P 8/ 11
Circuit diagram
Fig. D-1
For the countries where the regulations for radio interference suppression are required.
Color index of lead wires' sheath Black
Red
Orange
Terminal
Switch
Line Filter
Red dot mark for + terminal
DC Motor
Wiring diagram
Connect Lead wires to Switch, DC motor and Terminal as described in Fig.
Fig. D-2
For the countries where the regulations for radio interference suppression are required.
Face the terminals of M1, M2 to Housing L side and connect Lead wires (orange) and (black) with terminals of Switch correctly in order to set Switch exactly in the Housing L.
Note; Do not overlap the Lead wires on the Switch body where they contact to Housing L.
Switch
| NG |
Housing | Housing |
L side | L side |
Connect Flag terminals of the Lead wires to terminals of DC motor and route the Lead wires through Line filter.
DC Motor
Handle side | Handle side |
Housing L side | Housing L side |
| NG |
| Red dot mark |
Line filter | Line filter |
Terminal
Lead wire (red)
Connect the Lead wire (red) at described direction.
Housing L side