Miscellaneous Problem Troubleshooting Table
SYMPTOM | CAUSE |
| REQUIRED ACTION |
|
|
| |
|
| 1. Remove fluorescent tube from its sockets. If you | |
• Marquee lamp is intermittent | Faulty fluorescent |
| find cracks or darkened ends, install new lamp. |
or | tube |
| Clean tube. |
|
| 2. | Check continuity of both fluorescent tube |
• VGM (video game machine) |
|
| filaments. |
starts and plays normally |
| 3. | Verify that fluorescent tube operates by placing it |
|
|
| in working VGM. |
| Faulty lamp fixture |
| Verify that lamp pins make good connection with |
|
|
| socket contacts. |
| Faulty wiring |
| Measure fluorescent lamp AC voltages. Check |
|
|
| wiring and connector continuity from AC power |
|
|
| chassis to lamp assembly. |
|
| 1. Check bottom and rear of cabinet for blocked | |
• VGM operates normally | Obstructed fan |
| airflow. |
|
| 2. Move VGM away from sources of heat. | |
• Cabinet becomes warm after |
| 3. | Turn off VGM power. Remove dust from vent |
several hours of use |
|
| holes with |
| Faulty wiring |
| Check fan wiring and connectors. |
|
|
|
|
| Faulty fan |
| Check operation of all fans. |
|
|
| |
|
| 1. Check any assembly (RAM, ROM, Battery, etc.) | |
• Error messages appear on | Faulty hardware |
| identified in error messages. |
screen |
| 2. | Call your authorized distributor for help with |
|
|
| unresolved screen messages. |
Fan Location and Mounting
Troubleshooting