Siemens SINVERT 350 manual Tables, Figures

Page 5

Tables

 

Table 3-1 Pin assignment X5 (SUB-D 9-pin/ RS422 for PPsolar)

13

Table 4-1 Alarm and fault messages

27

Table 4-2 ISO fault

30

Table 4-3 Fault 0

31

Table 4-4 Faults 1 and 33

31

Table 4-5 Faults 4 and 47

32

Table 4-6 Fault 6

32

Table 4-7 Fault 12

32

Table 4-8 Fault 14

32

Table 4-9 Fault 36

33

Table 4-10 Fault 37

33

Table 4-11 Fault 39

34

Table 4-12 Fault 40

34

Table 4-13 Fault 43

35

Table 4-14 Fault 48

35

Table 4-15 Fault 62

35

Table 4-16 Fault 63

36

Table 4-17 Fault 64

36

Table 4-18 Fault 65

36

Table 4-19 Fault 91

37

Table 4-20 Fault 92

37

Table 4-21 Fault 93

37

Table 4-22 Fault 94

38

Table 4-23 Fault 95

38

Table 4-24 Fault 96

39

Table 4-25 Fault 97

39

Table 4-26 Fault 98

39

Figures

 

Figure 1-1 SINVERT 350/420/500 TL

6

Figure 2-1 Overview of PV system

8

Figure 3-1 Front view of control panel

12

Figure 3-2 Front view of control panel

13

Figure 3-3 Fast ON button and local/remote selector switch

14

Figure 3-4 Main menu PPsolar

17

Figure 3-5 System Diagram PPsolar

18

Figure 3-6 Control Panel PPsolar

19

Figure 3-7 Oscilloscope function PPsolar

20

Figure 3-8 Process Data window PPsolar

21

Figure 3-9 Data Storage PPsolar

24

Figure 3-10 Analysis window PPsolar

25

Image 5
Contents Sinvert Photovoltaic Qualified personnel Safety instructionsProper handling TrademarksContents Figures TablesScope of validity IntroductionAbout this documentation Target group Chapter ContentsDocument structure HistoryApplication DescriptionFive safety rules in Germany Instructions and safety informationHardware operation Commissioning the inverterSwitching off and disconnecting the power supply Switching on Operator panel Operating the inverterPin Signal Local/Remote selector switch Operating modeSwitching the inverter on and off Displaying currently active alarms and faults Fault resetAdjusting the voltage Grid LED indicator barAutomatic mode / Test mode Maximum Power Point LED MPPFault display Standby operation LED Standby1 WEB’log Communication with the inverterWinCC PPsolarRed System components are malfunctioning Control Panel PPsolar Oscilloscope function PPsolar Device Information SINVERT-SettingsActual values Actual Value SummaryMains Interface Weather conditionsPV Generator Data Storage PPsolar Energy10 Analysis window PPsolar Fault handling Alarm and fault messagesFault types Fault display / messagesMain cause Alarm and fault messagesMeaning Category LED Differences in potential in the PV field Faults Causes/diagnostics/remedial measuresMeasures DiagnosticsCauses Condition Fault in measured-value sensingCauses Cooling system is not working properly Heat generation is exceeding toleranceCauses Inlet air temperature too high No checkback signal from the AC contactor Causes No power supply for Fast OFFCauses No line voltage for Fast OFF Causes Measured DC voltage is too high13 Fault Alarm Vce monitor has responded 16 Fault Alarm Direct current too high Causes Contact in the signaling circuit is open Remedial Possible24 Fault Alarm Grid voltage outside tolerance Alarm without fault Contact addresses SupportGermany
Related manuals
Manual 42 pages 49.56 Kb

350, SINVERT 350 specifications

The Siemens SINVERT 350 series is a high-performance, lightweight inverter system designed to optimize energy conversion in solar power applications. With a power rating of up to 350 kW, this inverter model is tailored for large-scale photovoltaic installations and commercial applications. Its key features and technological innovations make it a valuable addition to any renewable energy project.

One of the main features of the SINVERT 350 is its advanced grid management capability. The inverter is equipped with sophisticated monitoring systems that ensure compliance with various grid connection standards, enhancing stability and reliability for the operator. This ensures seamless integration with existing power grids while optimizing energy yield. Additionally, it supports various grid support functionalities, helping maintain grid stability during high-demand periods.

Another notable characteristic is its modular design. The SINVERT 350 allows for easy integration with other units, scaling effectively to meet the power needs of larger installations. This modularity not only enhances flexibility but also simplifies maintenance and reduces operational costs over time. Each unit can be easily accessed, which minimizes downtime during servicing.

The SINVERT 350 also features advanced cooling technology. With its robust thermal management system, the inverter operates efficiently even under high temperatures, ensuring longevity and reliability. The design minimizes losses due to heat, effectively enhancing the overall energy conversion efficiency.

In terms of safety, the SINVERT 350 is built with integrated protection mechanisms, including over-voltage and short-circuit protections. These safety features safeguard both the inverter and the connected photovoltaic modules, ensuring a secure operating environment.

Another highlight is the inverter’s compatibility with the Siemens Smart Grid solutions. This integration means users can access comprehensive monitoring and analytics tools, enabling real-time performance tracking and optimization of energy output. With built-in web-based connectivity, operators can manage the system remotely, gaining insights and facilitating proactive maintenance.

In conclusion, the Siemens SINVERT 350 series combines robust performance, innovative technologies, and reliable safety features to create a compelling choice for large-scale solar energy projects. Its advanced design ensures operational efficiency and adaptability, thereby enhancing the overall viability of solar energy as a sustainable power source.