5.PERFORMANCE CHARTS

(1)Operating Current

2 Indoor Unit: KS2462R

Outdoor Unit: CL2462R

Operating current characteristics versus outdoor ambient temperature and indoor temperature.

(Indoor relative humidity: 50%, Indoor fan speed: High)

230V

 

 

 

 

Outdoor fan speed

 

 

 

 

 

 

 

Low

 

Med

 

High

 

 

14

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

(A)

12

 

 

 

 

 

 

 

 

current

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating

10

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

23

32

41

50

59

68

77

86

95

 

(–5)

(0)

(5)

(10)

(15)

(20)

(25)

(30)

(35)

Outdoor ambient temp. °F (°C)

Indoor temp. °F (°C)

85 (30)

80 (27)

75 (24)

70 (21)

104

(40)

1063_X_S

208V

 

14

 

13

(A)

12

current

11

 

Operating

10

8

 

9

 

7

Outdoor fan speed

Low

Med

High

Indoor temp. °F (°C)

85 (30)

80 (27)

75 (24)

70 (21)

23

32

41

50

59

68

77

86

95

104

(–5)

(0)

(5)

(10)

(15)

(20)

(25)

(30)

(35)

(40)

Outdoor ambient temp. °F (°C)

1064_X_S

SM830092

– 18 –

Image 18 Contents
Technical Data Indoor Unit Outdoor Unit KS2462R C2462R CL2462RPlease Read Before Starting …In a Room…In Moist or Uneven Locations Table of Contents Operating Range KS2462R / C2462RKS2462R / CL2462R Specifications Unit SpecificationsIndoor Unit KS2462R Outdoor Unit CL2462R Major Component Specifications Indoor Unit Major Component Specifications Outdoor Unit Model No CL2462R Source Controller P.C.B. AssyHeat exchange Thermistor Coil sensor Other Component Specifications Indoor UnitModel No KS2462R Power Transformer Lamp AssyModel No C2462R Other Component Specifications Outdoor UnitPower Relay Thermostat Coil sensorModel No CL2462R Solenoid control valve or coilDimensional Data Indoor Unit KS2462R Outdoor Unit C2462R, CL2462R Cooling Capacity Indoor Unit KS2462R Outdoor Unit C2462R208V / 1 phase / 60Hz 230V Performance ChartsOperating Current Indoor Unit KS2462R 208VOutdoor Unit CL2462R 230V / 208 High and Low Pressure Indoor Unit KS2462RHigh Pressure Low Pressure230 AIR Throw Distance Chart Horizontal distance ftRefrigerant Flow Diagram HgbvInstallation Instructions Tubing LengthC2462R, CL2462R 132 Selecting the Installation Site For stable operationAir conditioner, do Air discharge chamber for top discharge Recommended outer dimensions of wind shield field supply Electrical Wiring General Precautions on Wiring Wiring System Diagram ModelsElectrical Data Electric Wiring Diagram Electrical Wiring DiagramsElectric Wiring Diagram Schematic Diagram CL2462R Outdoor Unit Controller CR-CL2432Schematic Diagram Outdoor Unit CL2462RRoom Temperature Control Processes and FunctionsDry Operation Dehumidification Cooling operation Dry a zoneFreeze Prevention Outdoor Fan Speed Control C2462R Type CL2462R TypeService Procedures 1032XS Check remote control unit There is a possibility of short circuitCheck Operation selector switch in the indoor unit Check compressor motor protectors High pressure switch 63PHTransformer in indoor unit Check. auxiliary relay Y or 2Y Check fuse on the P.C.B. Ass’y in the indoor unitCheck Cool / FAN selector switch in the remote control unit Check set temperatureOutdoor Unit does not Run Check compressor motor magnetic contactor Check indoor unit P.C.BCheck outdoor unit P.C.B. CL2462R Type Some Part does not Operate. A. Indoor fan does not run Indoor Unit does not RunIndoor fan and flap motor do not run Flap motor does not runOutdoor Fan does not Run Outdoor Fan does not Run for CL2462R Compressor does not RunPoor Cooling Excessive CoolingRoom temp. Sensor in the remote control unit is defective Power Supply Wires Measurement of Insulation Re- sistance for Electrical partsChecking the Protective Devices Compressor motor thermal protector . . . . . . Outdoor unitIndoor fan motor FMI Indoor unit Measure the coil resistance Motor capacitor Both in indoor and outdoor unitCheck for continuity using a multim- eter as shown in Fig Continuity of fuse on P.C.B. Ass’yMethod Used to Replace Fuse on PCB Ass’y Refrigerant R410A Special Precautions When Installing Unit No addition of compressor oil for R410A Gauge manifold