Agilent Technologies 85036B, E manual Miscellaneous Items

Page 39

Replaceable Parts

Introduction

Table 6-3 Replaceable Parts—Items Not Included in the 85036B and 85036E Calibration Kits

Description

Qty

Agilent Part Number

 

 

 

Connector Gages (75Ω Type-N)

 

 

 

 

Connector gage set

1

85036B K01

 

 

 

Wrenches

 

 

 

 

 

3/4 in, 135 N-cm (12 in-lb) torque wrench

1

8710-1766

 

 

 

1/2 in and 9/16 in open-end wrench

1

8710-1770

 

 

 

3/4 in open-end wrench

1

8720-0011

 

 

 

ESD Protective Devices

 

 

 

 

 

Grounding wrist strap

1

9300-1367

 

 

 

5 ft grounding cord for wrist strap

1

9300-0980

 

 

 

2 ft by 4 ft conductive table mat with 15 ft grounding wire

1

9300-0797

 

 

 

ESD heel strap

1

9300-1308

 

 

 

Connector Cleaning Supplies

 

 

 

 

Isopropyl alcohol

30 ml

8500-5344

 

 

 

Foam tipped cleaning swabs

100

9301-1243

 

 

 

Miscellaneous Items

 

 

 

 

 

Connector care - quick reference card

1

08510-90360

 

 

 

85036B/E

6-5

Image 39
Contents Manufacturing Part Number Print Date June User’s and Service GuideDocumentation Warranty Contents Standard Definitions Replaceable PartsGeneral Information Calibration Kit Overview Kit ContentsAdapters Installation of the Calibration DefinitionsCalibration Definitions Equipment Required but Not SuppliedIncoming Inspection Calibration Kit Contents Recording the Device Serial Numbers Serial Number Record for 85036BSerial Number Record for 85036E Agilent 85036B kits with serial prefix 3103A and below Calibration Kits Documented in this ManualCalibration Kit History Agilent 85036B kits with serial prefix 3102A and belowPreventive Maintenance Clarifying the Sex of a ConnectorSpecifications Temperature-What to Watch Out For Environmental RequirementsEnvironmental Requirements Mechanical Characteristics Mechanical SpecificationsSupplemental Mechanical Characteristics Mechanical SpecificationsElectrical Specifications Electrical SpecificationsCertification Use, Maintenance, and Care of the Devices Electrostatic Discharge ESD Protection SetupInspect the Mating Plane Surfaces What Causes Connector Wear?Visual Inspection Look for Obvious Defects and Damage FirstCleaning Connectors Inspect the Precision Slotless Connectors femaleUse Compressed Air or Nitrogen Reinspect Clean the Mating Plane SurfacesPreliminary Connection How to Make a ConnectionFinal Connection Using a Torque Wrench ConnectionsWrench Positions Torque Wrench InformationUsing the Torque Wrench Connecting the Two-Piece Female Open How to Separate a ConnectionHandling and Storage Performance Verification How Agilent Verifies the Devices in This Kit IntroductionHow Often to Recertify Where to Send a Kit for RecertificationRecertification Limited RecertificationRecertification 85036B/E Troubleshooting Troubleshooting Flowchart Troubleshooting ProcessContacting Agilent Returning a Kit or Device to AgilentReturning a Kit or Device to Agilent 85036B/E Replaceable Parts Adapters Replaceable Parts for the 85036B Calibration KitReplaceable Parts for the 85036B Calibration Kit Replaceable Parts for the 85036E Calibration Kit Miscellaneous Items Introduction 85036B/E Standard Definitions Table A-1 Standard Class Assignments Standard Class AssignmentsTable A-2 Standard Class Assignments Blank Form Blank FormNominal Standard Definitions Setting the System ImpedanceStandard b Offset Freq Table A-3 Standard DefinitionsTable A-4 Standard Definitions Blank Form Index Index-2 85036B/E Calibration