Wiring

Power supply

The CC-16 zone controller requires a minimum of 100mA at 8VDC. For convenience and consistency, we recommend you place the power supply in an equipment area adjacent to the network connection.

Power can be supplied over the network cable, from a power supply local to the unit, or from a remotely-located power supply with a separate cable run. The required cable AWG is dependent on the length of the run—the longer the run, the higher the voltage drop in the cable and the lower the required cable AWG.

Use the ControlSpace® accessory power supply or other suitable supply. Individual country requirements are:

North America: Power supplies used in North America must be NRTL listed and/or CSA certified Class 2 supplies, as appropriate. The supply must comply with one of the following UL standards: UL6500, UL60950, or UL1310.

Europe: Power supplies used in Europe must be in compliance with EN/IEC 60950 Clause 2.11.

Japan: Power supplies used in Japan must be in compliance with DENAN Law and be marked with the PSE diamond.

CAUTION: Never use more than one power supply on the same wire as this could cause slight differences in voltage that could damage the power supplies and/or the CC-16.

12

Image 12
Contents ControlSpace CC-16 Zone Controller Important Safety Instructions For the intended audienceInformation about products that generate electrical noise Please read this install guide Regulatory informationFeatures and functions IntroductionQuick start Installation CablingInstalling the mounting box Maximum cable distancesDIP Switch Settings DIP switch addressesTermination Wiring Connecting the wiresWiring Power supplyMounting Mounting the CC-16 zone controllerTroubleshooting Specifications Warranty Bose Product Sales ConditionsOther Rights Page