SECTION 3: CIRCUIT REQUIREMENTS
110 Volt
Amperage Draw
The Model G0547 1⁄3 HP motor is wired to oper- ate at 110V and will draw the following load:
Motor Load | 5 Amps |
Plug Type
The Model G0547 is supplied with a NEMA
i |
Figure 1. NEMA 5-15 plug and grounded outlet.
Circuit Breaker Requirements
We recommend that the circuit you use your machine on should be dedicated. Use the follow- ing guidelines when choosing a circuit breaker for your machine (circuit breakers rated any higher are not adequate to protect the circuit):
Recommended Circuit Breaker | 10 Amp |
Your Circuit Capacity
Always check to see if the wires in your circuit are capable of handling the amperage load from your machine. If you are unsure, consult a qualified electrician.
If you operate this machine on any circuit that is already close to its capacity, it might blow a fuse or trip a circuit breaker. However, if you are not placing an unusual load on the machine and a power failure still occurs, contact a qualified elec- trician or our Service Department at (570) 546- 9663.
Serious personal injury could occur if you connect your machine to the power source before you have completed the assembly process. DO NOT connect the machine to the power source until instructed to do so.
G0547 Combo Sander |