Miller Electric Big 40 CAT manual Troubleshooting, Welding − CC Models

Page 56

9-10. Troubleshooting

A. Welding − CC Models

Trouble

Remedy

 

 

No weld output; generator power output

Check position of Ampere Range switch.

okay at ac receptacles.

 

 

 

 

Check position of optional Polarity switch.

 

 

 

Place Amperage Adjust switch in Panel position, or place switch in Remote position and connect remote

 

control to Remote Amperage Adjust receptacle RC13 (see Sections 5-10and 6-1).

 

 

 

Check and secure connections to Remote Amperage Adjust receptacle RC13 (see Section 5-10).

 

 

 

Check fuse F2, and replace if open (see Section 9-8). Have Factory Authorized Service Agent check inte-

 

grated rectifier SR2 and the rotor.

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings, and weld excitation circuit.

 

 

No weld output or generator power out-

Disconnect equipment from generator power receptacles during start-up.

put at ac receptacles.

 

 

 

 

Check fuses F1 and F2, and replace if open (see Section 9-8). Have Factory Authorized Service Agent

 

check integrated rectifier SR1, capacitor C9, integrated rectifier SR2, and the rotor.

 

 

 

Reset circuit breaker CB12. Have Factory Authorized Service Agent check diode D1 (see Section 9-8).

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings, and field excitation circuit.

 

 

Erratic weld output.

Check and tighten connections inside and outside unit.

 

 

 

Be sure connection to work piece is clean and tight.

 

 

 

Use dry, properly stored electrodes.

 

 

 

Remove excessive coils from weld cables.

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings.

 

 

High weld output.

Check engine speed, and adjust if necessary.

 

 

 

Have Factory Authorized Service Agent check OCV control circuit.

 

 

Low weld output.

Check engine speed, and adjust if necessary.

 

 

 

Check fuses F1 and F2, and replace if open (see Section 9-8). Have Factory Authorized Service Agent

 

check integrated rectifier SR1, capacitor C9, integrated rectifier SR2, and the rotor.

 

 

Electrode sticks to the workpiece more

Circuit breaker CB4 may be open. CB4 automatically resets when the fault is corrected (see Section 9-8).

frequently during low voltage (short arc

Have Factory Authorized Service Agent check transformer T1 and integrated rectifiers SR4 and SR5.

length) conditions.

 

 

 

Low open-circuit voltage.

Check engine speed, and adjust if necessary.

 

 

Maximum weld output only in each

Have Factory Authorized Service Agent check control relay CR7.

ampere range (with Stick/TIG Selection

 

switch in Stick position).

 

 

 

No remote fine amperage control.

Place Amperage Adjust switch in correct position.

 

 

 

Check and secure connections to Remote Amperage Adjust receptacle RC13 (see Section 5-10).

 

 

 

Reset circuit breaker CB11 (see Section 9-8). Have Factory Authorized Service Agent check control relay

 

CR7.

 

 

 

Repair or replace remote control device.

 

 

 

Have Factory Authorized Service Agent check OCV control circuit.

 

 

OM-4406 Page 50

Return To Table Of Contents

Image 56
Contents Description OM-4406Processes From Miller to You Table of Contents − Maintenance & Troubleshooting Deccon111/02 DirectivesStandards Sound Level Information Deccon1sound11/02Symbol Usage Arc Welding HazardsEngine Hazards Compressed Air Hazards Principal Safety Standards California Proposition 65 WarningsEMF Information Radiation can cause interferenceSignification des symboles − Consignes DE Sécurité − Lire Avant UtilisationUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in- cendie ou une explosion DES Particules Volantes peuvent blesser les yeuxDES Pièces Chaudes peuvent provoquer des brûlures graves LE Bruit peut affecter l’ouïe’EXPLOSION DE LA Batterie peut DES Organes Mobiles peuvent provoquer des blessuresLA Chaleur DU Moteur peut pro- voquer un incendie ’AIR Comprimé peut provoquer des blessuresPrincipales normes de sécurité Information sur les champs électromagnétiques− Definitions + − Starting InstructionsAre possible hazards as Can cause severe burns. DoFalling equipment can cause Serious injury and damageReturn To Table Of Contents Manufacturer’s Rating Labels For CE Products − 50 h StdStd CC Models CC/CV ModelsSymbols And Definitions Dimensions, Weights, And Operating Angles − SpecificationsWeld, Power, And Engine Specifications Volt-Ampere Curves For CC Models Stick Mode MIG ModeTIG Mode Volt-Ampere Curves For CC/CV ModelsFuel Consumption Duty Cycle And OverheatingAC Generator Power Curve Optional Three-Phase Generator Curves12 kVA/kW Single-Phase AC Output No Weld Load 15 kVA/kW Three-Phase AC Output No Weld LoadVolt-Ampere Curve For CC/CV Models In AC TIG Mode − Installation Installing Welding Generator See Sections 5-2AndLocation Grounding Airflow ClearanceUsing Lifting Eye Mounting Welding Generator Supporting The UnitMounting Surface To Bolt Unit In PlaceInstalling Exhaust Pipe Tools Needed 1/2Stop engine and let cool Point exhaust pipe in desired diActivating The Dry Charge Battery If Applicable Do not overfill battery cellsRead and follow all instruc ChargerConnect Negative − Cable Last Connecting The BatteryReinstall cover after connecting battery Coolant Recovery Tank Engine Prestart ChecksConnecting To Weld Output Terminals Selecting Weld Cable SizesConnecting To Remote 14 Receptacle RC14 On CC/CV Models Socket− Operating Welding Generator − CC Models Front Panel Controls For CC Models See SectionEngine Indicator Lights Do not switch under loadEngine Starting Controls To Start Do not use etherRemote Amperage Control On CC Models Optional Weld Control/Arc Condition Information LabelExample Set weld controls as shown toReturn To Table Of Contents − Operating Welding Generator − CC/CV Models Front Panel Controls For CC/CV Models See SectionEngine Oil Pressure Light Use switch to select weld amperage rangeVoltage/Amperage Adjust Switch And Remote 14 Receptacle Process/Contactor Switch On CC/CV Models Process/Contactor Switch SettingsExample Combination Remote Amperage Control TIG Remote Voltage/Amperage Control On CC/CV Models OptionalExample Combination Remote Amperage Control Stick − Operating Auxiliary Equipment Volt And 240 Volt ReceptaclesAt least once a month, run en Open, contact Factory AuthoClose panel opening if no connections are made to generator Three-Phase Power ConnectionRear Of Panel Circuit Breaker CB2 Circuit Breaker CB3 Optional Generator Power Receptacles240 V 15 a AC South African Receptacle RC1 − Maintenance & Troubleshooting Maintenance LabelRoutine Maintenance Every 8 hEvery 50 h Every 100 hService Every 1000 hEvery 2000 h Caterpillar Customer AssistanceServicing Air Cleaner By the warrantyTo clean air filter Do not clean housing with air hoseTools Needed 3/8 Inspecting And Cleaning Optional Spark Arrestor MufflerStop engine and let cool. Reinstall cleanout plug Adjusting Engine Speed Idle Speed AdjustmentWeld/Power Speed Adjustment Engine Speed No LoadServicing Fuel And Lubrication Systems Overload Protection Diagnosing Causes Of Engine Fault Shutdowns Pre-Start Diagnostic ChecksDiagnostic Checks While Running Start Engine With No Load AppliedTroubleshooting Welding − CC ModelsWelding − CC/CV Models Engine Standard Generator PowerOptional Three-Phase Generator Power CC/CV Models Wiring harness and components Shutdown switch is released OutTemperature is too high see Sections 5-7and Air in fuel system. See engine manual− Electrical Diagrams Circuit Diagram For CC Welding Generator215 296-B Circuit Diagram For CC/CV Welding Generator 215 297-B Welding Generator − RUN-IN ProcedureWetstacking Run-In Procedure Using Load Bank Procedure at less thanStop engine Do not touch hot exhaust From flammables Do not PerformRun-In Procedure Using Resistance Grid Bank/gridFrom flammables Do not perform run-in− Generator Power Guidelines Has this symbolSelecting Equipment Grounding Generator To Truck Or Trailer FrameGrounding When Supplying Building Systems How Much Power Does Equipment Require?Earth ground if supplying Use ground device as stated Electrical codesApproximate Power Requirements For Industrial Motors Approximate Power Requirements For Farm/Home EquipmentIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsPower Required To Start Motor How Much Power Can Generator Supply?Single-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible Current Load Watts Amperes113 108 100 CC only 119 110 109 111 -4 or − Parts List117 116 103 102 115 FIG 114 105 104 101 120 51 52 85 FigDia Part Description Quantity Dia Part Description Quantity Mkgs 095 Control Box Assembly − CC Models Control Box Assembly − CC/CV Models Control Box Assembly − CC/CV Models -1Item Panel, Front w/Components − CC Models MS1 Panel, Front w/Components − CC/CV Models Panel, Front w/Components − CC/CV Models -1ItemPC6 192 PLG6 Hardware is common Not available unless listed 34 36 27 26Main Rectifier Assembly -1Item Main Rectifier Assembly Page Your distributor also gives SupportMiller Electric Mfg. Co For assistance in filing or settling claims, contactYour distributor and/or equipment manufacturer’s Transportation Department