HP manual VA7410 Rail Kits, Product Option Description Number, VA7410 Enterprise Modules

Page 17

Chapter 4

Peripherals and Accessories

Product

Option

Description

Number

 

 

C7525A

 

Fiber Optic Cable 162-meters LC Duplex 50/125 M/M

C7526A

 

Fiber Optic Cable 502-meters LC Duplex 50/125 M/M

C7527A

 

Fiber Optic Cable 2002-meters LC Duplex 50/125 M/M

C7529A

 

2-meter FC fiber optic cable M/M duplex LC-SC

C7530A

 

16-meter FC fiber optic cable M/M duplex LC-SC

C7534A

 

FC fiber optic coupler F/F SC-SC

C7540A

 

FC adapter kit (includes C7529A and C7534A)

VA7410 Enterprise Modules

A6267AE

 

VA7410 with Dual Controller 1024-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (1) DIMM

 

 

512-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit, RS-

 

 

232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and cache

 

 

and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power

 

 

supplies, filler panels for controllers and disks.

A6268AE

 

VA7410 with Dual Controller 2048-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (2) DIMM

 

 

1024-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit,

 

 

RS-232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and

 

 

cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power

 

 

supplies, filler panels for controllers and disks.

A6187B

 

1×1024-MB Cache for Virtual Array Controller, 1×1024 2MB DIMM, StorageWorks VAP requires equal cache for both

 

 

Controllers (if 2nd installed). Order 1 per installed VAP

A6218A

 

VA7410 Controller (minimum two required for VA7410)

A6191A

 

Enterprise Class 18-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)

A6192A

 

Enterprise Class 36-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)

A6193A

 

Enterprise Class 36-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)

A6194A

 

Enterprise Class 73-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)

A7288A

0D1

Enterprise Class 73-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410 only)

A7289A

0D1

Enterprise Class 146-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410

 

 

only)

C7524A

 

Fiber Optic Cable 2-meters LC 50/125 M/M

C7525A

 

Fiber Optic Cable 16-meters LC Duplex 50/125 M/M

C7526A

 

Fiber Optic Cable 50-meters LC Duplex 50/125 M/M

C7527A

 

Fiber Optic Cable 200-meters LC Duplex 50/125 M/M

C7529A

 

2-meter FC fiber optic cable M/M duplex LC-SC

C7530A

 

16-meter FC fiber optic cable M/M duplex LC-SC

C7534A

 

FC fiber optic coupler F/F SC-SC

C7540A

 

FC adapter kit (includes C7529A and C7534A)

VA7410 Rail Kits

The following rail kits are needed to mount the VA7400 into the specific racks as listed.

Part Number

Description

A6209A

System/E Rail Kit (RoseBowl 2)

A6496A

NTRittal Rack Rail Kit

A6244A

HP Original rack rackmount hardware kit

HP e3000 Business Servers Configuration Guide – Effective 1/04

4-107

Information Subject to Change

 

Image 17
Contents Overview IntroductionVA7110 Overview VA7410 Overview Http//partner.americas.hp.com Important VA7410/DS2405 Notes Product FeaturesNew Firmware Revision Code Designation for VA7410 VA7110 Disk Enclosure Specifications DS2405 Instant Support Enterprise Edition Support Isee WarrantySpecifications VA7110 and VA7410 Controller Enclosure Specifications Temperature To 35 C 41 to 95 F DS2405 Disk Enclosure Specifications10% to 90% @ 28 C dry bulb Shock 11 ms half sine Vibration Rms, 5- to 500-Hz random1.1 HP StorageWorks Virtual Array 7000 Family Front View Fibre AC PowerPort ArrayVA7100 Hardware Ordering Information Hardware Ordering InformationDescription VA7100 Field RK SKUDisks VA7100 Factory RackA6183AE Deskside cabinet for HP StorageWorks VA7100VA7110 Hardware Ordering Information VA7100 Rail KitsPart Number Description VA7110 Field RK SKUVA7110 Rail Kits VA7410 Enterprise Factory Rack VA7410 Controller Enclosure Hardware Ordering InformationVA7410 Enterprise Modules VA7410 Rail KitsProduct Option Description Number Disk System Enclosure DS2405 Hardware Ordering Information DS2405 Disk System AccessoriesVA7000 Family Racking and Rail Kit Options Support Options OverviewPart Number Description Height Units 9122 Rack Meters 22U 9136 36U 9142 42UIndirect Commercial Support Packs VA Hardware Description 3-year Installation Year Support SDSupport SD, 24×7 24×7 Start-Up NumbersCode Description Hardware and Software-Additional Recommended ServicesDescription of Services Offered Disk Drives BatteryEarly Warning Switch Drive size GB 36 GB 73 GB Hot Spares Number of drives Loading RulesEstimated Usable Capacity for AutoRAID-VA7100 Estimated Usable Capacity for AutoRAID-VA7110 Estimated Usable Capacity for RAID 1+0-VA7110Drive size GB 36 GB 73 GB 146 GB Hot Spares Capacity in GBGbic VA7100 only Redundant Power Supply and Fan ModulesMidplane LED Status IndicationsArray Logs Supported Operating SystemsHub Support Supported Hardware DevicesHBA Support Supported Disk Drives Switch SupportSupported Fibre Channel Cables Part Number Description All Operating SystemsFront End and Back End Cabling ConfigurationSAN Definitions Long-Distance Configurations Not supported on MPE/iXController MPESwitch Dual HBA Dual controllers Management Station required SAN ConfigurationsWindows Server SwitchBuilding Cable/Connection LegendFibre channel short-wave optical only LAN connection Native Fibre ChannelSoftware Product Descriptions Software Products Reference ChartSoftware Products Software Product Source DescriptionHP StorageWorks Command View SDM Software Compatibility HP StorageWorks Command View SDM SoftwareOperating System Memory Video Disk Space2Disks Fans HP StorageWorks Command View SDM Frequently Asked QuestionsComponent HP StorageWorks Integrations Pack Compatibility HP StorageWorks Integrations Pack FeaturesHP StorageWorks Integrations Pack HP StorageWorks Business Copy VA HP StorageWorks Business Copy VA FeaturesHP StorageWorks Business Copy VA Software Compatibility Memory Disk SpaceHP StorageWorks Secure Manager VA HP StorageWorks Business Copy VA Frequently Asked QuestionsHP StorageWorks Secure Manager VA Features HP StorageWorks Auto Path HP StorageWorks Secure Manager VA Software CompatibilitySee above Solaris 2.6, 7.0, 8.0 See above Novell Netware 5.0,5.1HP StorageWorks Auto Path Frequently Asked Questions HP StorageWorks Auto Path FeaturesHP StorageWorks Auto Path Operating Systems Compatibility HP StorageWorks Auto Path Software CompatibilityOption Description HP StorageWorks Fast Recovery Solutions FeaturesVA7000 Family Software Ordering Information Required One software support warranty option requiredSoftware support warranty option required Enablement One 1 software support warranty option requiredProduct Number Option Description Option requiredUnlimited Warranty option requiredCapacity unlimited Abbreviation Description Glossary