Sanyo C2462R Other Component Specifications Indoor Unit, Model No KS2462R Power Transformer

Page 10

2. SPECIFICATIONS

(3)Other Component Specifications

(A)Indoor Unit

 

MODEL No.

 

 

KS2462R

 

 

 

 

 

 

 

Power Transformer

 

 

ATR – T5

 

 

 

 

 

 

 

Rated

 

Primary

AC 230 V, 60 Hz

 

 

 

 

 

 

 

 

 

Secondary

AC19 V, 0.5 A

 

 

 

 

 

 

 

 

 

Capacity

9.5 VA

 

 

 

 

 

 

 

Coil resistance

 

Ω

Primary (WHT - WHT) : 457.5

 

(Ambient temprature 77 °F)

Secondary (BRN - BRN) : 3.9

 

 

 

 

 

 

 

Thermistor cut off temperature

 

277 °F

 

 

 

 

 

 

 

Thermistor (Coil sensor)

 

 

DTN - TKS131B

 

 

 

 

 

 

Coil resistance

 

kΩ

32 °F : 15.0 ± 2 %

 

 

 

 

 

 

Thermistor (Room sensor)

 

 

DTN - TKS128B

 

 

 

 

 

 

Coil resistance

 

kΩ

77 °F : 5.0 ± 3 %

 

 

 

 

 

 

Lamp Ass'y

 

 

IND - K301AH

 

 

 

 

 

 

Flap Motor

 

 

MP24GA2

 

 

 

 

 

 

SM830092

– 10 –

Image 10 Contents
Technical Data Indoor Unit Outdoor Unit KS2462R C2462R CL2462R…In a Room Please Read Before Starting…In Moist or Uneven Locations Table of Contents KS2462R / C2462R Operating RangeKS2462R / CL2462R Specifications Unit Specifications Indoor Unit KS2462R Outdoor Unit CL2462R Major Component Specifications Indoor Unit Major Component Specifications Outdoor Unit Controller P.C.B. Assy Model No CL2462R SourceHeat exchange Thermistor Coil sensor Other Component Specifications Indoor UnitModel No KS2462R Power Transformer Lamp AssyModel No C2462R Other Component Specifications Outdoor UnitPower Relay Thermostat Coil sensorModel No CL2462R Solenoid control valve or coilDimensional Data Indoor Unit KS2462ROutdoor Unit C2462R, CL2462R Cooling Capacity Indoor Unit KS2462R Outdoor Unit C2462R208V / 1 phase / 60Hz 230V Performance ChartsOperating Current Indoor Unit KS2462R 208VOutdoor Unit CL2462R 230V / 208 High and Low Pressure Indoor Unit KS2462RHigh Pressure Low Pressure230 AIR Throw Distance Chart Horizontal distance ftRefrigerant Flow Diagram HgbvTubing Length Installation InstructionsC2462R, CL2462R 132 For stable operation Selecting the Installation SiteAir conditioner, do Air discharge chamber for top discharge Recommended outer dimensions of wind shield field supply Electrical Wiring General Precautions on Wiring Wiring System Diagram ModelsElectrical Data Electric Wiring Diagram Electrical Wiring DiagramsElectric Wiring Diagram Schematic Diagram CL2462R Outdoor Unit Controller CR-CL2432Schematic Diagram Outdoor Unit CL2462RRoom Temperature Control Processes and FunctionsDry Operation Dehumidification Cooling operation Dry a zoneFreeze Prevention Outdoor Fan Speed Control C2462R Type CL2462R TypeService Procedures 1032XS Check remote control unit There is a possibility of short circuitCheck compressor motor protectors High pressure switch 63PH Check Operation selector switch in the indoor unitTransformer in indoor unit Check. auxiliary relay Y or 2Y Check fuse on the P.C.B. Ass’y in the indoor unitCheck set temperature Check Cool / FAN selector switch in the remote control unitOutdoor Unit does not Run Check indoor unit P.C.B Check compressor motor magnetic contactorCheck outdoor unit P.C.B. CL2462R Type Some Part does not Operate. A. Indoor fan does not run Indoor Unit does not RunIndoor fan and flap motor do not run Flap motor does not runOutdoor Fan does not Run Outdoor Fan does not Run for CL2462R Compressor does not RunPoor Cooling Excessive CoolingRoom temp. Sensor in the remote control unit is defective Power Supply Wires Measurement of Insulation Re- sistance for Electrical partsChecking the Protective Devices Compressor motor thermal protector . . . . . . Outdoor unitIndoor fan motor FMI Indoor unit Measure the coil resistance Motor capacitor Both in indoor and outdoor unitContinuity of fuse on P.C.B. Ass’y Check for continuity using a multim- eter as shown in FigMethod Used to Replace Fuse on PCB Ass’y Refrigerant R410A Special Precautions When Installing Unit No addition of compressor oil for R410A Gauge manifold