1-1 Unit Specifications

 

MODEL No.

 

Indoor Unit

 

 

 

 

KS2462R

 

 

 

 

Outdoor Unit

 

 

 

 

C2462R

 

 

POWER SOURCE

 

 

 

 

230 - 208 V / 1 Phase / 60 Hz

 

 

PERFORMANCE

 

 

 

 

 

Cooling

 

 

Capacity

 

BTU / h

 

27,000

 

26,000

 

 

 

 

 

kW

 

7.912

 

7.619

 

 

Air circulation (Hi)

 

Cu.ft. / min.

 

559

 

 

519

 

 

Moisture removal (High)

 

Pints / h

 

6.5

 

 

6.4

 

 

ELECTRICAL RATINGS

 

 

 

 

 

 

 

 

 

 

Voltage rating

 

 

VAC

 

230

 

 

208

 

 

Available voltage range

 

 

VAC

 

 

187 – 253

 

 

Running amperes*

 

 

A

 

10.2

 

 

10.9

 

 

Max. running amperes**

 

 

A

 

12.5

 

 

13.5

 

 

Power input

 

 

W

 

2,240

 

2,200

 

 

Power factor

 

 

%

 

95.5

 

 

97.0

 

 

S.E.E.R

 

BTU / Wh

 

13.0

 

 

13.0

 

 

Max. starting amperes

 

 

A

 

61

 

 

61

 

 

FEATURES

 

 

 

 

 

 

 

 

 

 

Controls

 

 

 

 

 

Microprocessor

 

 

Timer

 

 

 

 

ON/OFF 24-hours & Program

 

 

Fan speed Indoor / Outdoor

 

 

 

 

3 and Automatic control / 2 (Auto)

 

 

Air deflection

Horizontal / Vertical

 

 

– / Automatic

 

 

Air filter

 

 

 

 

 

Washable, easy access

 

 

Remote controller (Accessory)

 

 

 

 

RCS - 1PS4U - G

 

 

Refrigerant control

 

 

 

 

 

Capillary tube

 

 

Refrigerant tubing connections

 

 

 

 

Flare type

 

 

Compressor

 

 

 

 

 

Scroll

 

 

Operation sound

Indoor - Hi/Me/Lo

dB - A

 

 

48 / 42 / 38

 

 

 

 

Outdoor - Hi

dB - A

 

 

 

55

 

 

REFRIGERANT TUBING

 

 

 

 

 

 

 

 

 

 

Limit of tubing length

 

ft.

(m)

 

 

132 ( 40 )

 

 

Limit of tubing length at shipment

ft.

(m)

 

 

23 ( 7 )

 

 

Limit of elevation difference

 

ft.

(m)

 

 

50 ( 15 )

 

 

between the two units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant tube

Narrow tube

in. (mm)

 

 

3 / 8

(9.52)

 

 

outer diameter

Wide tube

in. (mm)

 

 

3 / 4

(19.05)

 

 

Refrigerant amount at shipment

lbs. (kg)

 

 

R410A - 6.6 (3)

 

 

DIMENSIONS & WEIGHT

 

 

 

 

Indoor unit

 

Outdoor unit

 

Unit dimensions

Height

in. (mm)

 

13

(330)

 

36-5/8

(930)

 

 

 

Width

in. (mm)

 

44-7/8

(1,140)

 

37

(940)

 

 

 

Depth

in. (mm)

 

8-31/32

(228)

 

13-3/8

(340)

 

Package dimensions

Height

in. (mm)

 

12-25/32

(325)

 

39-3/4

(1,010)

 

 

 

Width

in. (mm)

 

48-15/32

(406)

 

39-3/8

(1,000)

 

 

 

Depth

in. (mm)

 

15-31/32

(406)

 

15-3/4

(400)

 

Net weight

 

lbs. (kg)

 

40

(18)

 

150

(68)

 

Shipping weight

 

lbs. (kg)

 

44

(20)

 

190

(86.5)

 

Shipping volume

 

cu. ft.(m3)

 

5.7

(0.162)

 

14.1

(0.40)

Cooling:

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

 

 

 

 

 

 

 

 

 

 

Rating conditions (*) : Indoor air temperature 80 °F DB / 67 °F WB,

Outdoor air temperature 95 °F DB / 75°F WB

 

 

Full load conditions (**): Indoor air temperature 80 °F DB / 67 °F WB,

Outdoor air temperature 115 °F DB

 

SM830092

– 5 –

Image 5
Contents Indoor Unit Outdoor Unit KS2462R C2462R CL2462R Technical Data…In Moist or Uneven Locations Please Read Before Starting…In a Room Table of Contents KS2462R / CL2462R Operating RangeKS2462R / C2462R Unit Specifications SpecificationsIndoor Unit KS2462R Outdoor Unit CL2462R Major Component Specifications Indoor Unit Major Component Specifications Outdoor Unit Heat exchange Model No CL2462R SourceController P.C.B. Assy Model No KS2462R Power Transformer Other Component Specifications Indoor UnitThermistor Coil sensor Lamp AssyPower Relay Other Component Specifications Outdoor UnitModel No C2462R Thermostat Coil sensorSolenoid control valve or coil Model No CL2462RIndoor Unit KS2462R Dimensional DataOutdoor Unit C2462R, CL2462R Indoor Unit KS2462R Outdoor Unit C2462R Cooling Capacity208V / 1 phase / 60Hz Operating Current Indoor Unit KS2462R Performance Charts230V 208VOutdoor Unit CL2462R High Pressure High and Low Pressure Indoor Unit KS2462R230V / 208 Low Pressure230 Horizontal distance ft AIR Throw Distance ChartHgbv Refrigerant Flow DiagramC2462R, CL2462R 132 Installation InstructionsTubing Length Air conditioner, do Selecting the Installation SiteFor stable operation Air discharge chamber for top discharge Recommended outer dimensions of wind shield field supply Electrical Wiring General Precautions on Wiring Models Wiring System DiagramElectrical Data Electrical Wiring Diagrams Electric Wiring DiagramElectric Wiring Diagram Schematic Diagram Controller CR-CL2432 CL2462R Outdoor UnitOutdoor Unit CL2462R Schematic DiagramProcesses and Functions Room Temperature ControlCooling operation Dry a zone Dry Operation DehumidificationFreeze Prevention CL2462R Type Outdoor Fan Speed Control C2462R TypeService Procedures 1032XS There is a possibility of short circuit Check remote control unitTransformer in indoor unit Check Operation selector switch in the indoor unitCheck compressor motor protectors High pressure switch 63PH Check fuse on the P.C.B. Ass’y in the indoor unit Check. auxiliary relay Y or 2YOutdoor Unit does not Run Check Cool / FAN selector switch in the remote control unitCheck set temperature Check outdoor unit P.C.B. CL2462R Type Check compressor motor magnetic contactorCheck indoor unit P.C.B Indoor fan and flap motor do not run Indoor Unit does not RunSome Part does not Operate. A. Indoor fan does not run Flap motor does not runOutdoor Fan does not Run Compressor does not Run Outdoor Fan does not Run for CL2462RExcessive Cooling Poor CoolingRoom temp. Sensor in the remote control unit is defective Measurement of Insulation Re- sistance for Electrical parts Power Supply WiresCompressor motor thermal protector . . . . . . Outdoor unit Checking the Protective DevicesMotor capacitor Both in indoor and outdoor unit Indoor fan motor FMI Indoor unit Measure the coil resistanceMethod Used to Replace Fuse on PCB Ass’y Check for continuity using a multim- eter as shown in FigContinuity of fuse on P.C.B. Ass’y Refrigerant R410A Special Precautions When Installing Unit No addition of compressor oil for R410A Gauge manifold

C2462R, CL2462R specifications

The Sanyo CL2462R and C2462R are versatile and innovative air conditioning models designed to meet the demands of residential and commercial spaces. Known for their advanced features, energy efficiency, and user-friendly operation, these units have garnered a reputation for reliability and performance.

One of the standout features of the Sanyo CL2462R and C2462R is their energy efficiency. Equipped with inverter technology, these models adjust their cooling output based on the ambient temperature, minimizing energy consumption while maintaining consistent comfort levels. This not only helps in reducing electricity bills but also contributes to environmental sustainability, making them an attractive choice for the eco-conscious consumer.

Both models come with a powerful cooling capacity, ensuring rapid temperature reduction even in the most demanding conditions. The CL2462R features a robust compressor that provides an efficient cooling experience, while the C2462R balances power with refined performance, tailoring its output to the specific needs of the space it serves.

Another significant characteristic is their whisper-quiet operation. The Sanyo CL2462R and C2462R are designed with noise reduction technology, allowing them to operate at lower decibel levels. This feature makes them ideal for use in bedrooms, offices, or any quiet environment where disruption needs to be minimized.

User-centric design is prevalent in these models, with intuitive remote controls and programmable timers that allow users to customize their cooling experience. Both units feature multiple fan speeds, allowing users to choose their desired airflow levels for optimal comfort. Additionally, the units are equipped with air purification technologies, including filters that effectively trap dust, allergens, and pollutants, ensuring that the air circulated is clean and healthy.

The Sanyo CL2462R and C2462R also boast sleek designs that can complement various interior decor styles. Their compact dimensions make them easy to install without occupying too much space, making them a practical choice for modern living.

In summary, the Sanyo CL2462R and C2462R deliver exceptional performance, energy efficiency, and user-friendly features, making them ideal solutions for effective cooling. These models embody Sanyo's commitment to quality and innovation, providing consumers with reliable products that enhance comfort and improve air quality in any environment.