440V Connection
To connect this machine to 440V
If you do not have
Note: When using a phase converter, the power from the manufactured power leg (sometimes called the wild wire) can fluctuate. Connect the manufactured power leg to the S terminal to pre- vent damage to the transformer. The wire from the S terminal can handle some fluctuation because it goes directly to the motor. The power going to the R and T terminals goes to the transformer and must be consistent to prevent damage.
To wire the sander to 440V:
1.DISCONNECT THE SANDER FROM THE POWER SOURCE!
2.Open the electrical box located on the back of the machine.
3.On the transformer, remove the wire labeled "1" connected to the 220V terminal, and connect it to the 440V terminal as shown in Figure 7.
� | � � | � � � � |
� � | � � � � | � � � � |
Figure 7. 440V connections, Model G0486/
G0487.
4.Refer to Figure 8 and find the power panel on your machine.
5.Swap out the applicable thermal relays and contactors from the conversion kit at the loca- tions shown in Figure 8, and set them to the overload values listed.
—For the G0486, use conversion kit #P04868139 and change out two relays.
—For the G0487, use conversion kit #P04878139. Change out two relays and change the two LC1-D40 sanding motor con- tactors with two LC1-D386 contactors.
G0486
| ||
Set to: | ||
Set to: | ||
| ||
Change Sanding Motor | ||
Contactors (G0487 only) |
G0487
| |
Set to: |
|
| |
| Set to: |
|