Installation and
Calibration
As protection against feedback, the TAPE and VCR1 inputs are normally blocked from being used as sources for the Record and Zone 2 outputs. This default condition can be changed in the Input Configuration menu as follows.
Use MENU ▲ and ▼ to select REC/ZONE 2, then press SELECT. The MENU ▲ and ▼ buttons will select ANALOG, DIGITAL, or BLOCKED as the state of the input.
ANALOG allows maximum flexibility by utilizing both the digital and analog connections of a digital source component (provided both are connected). The
DIGITAL routes the digital signal, assigned to the input, to the
BLOCKED simply blocks the input from being sent to the Record and Zone 2 outputs. This prevents feedback from occurring with devices that have both an input and output attached to the
The remote control can be placed into an exclusive Record/Zone 2 control mode during normal operation by holding down ACCY and pressing RECORD/ZONE 2. This will display the message:
ZONE 2 IR REMOTE
MODE ENABLED
In this mode, the Volume, Mute, Input selection and L/R Balance controls will directly control the Zone 2 outputs with no effect on the Main outputs. Pressing any other keys will display the message:
ZONE 2 MODE ENABLED
KEY INVALID
To exit Zone 2 Remote mode and return the remote control to normal operation, press and hold ACCY, then press SELECT. The message:
NORMAL IR REMOTE
MODE ENABLED
will be displayed to confirm that normal operation has been restored.
NOTE: Removing the block from any input which has both an input and output attached may cause damaging feedback.
Zone 2 Remote Control
19