P 3/ 11
Repair
[3]DISASSEMBLY/ASSEMBLY
[3]-1. Housing
DISASSEMBLING
Fig. 2
1.Remove Clamp plate and Base from Housing set by unscrewing M4x16 Hex socket head bolt with Hex wrench 3.
2.Separate Housing R by unscrewing M4x35
Tapping screw (1pc.) and 4x18 Tapping screws (9pcs).
4x35 Tapping screw (1 pc.)
4x18 Tapping screw (9 pc.)
Housing R
M4x16 Hex socket head bolt
Base
Clamp plate
Hex wrench 3 (Standard equipment)
3. Remove Safety wire. | Safety wire |
|
ASSEMBLING
(1)Make sure to insert Holder to Housing L (Fig. 3).
Fig. 3
Note;
Before assembling Housing R, make sure that Holder (with M4 Screw hole) is mounted to Housing L
to fasten Housing set with M4x16 Hex socket head bolt
Holder
(2)Set Safety wire to Housing L (Fig.
(3)Assemble Housing R to Housing L (Fig.
(4)Assemble Base and Clamp plate to Housing set and tighten them with M4x16 Hex socket head bolt (Fig.