — read and follow these precautions.

1-1. Symbol Usage

DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury. The possible hazards are shown in the adjoining symbols or explained in the text.

Indicates a hazardous situation which, if not avoided, could result in death or serious injury. The possible hazards are shown in the adjoining symbols or ex- plained in the text.

NOTICE − Indicates statements not related to personal injury.

.Indicates special instructions.

This group of symbols means Warning! Watch Out! ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult sym- bols and related instructions below for necessary actions to avoid the hazards.

1-2. Arc Welding Hazards

The symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-7. Read and follow all Safety Standards.

Only qualified persons should install, operate, maintain, and repair this unit.

During operation, keep everybody, especially children, away.

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input

power circuit and machine internal circuits are also live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equip- ment is a hazard.

DDo not touch live electrical parts.

DWear dry, hole-free insulating gloves and body protection.

DInsulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground.

DDo not use AC output in damp areas, if movement is confined, or if there is a danger of falling.

DUse AC output ONLY if required for the welding process.

DIf AC output is required, use remote output control if present on unit.

DAdditional safety precautions are required when any of the follow- ing electrically hazardous conditions are present: in damp locations or while wearing wet clothing; on metal structures such as floors, gratings, or scaffolds; when in cramped positions such as sitting, kneeling, or lying; or when there is a high risk of unavoid- able or accidental contact with the workpiece or ground. For these conditions, use the following equipment in order presented: 1) a semiautomatic DC constant voltage (wire) welder, 2) a DC manual (stick) welder, or 3) an AC welder with reduced open-circuit volt- age. In most situations, use of a DC, constant voltage wire welder is recommended. And, do not work alone!

DDisconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards).

DProperly install and ground this equipment according to its Owner’s Manual and national, state, and local codes.

DAlways verify the supply ground — check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet.

DWhen making input connections, attach proper grounding conduc- tor first − double-check connections.

DKeep cords dry, free of oil and grease, and protected from hot metal and sparks.

DFrequently inspect input power cord for damage or bare wiring — replace cord immediately if damaged — bare wiring can kill.

DTurn off all equipment when not in use.

DDo not use worn, damaged, undersized, or poorly spliced cables.

DDo not drape cables over your body.

DIf earth grounding of the workpiece is required, ground it directly with a separate cable.

DDo not touch electrode if you are in contact with the work, ground, or another electrode from a different machine.

DUse only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual.

DDo not touch electrode holders connected to two welding ma- chines at the same time since double open-circuit voltage will be present.

DWear a safety harness if working above floor level.

DKeep all panels and covers securely in place.

DClamp work cable with good metal-to-metal contact to workpiece or worktable as near the weld as practical.

DInsulate work clamp when not connected to workpiece to prevent contact with any metal object.

DDo not connect more than one electrode or work cable to any single weld output terminal.

SIGNIFICANT DC VOLTAGE exists in inverters after stop- ping engine.

DStop engine on inverter and discharge input capacitors according to instructions in Maintenance Section before touching any parts.

HOT PARTS can cause severe burns.

DDo not touch hot parts bare handed.

D Allow cooling period before working on equip- ment.

DTo handle hot parts, use proper tools and/or wear heavy, insu- lated welding gloves and clothing to prevent burns.

FLYING METAL or DIRT can injure eyes.

DWelding, chipping, wire brushing, and grinding cause sparks and flying metal. As welds cool, they can throw off slag.

DWear approved safety glasses with side shields even under your welding helmet.

OM-4433 Page 1

Image 5
Contents Processes OM-4433218 314PDescription File Engine DriveFrom Miller to You Table of Contents Warranty Arc Welding Hazards Symbol UsageElectric Shock can kill HOT Parts can cause severe burnsBuildup of GAS can injure or kill Fumes and Gases can be hazardousARC Rays can burn eyes and skin Welding can cause fire or explosionCompressed Air Hazards Engine HazardsHOT Parts can cause burns and injury Welding Wire can cause injuryFire or Explosion hazard Falling Unit can cause injuryCalifornia Proposition 65 Warnings Principal Safety StandardsEMF Information Radiation can cause interference− Consignes DE Sécurité − Lire Avant Utilisation Signification des symbolesUN Choc Électrique peut tuer Indique des instructions spécifiquesLES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures gravesLE Soudage peut provoquer un in cendie ou une explosion LE Bruit peut affecter l’ouïeDES Organes Mobiles peuvent pro voquer des blessures ’EXPLOSION DE LA Batterie peuRisque D’INCENDIE OU D’EXPLO- Sion LA Chaleur DU Moteur peut pro- voquer un incendie’AIR Comprimé peut provoquer des blessures DES Organes Mobiles peuvent provoquer des blessures LE Surchauffement peut endom- mager le moteur électriqueLES Fils DE Soudage peuvent provoquer des blessures ’EMPLOI Excessif peutPrincipales normes de sécurité Proposition californienne 65 AvertissementsInformation EMF En ce qui concerne les implants médicauxStd − Definitions− 50 h Std Manufacturer’s Rating Label Some symbols are found only on CE products Symbols And DefinitionsDimensions, Weights, And Operating Angles − SpecificationsWeld, Power, And Engine Specifications MIG Mode Stick ModeTIG Mode Volt-Ampere CurvesFuel Consumption Curve shows typical fuel use under weld or power loadsDuty Cycle And Overheating This unit is rated for welding at 250 amperes continuously150 125 100 AC Generator Power CurveInstalling Welding Generator − InstallationLocation/Airflow Clearance Grounding1Supporting The Unit Mounting Welding GeneratorMounting Surface To Weld Unit In PlaceTools Needed 1/2 Installing Exhaust PipeStop engine and let cool Point exhaust pipe in desired diConnecting The Battery Activating The Dry Charge Battery If ApplicableDo not overfill battery cells Close door after connecting batteryEngine Prestart Checks Coolant Recovery TankFuel OilStick and TIG Welding Connecting To Weld Output TerminalsMIG and Fcaw Welding Stop engine150 ft 200 ft 250 ft Stop engine Before Connecting to Weld Output terminalsSelecting Weld Cable Sizes Socket Information Connecting To Remote 14 Receptacle RC14Welding Symbols Front Panel Controls See Section − Operating Welding GeneratorDescription Of Front Panel Controls See Section Process/Contactor Switch Settings Process/Contactor SwitchLift-Arc Start Method Touch Lift-ArcStart ProcedureDo not Strike Like a Match Lift-Arc t TIGRemote Voltage/Amperage Control At least once a month, run engine at Generator Power Receptacles− Operating Auxiliary Equipment Routine Maintenance − Maintenance & TroubleshootingMaintenance Label To clean air filter Servicing Air CleanerServicing Engine Cooling System Inspecting And Cleaning Optional Spark Arrestor MufflerMay affect engine warranty Adjusting Engine Speed On Standard ModelsMaximum Do not set engine speed higherWeld/Power Speed Adjustment Engine Speed AdjustmentEngine Speed No Load Rpm max 62.6 Hz 1500 rpm 50 HzTo change oil and filter Servicing Fuel And Lubrication SystemsTo replace primary canister fuel filter To drain water from fuel systemOverload Protection Replace Damaged Brushes Checking Generator BrushesHelp 25 Display Voltmeter/Ammeter Help DisplaysHelp 20 Display Welding TroubleshootingEngine Generator PowerCheck for obstructed throttle solenoid Material Thickness Reference Chart Circuit Diagram For Welding Generator − Electrical Diagrams219 228−E Welding Generator − RUN-IN ProcedureWetstacking From flammables Run-In Procedure Using Load BankOutput and do not exceed duty Cycle or equipment damage mayRun-In Procedure Using Resistance Grid Grounding Generator To Truck Or Trailer Frame − Generator Power GuidelinesSelecting Equipment How Much Power Does Equipment Require? Grounding When Supplying Building SystemsUse ground device as stated in electrical codes Amperes x Volts = WattsApproximate Power Requirements For Farm/Home Equipment Approximate Power Requirements For Industrial MotorsIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentHow Much Power Can Generator Supply? Power Required To Start MotorSingle-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 / Volts = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible 101 111 110 −3 109 108 −2 107 102 103 9897 104 106 105 − Parts List4243 80Fig.12−46665 TE1 Dia Part Description Quantity Mkgs Batt Panel, Front w/Components -1Item Panel, Front w/ComponentsFUEL/HM Control Panel Generator -1Item GeneratorRectifier Assembly Wiring Harnesses Support ServiceYour distributor also gives Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s

Big Blue 300 specifications

The Miller Electric Big Blue 300 is a powerful and versatile engine-driven welder that has become a popular choice for professionals in various industries. Designed to excel in both welding and generator applications, the Big Blue 300 provides reliable performance, advanced technology, and exceptional durability, making it suitable for demanding work environments.

One of the standout features of the Big Blue 300 is its impressive output capabilities. With a maximum welding output of 300 amps, this machine can handle a wide range of welding applications, from stick to TIG and MIG processes. The dual voltage output allows for versatility in the field, accommodating both 120V and 240V power requirements, ensuring you can power tools and equipment directly from the welder.

The Big Blue 300 is equipped with Miller's innovative Clean Air Technology, which ensures that the engine operates efficiently and produces fewer emissions. This feature not only meets environmental standards but also enhances the longevity of the machine. The cooling system is engineered to maintain optimal operating temperatures, extending the life of the engine and related components.

For ease of use, the Big Blue 300 features an intuitive control panel with easy-to-read gauges and simple adjustment settings, allowing operators to quickly set welding parameters. The built-in Fuel Gauge and Hour Meter provide real-time information about fuel levels and usage, enabling efficient operation and maintenance planning.

Another notable characteristic of the Big Blue 300 is its rugged construction. Built to withstand harsh job site conditions, the machine features a durable frame and heavy-duty components that can endure the rigors of everyday use. The oversized wheels and solid axle design enhance portability, making it easy to transport across various terrains.

Additionally, the Big Blue 300 is designed for quiet operation, making it suitable for locations where noise levels are a concern. Its low decibel rating ensures that it won’t disturb the work environment, contributing to a more comfortable and productive atmosphere.

Overall, the Miller Electric Big Blue 300 is a robust engine-driven welder that combines power, efficiency, and portability. Whether working on construction sites, maintenance tasks, or fabrication projects, this machine delivers exceptional performance and reliability, making it a valuable tool for professionals who demand the best in their equipment.