Video Troubleshooting Table, continued
| SYMPTOM | CAUSE |
| REQUIRED ACTION |
| ||
|
|
|
|
| |||
|
|
|
| Check floppy drive for diskette. If you find disk, | |||
• VGM (video game machine) | Floppy disk in drive |
| eject it. Leave VGM power on. Turn off | ||||
| doesn’t appear |
|
| computer. Wait for hard disk to stop spinning. | |||
|
|
|
| Turn on computer. |
|
| |
• | No audio |
|
| Loosen computer case lid thumbscrews and lift | |||
|
| Faulty wiring |
| off cover. Assure that hard drive ribbon cable | |||
• |
|
| connector is fully seated into mating connector | ||||
|
|
|
| on motherboard. Check hard drive power cable. | |||
|
|
| 1. Verify that hard disk drive is correct for this | ||||
|
| Improper components |
| VGM. Label on drive records manufacturer | |||
|
|
|
| name, assembly number and program version. | |||
|
|
| 2. Verify that | circuit boards | are correct | for this | |
|
|
|
| VGM. Label on each board | records | ||
|
|
|
| manufacturer name, assembly number and | |||
|
|
|
| hardware version. |
|
| |
|
|
| 3. Verify that ROM instruction set is correct for this | ||||
|
|
|
| VGM. VGM set includes more than one ROM. | |||
|
|
|
| Label on each ROM records assembly number | |||
|
|
|
| and software version. |
|
| |
|
| Hard drive problems | 1. Turn computer on. Immediately look under hard | ||||
|
|
| drive. Hard Drive Activity LED flashes if drive is | ||||
|
|
|
| operating properly. |
|
| |
|
|
| 2. Allow VGM to load normally. Note and record | ||||
|
|
|
| any error messages that occur during | |||
|
|
| 3. Remove hard drive and install it in working VGM. | ||||
|
|
|
| If symptom recurs there, hard drive is faulty. | |||
|
|
|
| Replace it. |
|
|
|
|
| Picture tube aperture |
| Remove diskettes from room. Demagnetize | |||
• Blotches of color appear on | mask is magnetized |
| monitor with external degaussing coil. Take care | ||||
| screen |
|
| not to magnetize neighboring VGMs. Monitor | |||
|
|
|
| may be on or off for this procedure. |
| ||
|
|
| 1. | Turn on VGM. |
|
| |
• White areas in center of | Picture tube purity or | 2. | Press and hold TEST MODE to enter Menu | ||||
| screen appear tinged with | static convergence is |
| System. At Operator (Main) Menu, select | |||
| color | out of alignment |
| Diagnostic Menu. Then select Monitor Patterns | |||
|
|
|
| Menu. Run through Crosshatch, Red, Green and | |||
• Object edges have fringe of |
|
| Blue screens to find clearest display of problem. | ||||
| one or more colors |
| 3. | Display screen with greatest problem. |
| ||
|
|
| 4. Display Crosshatch Screen. Locate purity and | ||||
|
|
|
| static convergence ring magnets on back of | |||
|
|
|
| monitor neck. Watch screen in mirror. Adjust | |||
|
|
|
| magnets | to minimize | problem. | Follow |
|
|
|
| instructions from monitor manufacturer. |
| ||
|
|
| 5. | Display Crosshatch Screen. Touch up | |||
|
|
|
| adjustments while watching screen in mirror. |
CAUTION: Don’t operate the monitor without its Remote Adjustment Board.
WARNING: HANDLE FLUORESCENT TUBE AND CRT WITH CARE. If you drop a fluorescent tube or CRT and it breaks, it will implode! Shattered glass can fly eight feet or more from the implosion.
Troubleshooting