HP VA7410 manual Loading Rules, Drive size GB 36 GB 73 GB Hot Spares Number of drives

Page 23

Chapter 4

Peripherals and Accessories

The disk drives provide the storage medium for the disk array. A minimum of four disk modules is required to operate the disk array. Different capacity disk modules can be installed in the same array. A new disk can be added at any time, even while the disk array is operating. The array controller will recognize that a new disk has been added and will include the disk in the array configuration automatically if the Auto Include feature is enabled. To make the additional capacity available to the host, a new logical drive must be created, and the resulting drive must be configured into the operating system.

Loading Rules

VA7100

Four (4) disks minimum and fifteen (15) disks maximum (4 of each type)

VA7110

Four (4) disks minimum and forty five (45) disks maximum (4 of each type)

VA7410 disk loading rules:

Ten (10) disk minimum per VA7410

One hundred and five (105) disks maximum

Four (4) disks minimum for each disk type that is installed, then user can add singles after that.

DS2405 (disk enclosure) disk loading rules:

Two (2) disk minimum

Fifteen (15) disk maximum per DS2405

Estimated Usable Capacity Tables

Estimated Usable Capacity for RAID 1+0—VA7100

This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7100 with 36- and 73-GB drives with or without the use of hot spare drives.

Capacity Table 1 GB = (1024)3 for RAID 1+0

Drive size (GB)

36 GB

36 GB

73 GB

73 GB

Hot Spares

2

0

2

0

Number of drives

Maximum usable capacity

Maximum usable capacity

Maximum usable capacity

Maximum usable capacity

 

in GB

in GB

in GB

in GB

4

30.0

63.3

63.4

130.2

5

45.2

80.0

95.4

163.6

6

63.3

96.7

130.2

197.1

7

80.0

113.4

163.6

230.5

8

96.7

130.1

197.1

263.9

9

146.8

146.8

297.3

297.3

10

163.4

163.4

330.7

330.7

11

180.1

180.1

364.1

364.1

12

196.8

196.8

397.5

397.5

13

213.5

213.5

431.0

431.0

14

230.2

230.2

464.4

464.4

15

246.9

246.9

497.8

497.8

HP e3000 Business Servers Configuration Guide – Effective 1/04

4-113

Information Subject to Change

 

Image 23
Contents Overview IntroductionVA7110 Overview VA7410 Overview Http//partner.americas.hp.com Important VA7410/DS2405 Notes Product FeaturesNew Firmware Revision Code Designation for VA7410 VA7110 Disk Enclosure Specifications DS2405 Instant Support Enterprise Edition Support Isee WarrantySpecifications VA7110 and VA7410 Controller Enclosure Specifications Shock 11 ms half sine Vibration Rms, 5- to 500-Hz random DS2405 Disk Enclosure SpecificationsTemperature To 35 C 41 to 95 F 10% to 90% @ 28 C dry bulb1.1 HP StorageWorks Virtual Array 7000 Family Front View Array AC PowerFibre PortVA7100 Field RK SKU Hardware Ordering InformationVA7100 Hardware Ordering Information DescriptionDeskside cabinet for HP StorageWorks VA7100 VA7100 Factory RackDisks A6183AEVA7110 Field RK SKU VA7100 Rail KitsVA7110 Hardware Ordering Information Part Number DescriptionVA7110 Rail Kits VA7410 Enterprise Factory Rack VA7410 Controller Enclosure Hardware Ordering InformationVA7410 Enterprise Modules VA7410 Rail KitsProduct Option Description Number Disk System Enclosure DS2405 Hardware Ordering Information DS2405 Disk System Accessories9122 Rack Meters 22U 9136 36U 9142 42U Support Options OverviewVA7000 Family Racking and Rail Kit Options Part Number Description Height Units24×7 Start-Up Numbers VA Hardware Description 3-year Installation Year Support SDIndirect Commercial Support Packs Support SD, 24×7Code Description Hardware and Software-Additional Recommended ServicesDescription of Services Offered Disk Drives BatteryEarly Warning Switch Drive size GB 36 GB 73 GB Hot Spares Number of drives Loading RulesEstimated Usable Capacity for AutoRAID-VA7100 Capacity in GB Estimated Usable Capacity for RAID 1+0-VA7110Estimated Usable Capacity for AutoRAID-VA7110 Drive size GB 36 GB 73 GB 146 GB Hot SparesLED Status Indications Redundant Power Supply and Fan ModulesGbic VA7100 only MidplaneArray Logs Supported Operating SystemsHub Support Supported Hardware DevicesHBA Support Part Number Description All Operating Systems Switch SupportSupported Disk Drives Supported Fibre Channel CablesFront End and Back End Cabling ConfigurationSAN Definitions Long-Distance Configurations Not supported on MPE/iXController MPESwitch Dual HBA Dual controllers Management Station required SAN ConfigurationsWindows Server SwitchNative Fibre Channel Cable/Connection LegendBuilding Fibre channel short-wave optical only LAN connectionSoftware Product Source Description Software Products Reference ChartSoftware Product Descriptions Software ProductsMemory Video Disk Space2 HP StorageWorks Command View SDM SoftwareHP StorageWorks Command View SDM Software Compatibility Operating SystemDisks Fans HP StorageWorks Command View SDM Frequently Asked QuestionsComponent HP StorageWorks Integrations Pack Compatibility HP StorageWorks Integrations Pack FeaturesHP StorageWorks Integrations Pack Memory Disk Space HP StorageWorks Business Copy VA FeaturesHP StorageWorks Business Copy VA HP StorageWorks Business Copy VA Software CompatibilityHP StorageWorks Secure Manager VA HP StorageWorks Business Copy VA Frequently Asked QuestionsHP StorageWorks Secure Manager VA Features See above Novell Netware 5.0,5.1 HP StorageWorks Secure Manager VA Software CompatibilityHP StorageWorks Auto Path See above Solaris 2.6, 7.0, 8.0HP StorageWorks Auto Path Software Compatibility HP StorageWorks Auto Path FeaturesHP StorageWorks Auto Path Frequently Asked Questions HP StorageWorks Auto Path Operating Systems CompatibilityOption Description HP StorageWorks Fast Recovery Solutions FeaturesVA7000 Family Software Ordering Information Required One software support warranty option requiredOption required Enablement One 1 software support warranty option requiredSoftware support warranty option required Product Number Option DescriptionUnlimited Warranty option requiredCapacity unlimited Abbreviation Description Glossary