Bose CC-16 manual Maximum cable distances, Installing the mounting box

Page 8

Installation

Maximum cable distances

Wire Gauge/

 

Number of CC-16s

 

Power Supply Voltage

1

2

4

15

24 AWG 18V

2000 ft (610 m)

1852 ft (564 m)

926 ft (282 m)

247 ft (75 m)

 

 

 

 

 

24 AWG 12V

1481 ft (451 m)

741 ft (226 m)

370 ft (113 m)

99 ft (30 m)

 

 

 

 

 

24 AWG 9V

370 ft (113 m)

185 ft (56 m)

93 ft (28 m)

25 ft (7 m)

 

 

 

 

 

18 AWG 18V

2000 ft (610 m)

2000 ft (610 m)

2000 ft (610 m)

1010 ft (308 m)

 

 

 

 

 

18 AWG 12V

2000 ft (610 m)

2000 ft (610 m)

1515 ft (461 m)

404 ft (123 m)

 

 

 

 

 

18 AWG 9V

1515 ft (461 m)

758 ft (231 m)

379 ft (115 m)

101 ft (31 m)

 

 

 

 

 

Installing the mounting box

Install a dual-gang electrical box for each CC-16. Install the wall box so that it is flush or just below the surface of the finished wall. The unit is designed to fit in North American, Japanese, Australian and some European dual-gang electrical boxes. Mount the European and Australian double-gang boxes horizontally and the North American and Japanese boxes vertically as shown below.

Select a place that is convenient for the people who will be controlling the system. We suggest mounting the unit at eye-level for optimal LCD viewing angle.

CAUTION: Do not install the CC-16 in a box that has AC power (mains).

CAUTION: Do not place the power or network cables in the same conduit with the mains wire, unless you are sure that special regulatory insulation requirements are met. Consult your local electrical regulatory agency for further information.

8

Image 8
Contents ControlSpace CC-16 Zone Controller Important Safety Instructions For the intended audienceInformation about products that generate electrical noise Please read this install guide Regulatory informationFeatures and functions IntroductionQuick start Installation CablingInstalling the mounting box Maximum cable distancesDIP Switch Settings DIP switch addressesTermination Wiring Connecting the wiresWiring Power supplyMounting Mounting the CC-16 zone controllerTroubleshooting Specifications Warranty Bose Product Sales ConditionsOther Rights Page