MANUAL VS. AUTOMATIC CHARGING
In the AUTOMATIC positions, the charger will only turn ON when it is connected to a battery with a voltage over .7 volts. In the MANUAL position, the charger will turn ON under any condition. If a battery is so depleted of charge that its voltage is less than
.7 volts, switch to the MANUAL position for a few minutes before switching to an AUTOMATIC position.
DELCO VOYAGERAND SIMILAR BATTERIES:
Some batteries, especially those with a
DESULFATION MODE
If your battery has been left discharged for an extended period of time, it may have become 'SULFATED'. If your battery voltage
is less than 12.2 volts prior to being charged, and the voltage climbs rapidly when you first start charging, your battery may be SUL- FATED. Under this condition, the charger enters DESULFATION MODE (if it is in anAUTOMATIC position). In DESULFATION MODE, the initial charging current is very small. The charger will stay in DESULFATION MODE for 10 hours, attempting to break down the sulfation. If the battery current increases to normal in this time, the charger will enter the normal AUTOMATIC MODE. If the current does NOT increase to normal, the charger will enter the ABORT state and will shut off. The ABORT state is indicated by all four LEDs flashing.
NOTE: A buzz or hum is normal when the output cables have been disconnected and the AC power cord is still connected to an electrical source (i.e. wall outlet).
These types of noises will also occur when the green light comes on indicating the battery is "Completely Charged". At this point, the charger has stopped charging the battery, but still hums or buzzes until the electrical power is shut off.
CIRCUIT BREAKER
This battery charger is equipped with a
NOTE: Clicking sound is normal. Wait until charger automatically resets itself.
CAUTION: Persistent clicking (more than 30 minutes) may indi- cate reverse connection or shorted battery cells. (See TROUBLE-
SHOOTING)
BATTERY TYPES
Three basic types of
(2) Maintenance Free, (3) Deep Cycle / Marine.
Conventional and Low Maintenance Batteries. These are the antimony/lead batteries. Conventional/Low Maintenance bat- teries require periodic addition of water to the acid solution (electrolyte). Additional water may be added by removing the filler caps located on the top of the battery.
IMPORTANT: When antimony is known to be one of the materi- als used in the battery's construction, that battery is a Low Main- tenance/Conventional type.
CAUTION: Some Low Maintenance batteries have a relatively smooth top without any apparent battery filler caps. If, however, the battery manufacturer/distributor recommends periodic
checking of electrolyte level and provides access to the battery for water additions, the battery is probably a Low Maintenance/Con- ventional type.
Maintenance Free Batteries. These are calcium/lead batteries and normally do not require water additions. Therefore, filler caps have been removed from the battery surface. These bat- teries will have a smooth or sealed appearance.
Deep Cycle Batteries. These heavy duty batteries are used in boats, construction equipment, sump pumps, etc. They are nor- mally marked DEEP CYCLE on the outside of the case.
OPERATING INSTRUCTIONS: CHARGING BATTERY OUT OF THE VEHICLE
When charging battery out of the vehicle, take care to determine the battery type. To reduce risk of a spark near battery, follow these steps when battery is outside vehicle. WARNING: A spark near battery may cause battery explosion. WARNING: When removing battery from vehicle or boat, disconnect grounded post first. When disconnecting, make sure all accessories are off, so as not to cause an arc. (NOTE: A marine (boat) battery must be removed and charged on shore. (To charge on board requires special equipment designed for marine use.) WARNING: When reinstalling battery, attach the ground post first.
4 |