Miller Electric Big Blue 300 manual California Proposition 65 Warnings, Principal Safety Standards

Page 9

H.F. RADIATION can cause interference.

DHigh-frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment.

DHave only qualified persons familiar with electronic equipment perform this installation.

DThe user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.

DIf notified by the FCC about interference, stop using the equipment at once.

DHave the installation regularly checked and maintained.

DKeep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference.

ARC WELDING can cause interference.

DElectromagnetic energy can interfere with sensitive electronic equipment such as micro- processors, computers, and computer-driven equipment such as robots.

DBe sure all equipment in the welding area is electromagnetically compatible.

DTo reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.

DLocate welding operation 100 meters from any sensitive elec- tronic equipment.

DBe sure this welding machine is installed and grounded according to this manual.

DIf interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.

1-6. California Proposition 65 Warnings

Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)

Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

For Gasoline Engines:

Engine exhaust contains chemicals known to the State of California to cause cancer, birth defects, or other reproduc- tive harm.

For Diesel Engines:

Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.

1-7. Principal Safety Standards

Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers and Piping, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, P.O. Box 9101, Quincy, MA 02269-9101 (phone: 617-770-3000, website: www.nfpa.org and www. sparky.org).

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).

Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 5060 Mississauga,

Ontario, Canada L4W 5NS (phone: 800-463-6727 or in Toronto

416-747-4044, website: www.csa-international.org).

Safe Practice For Occupational And Educational Eye And Face Protec- tion, ANSI Standard Z87.1, from American National Standards Institute,

25 West 43rd Street, New York, NY 10036–8002 (phone:

212-642-4900, website: www.ansi.org).

Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFPA Standard 51B, from National Fire Protection Association, P.O. Box 9101, Quincy, MA 02269-9101 (phone: 617-770-3000, web- site: www.nfpa.org.

OSHA, Occupational Safety and Health Standards for General Indus- try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Super- intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954 (phone: 1-866-512-1800) (there are 10 Regional Offices—phone for Region 5, Chicago, is 312-353-2220, website: www.osha.gov).

1-8. EMF Information

Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields

Welding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power- frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

To reduce magnetic fields in the workplace, use the following procedures:

1.Keep cables close together by twisting or taping them, or using a cable cover.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep welding power source and cables as far away from operator as practical.

5.Connect work clamp to workpiece as close to the weld as possible.

About Implanted Medical Devices:

Implanted Medical Device wearers should consult their doctor and the device manufacturer before performing or going near arc welding, spot welding, gouging, plasma arc cutting, or induction heating operations. If cleared by your doctor, then following the above procedures is recom- mended.

OM-4433 Page 5

Image 9
Contents Processes OM-4433218 314PDescription File Engine DriveFrom Miller to You Table of Contents Warranty Arc Welding Hazards Symbol UsageElectric Shock can kill HOT Parts can cause severe burnsBuildup of GAS can injure or kill Fumes and Gases can be hazardousARC Rays can burn eyes and skin Welding can cause fire or explosionCompressed Air Hazards Engine HazardsHOT Parts can cause burns and injury Welding Wire can cause injuryFire or Explosion hazard Falling Unit can cause injuryCalifornia Proposition 65 Warnings Principal Safety StandardsEMF Information Radiation can cause interference− Consignes DE Sécurité − Lire Avant Utilisation Signification des symbolesUN Choc Électrique peut tuer Indique des instructions spécifiquesLES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures gravesLE Soudage peut provoquer un in cendie ou une explosion LE Bruit peut affecter l’ouïeDES Organes Mobiles peuvent pro voquer des blessures ’EXPLOSION DE LA Batterie peuLA Chaleur DU Moteur peut pro- voquer un incendie ’AIR Comprimé peut provoquer des blessuresRisque D’INCENDIE OU D’EXPLO- Sion DES Organes Mobiles peuvent provoquer des blessures LE Surchauffement peut endom- mager le moteur électriqueLES Fils DE Soudage peuvent provoquer des blessures ’EMPLOI Excessif peutPrincipales normes de sécurité Proposition californienne 65 AvertissementsInformation EMF En ce qui concerne les implants médicaux− Definitions − 50 h StdStd Manufacturer’s Rating Label Some symbols are found only on CE products Symbols And Definitions− Specifications Weld, Power, And Engine SpecificationsDimensions, Weights, And Operating Angles MIG Mode Stick ModeTIG Mode Volt-Ampere CurvesFuel Consumption Curve shows typical fuel use under weld or power loadsDuty Cycle And Overheating This unit is rated for welding at 250 amperes continuously150 125 100 AC Generator Power CurveInstalling Welding Generator − InstallationLocation/Airflow Clearance Grounding1Supporting The Unit Mounting Welding GeneratorMounting Surface To Weld Unit In PlaceTools Needed 1/2 Installing Exhaust PipeStop engine and let cool Point exhaust pipe in desired diConnecting The Battery Activating The Dry Charge Battery If ApplicableDo not overfill battery cells Close door after connecting batteryEngine Prestart Checks Coolant Recovery TankFuel OilStick and TIG Welding Connecting To Weld Output TerminalsMIG and Fcaw Welding Stop engineStop engine Before Connecting to Weld Output terminals Selecting Weld Cable Sizes150 ft 200 ft 250 ft Socket Information Connecting To Remote 14 Receptacle RC14Welding Symbols Front Panel Controls See Section − Operating Welding GeneratorDescription Of Front Panel Controls See Section Process/Contactor Switch Settings Process/Contactor SwitchLift-Arc Start Method Touch Lift-ArcStart ProcedureDo not Strike Like a Match Lift-Arc t TIGRemote Voltage/Amperage Control Generator Power Receptacles − Operating Auxiliary EquipmentAt least once a month, run engine at Routine Maintenance − Maintenance & TroubleshootingMaintenance Label To clean air filter Servicing Air CleanerServicing Engine Cooling System Inspecting And Cleaning Optional Spark Arrestor MufflerMay affect engine warranty Adjusting Engine Speed On Standard ModelsMaximum Do not set engine speed higherWeld/Power Speed Adjustment Engine Speed AdjustmentEngine Speed No Load Rpm max 62.6 Hz 1500 rpm 50 HzTo change oil and filter Servicing Fuel And Lubrication SystemsTo replace primary canister fuel filter To drain water from fuel systemOverload Protection Replace Damaged Brushes Checking Generator BrushesVoltmeter/Ammeter Help Displays Help 20 DisplayHelp 25 Display Welding TroubleshootingEngine Generator PowerCheck for obstructed throttle solenoid Material Thickness Reference Chart Circuit Diagram For Welding Generator − Electrical Diagrams219 228−E − RUN-IN Procedure WetstackingWelding Generator From flammables Run-In Procedure Using Load BankOutput and do not exceed duty Cycle or equipment damage mayRun-In Procedure Using Resistance Grid − Generator Power Guidelines Selecting EquipmentGrounding Generator To Truck Or Trailer Frame How Much Power Does Equipment Require? Grounding When Supplying Building SystemsUse ground device as stated in electrical codes Amperes x Volts = WattsApproximate Power Requirements For Farm/Home Equipment Approximate Power Requirements For Industrial MotorsIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentHow Much Power Can Generator Supply? Power Required To Start MotorSingle-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 / Volts = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible 101 111 110 −3 109 108 −2 107 102 103 9897 104 106 105 − Parts List80Fig.12−4 66654243 TE1 Dia Part Description Quantity Mkgs Batt Panel, Front w/Components -1Item Panel, Front w/ComponentsFUEL/HM Control Panel Generator -1Item GeneratorRectifier Assembly Wiring Harnesses Service Your distributor also givesSupport Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s

Big Blue 300 specifications

The Miller Electric Big Blue 300 is a powerful and versatile engine-driven welder that has become a popular choice for professionals in various industries. Designed to excel in both welding and generator applications, the Big Blue 300 provides reliable performance, advanced technology, and exceptional durability, making it suitable for demanding work environments.

One of the standout features of the Big Blue 300 is its impressive output capabilities. With a maximum welding output of 300 amps, this machine can handle a wide range of welding applications, from stick to TIG and MIG processes. The dual voltage output allows for versatility in the field, accommodating both 120V and 240V power requirements, ensuring you can power tools and equipment directly from the welder.

The Big Blue 300 is equipped with Miller's innovative Clean Air Technology, which ensures that the engine operates efficiently and produces fewer emissions. This feature not only meets environmental standards but also enhances the longevity of the machine. The cooling system is engineered to maintain optimal operating temperatures, extending the life of the engine and related components.

For ease of use, the Big Blue 300 features an intuitive control panel with easy-to-read gauges and simple adjustment settings, allowing operators to quickly set welding parameters. The built-in Fuel Gauge and Hour Meter provide real-time information about fuel levels and usage, enabling efficient operation and maintenance planning.

Another notable characteristic of the Big Blue 300 is its rugged construction. Built to withstand harsh job site conditions, the machine features a durable frame and heavy-duty components that can endure the rigors of everyday use. The oversized wheels and solid axle design enhance portability, making it easy to transport across various terrains.

Additionally, the Big Blue 300 is designed for quiet operation, making it suitable for locations where noise levels are a concern. Its low decibel rating ensures that it won’t disturb the work environment, contributing to a more comfortable and productive atmosphere.

Overall, the Miller Electric Big Blue 300 is a robust engine-driven welder that combines power, efficiency, and portability. Whether working on construction sites, maintenance tasks, or fabrication projects, this machine delivers exceptional performance and reliability, making it a valuable tool for professionals who demand the best in their equipment.