Miller Electric Big 40 CAT Every 1000 h, Every 2000 h, Caterpillar Customer Assistance, Service

Page 49

 

 

Every 1000 h

 

 

 

Check Radiator

 

 

Change Fuel

 

Fluid Level. See

 

 

Filters. See

 

Section 5-7.

 

 

Section 9-7.

 

Blow Out Or

 

 

Service Welding

OR

Vacuum Inside.

 

 

During Heavy

 

 

Generator Brushes And

 

 

 

 

Service,

 

Slip Rings. Service More

 

Clean Monthly.

 

Often In Dirty Conditions.*

 

Check

 

FUEL

Drain Sludge

 

Valve

SLUDGE

 

From Fuel

 

Clearance.*

 

Tank. See

 

 

 

 

Section 9-7.

 

 

Every 2000 h

 

 

 

 

Clean/Set Injectors.*

 

 

9-3. Caterpillar Customer Assistance

Service

When a problem arises concerning the operation or service of the engine, the problem will normally be managed by the dealer in your area.

Your satisfaction is a primary concern to Caterpillar and to Caterpillar dealers. If you have a problem that has not been handled to your complete satisfaction, fol- low these steps:

1 Discuss your problem with a manager from the dealership.

2 If your problem cannot be resolved at the dealer level without additional assistance, call a Field Service Coordinator at 1-800-447-4986.

3 If your needs still have not been met, submit the matter in writing to:

Caterpillar Inc.

Manager, Customer Service, Engine Division Mossville Bldg A

P.O. Box 600

Peoria, IL 61552-0600

Please follow the above steps in se- quence if a problem arises.

Website Address

www.caterpillar.com

Altitude

Contact the Caterpillar applications de- partment for information on the effect of ambient conditions on Caterpillar 3024 engines.

Return To Table Of Contents

OM-4406 Page 43

Image 49
Contents Processes OM-4406Description From Miller to You Table of Contents − Maintenance & Troubleshooting Standards DirectivesDeccon111/02 Deccon1sound11/02 Sound Level InformationArc Welding Hazards Symbol UsageEngine Hazards Compressed Air Hazards California Proposition 65 Warnings Principal Safety StandardsEMF Information Radiation can cause interference− Consignes DE Sécurité − Lire Avant Utilisation Signification des symbolesUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un in- cendie ou une explosionDES Pièces Chaudes peuvent provoquer des brûlures graves LE Bruit peut affecter l’ouïeDES Organes Mobiles peuvent provoquer des blessures ’EXPLOSION DE LA Batterie peutLA Chaleur DU Moteur peut pro- voquer un incendie ’AIR Comprimé peut provoquer des blessuresInformation sur les champs électromagnétiques Principales normes de sécurité− Definitions Starting Instructions + −Can cause severe burns. Do Are possible hazards asFalling equipment can cause Serious injury and damageReturn To Table Of Contents − 50 h Std Manufacturer’s Rating Labels For CE ProductsStd CC Models CC/CV ModelsSymbols And Definitions Weld, Power, And Engine Specifications − SpecificationsDimensions, Weights, And Operating Angles Volt-Ampere Curves For CC Models MIG Mode Stick ModeTIG Mode Volt-Ampere Curves For CC/CV ModelsDuty Cycle And Overheating Fuel ConsumptionOptional Three-Phase Generator Curves AC Generator Power Curve12 kVA/kW Single-Phase AC Output No Weld Load 15 kVA/kW Three-Phase AC Output No Weld LoadVolt-Ampere Curve For CC/CV Models In AC TIG Mode Installing Welding Generator See Sections 5-2And − InstallationLocation Grounding Airflow ClearanceUsing Lifting Eye Supporting The Unit Mounting Welding GeneratorMounting Surface To Bolt Unit In PlaceTools Needed 1/2 Installing Exhaust PipeStop engine and let cool Point exhaust pipe in desired diDo not overfill battery cells Activating The Dry Charge Battery If ApplicableRead and follow all instruc ChargerReinstall cover after connecting battery Connecting The BatteryConnect Negative − Cable Last Engine Prestart Checks Coolant Recovery TankSelecting Weld Cable Sizes Connecting To Weld Output TerminalsSocket Connecting To Remote 14 Receptacle RC14 On CC/CV ModelsFront Panel Controls For CC Models See Section − Operating Welding Generator − CC ModelsDo not switch under load Engine Indicator LightsEngine Starting Controls To Start Do not use etherWeld Control/Arc Condition Information Label Remote Amperage Control On CC Models OptionalExample Set weld controls as shown toReturn To Table Of Contents Front Panel Controls For CC/CV Models See Section − Operating Welding Generator − CC/CV ModelsVoltage/Amperage Adjust Switch And Remote 14 Receptacle Use switch to select weld amperage rangeEngine Oil Pressure Light Process/Contactor Switch Settings Process/Contactor Switch On CC/CV ModelsExample Combination Remote Amperage Control Stick Remote Voltage/Amperage Control On CC/CV Models OptionalExample Combination Remote Amperage Control TIG Volt And 240 Volt Receptacles − Operating Auxiliary EquipmentAt least once a month, run en Open, contact Factory AuthoRear Of Panel Three-Phase Power ConnectionClose panel opening if no connections are made to generator 240 V 15 a AC South African Receptacle RC1 Optional Generator Power ReceptaclesCircuit Breaker CB2 Circuit Breaker CB3 Maintenance Label − Maintenance & TroubleshootingEvery 8 h Routine MaintenanceEvery 50 h Every 100 hEvery 1000 h ServiceEvery 2000 h Caterpillar Customer AssistanceBy the warranty Servicing Air CleanerTo clean air filter Do not clean housing with air hoseStop engine and let cool. Reinstall cleanout plug Inspecting And Cleaning Optional Spark Arrestor MufflerTools Needed 3/8 Idle Speed Adjustment Adjusting Engine SpeedWeld/Power Speed Adjustment Engine Speed No LoadServicing Fuel And Lubrication Systems Overload Protection Pre-Start Diagnostic Checks Diagnosing Causes Of Engine Fault ShutdownsDiagnostic Checks While Running Start Engine With No Load AppliedWelding − CC Models TroubleshootingWelding − CC/CV Models Optional Three-Phase Generator Power CC/CV Models Standard Generator PowerEngine Shutdown switch is released Out Wiring harness and componentsTemperature is too high see Sections 5-7and Air in fuel system. See engine manualCircuit Diagram For CC Welding Generator − Electrical Diagrams215 296-B Circuit Diagram For CC/CV Welding Generator 215 297-B Wetstacking − RUN-IN ProcedureWelding Generator Procedure at less than Run-In Procedure Using Load BankStop engine Do not touch hot exhaust From flammables Do not PerformBank/grid Run-In Procedure Using Resistance GridFrom flammables Do not perform run-inHas this symbol − Generator Power GuidelinesSelecting Equipment Grounding Generator To Truck Or Trailer FrameHow Much Power Does Equipment Require? Grounding When Supplying Building SystemsEarth ground if supplying Use ground device as stated Electrical codesApproximate Power Requirements For Farm/Home Equipment Approximate Power Requirements For Industrial MotorsIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentHow Much Power Can Generator Supply? Power Required To Start MotorSingle-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 = Starting AmperageTypical Connections To Supply Standby Power Current Load Watts Amperes Selecting Extension Cord Use Shortest Cord Possible117 116 103 102 115 FIG 114 105 104 101 120 − Parts List113 108 100 CC only 119 110 109 111 -4 or 85 Fig 51 52Dia Part Description Quantity Dia Part Description Quantity Mkgs 095 Control Box Assembly − CC Models Control Box Assembly − CC/CV Models Control Box Assembly − CC/CV Models -1Item Panel, Front w/Components − CC Models MS1 Panel, Front w/Components − CC/CV Models -1Item Panel, Front w/Components − CC/CV ModelsPC6 192 PLG6 34 36 27 26 Hardware is common Not available unless listedMain Rectifier Assembly -1Item Main Rectifier Assembly Page Support Your distributor also givesFor assistance in filing or settling claims, contact Miller Electric Mfg. CoYour distributor and/or equipment manufacturer’s Transportation Department