HP VA7410 manual Battery, Early Warning Switch, Disk Drives

Page 22

Chapter 4

Peripherals and Accessories

In a dual controller configuration, both controllers must have the same amount of cache memory as the contents of NVRAM are mirrored between the two controllers. This mirroring process insures that both controllers have exactly the same information in the event of a failure. The controller battery maintains NVRAM contents when normal power is not present. If the battery fails or loses its charge while power is off, the NVRAM contents are lost on that controller. To protect against data loss, the array power/standby switch turns off power to the array and the “Shutdown Operation” copies NVRAM contents to the disk drives in slots 1 and 2 of the array. This allows reconstruction of the data in NVRAM if the original data is lost or corrupted.

Note: When upgrading a VA7400 to a VA7410 or a VA7100 to a VA7110 or a VA7410, both DIMMs need to be the same part number (A6186-60002, for example).

Note: The process of copying the contents of NVRAM to the two recovery disks makes the disk set independent of its controller. Because all the necessary mapping information is on these disks, it is possible to install a new controller or move the entire disk set to another controller. The new controller will determine that it has a new disk set, and the controller will attach itself to those disks.

DIMM Sizes and Cache Sizes

Array

Minimum Cache

Maximum Cache

VA7100

256-MB/controller

1024-MB/controller

VA7110

1024-MB/controller

2048-MB/controller

VA7410

1024-MB / controller

2048-MB / controller

Configurations of only one size DIMM in controllers are

supported (for example, mixing 512-MB and 1024-MB DIMMs in the same controller is not supported).

Slot 1 DIMM (MB)

Slot 2 DIMM (MB)

Total Memory (MB)

VA7100

VA7110

VA7410

256-MB

256-MB

Y

N

N

256-MB

256-MB

512-MB

Y

N

N

512-MB

512-MB

Y

N

N

512-MB

512-MB

1024-MB

Y

Y*

Y*

1024-MB

1024-MB

Y

Y

Y

1024-MB

1024-MB

2048-MB

N

Y

Y

* This is a supported configuration, but new VA7110 controllers will not ship with 512-MB DIMMs.

Battery

Each array controller includes one battery to supply backup power to the DIMMs in the event have a power failure or if array power is switched off. If power is lost, the BATTERY LED will flash with a 5% duty cycle while it powers the DIMMs. The battery will maintain a charge for 3.5 days. If the battery loses its charge, or if it is removed from the controller, the DIMMs have no power and NVRAM contents are lost. A battery should be replaced when the software indicates a battery has failed.

Early Warning Switch

In a dual controller configuration, the NVRAM contents on both controllers are updated constantly. By maintaining a mirror image of the NVRAM, the secondary controller can take over immediately if the primary controller fails. If a dual controller needs to be replaced online, an early warning switch incorporated into the latch detects when the controller is being removed. Releasing the latch disables communication between controllers before power is lost to the controller being removed. This prevents corruption of the NVRAM contents.

Disk Drives

The array must have a minimum of four disk drives installed. Several types of disk drives can be installed in the array and capacities can be mixed within the array:

18-GB Low-Profile Fibre Channel 15,000 rpm (supported, but no longer orderable)

36-GB Low-Profile Fibre Channel 10,000 rpm

36-GB Low-Profile Fibre Channel 15,000 rpm

73-GB Low-Profile Fibre Channel 10,000 rpm

73-GB Low-Profile Fibre Channel 15,000 rpm

146-GB Low-Profile Fibre Channel 10,000 rpm (VA7410 and VA7110 arrays only)

4-112

HP e3000 Business Servers Configuration Guide – Effective 1/04

 

Information Subject to Change

Image 22
Contents Introduction OverviewVA7110 Overview VA7410 Overview Http//partner.americas.hp.com New Firmware Revision Code Designation for VA7410 Product FeaturesImportant VA7410/DS2405 Notes VA7110 Disk Enclosure Specifications DS2405 Specifications WarrantyInstant Support Enterprise Edition Support Isee VA7110 and VA7410 Controller Enclosure Specifications 10% to 90% @ 28 C dry bulb DS2405 Disk Enclosure SpecificationsTemperature To 35 C 41 to 95 F Shock 11 ms half sine Vibration Rms, 5- to 500-Hz random1.1 HP StorageWorks Virtual Array 7000 Family Front View Port AC PowerFibre ArrayDescription Hardware Ordering InformationVA7100 Hardware Ordering Information VA7100 Field RK SKUA6183AE VA7100 Factory RackDisks Deskside cabinet for HP StorageWorks VA7100Part Number Description VA7100 Rail KitsVA7110 Hardware Ordering Information VA7110 Field RK SKUVA7110 Rail Kits VA7410 Controller Enclosure Hardware Ordering Information VA7410 Enterprise Factory RackProduct Option Description Number VA7410 Rail KitsVA7410 Enterprise Modules DS2405 Disk System Accessories Disk System Enclosure DS2405 Hardware Ordering InformationPart Number Description Height Units Support Options OverviewVA7000 Family Racking and Rail Kit Options 9122 Rack Meters 22U 9136 36U 9142 42USupport SD, 24×7 VA Hardware Description 3-year Installation Year Support SDIndirect Commercial Support Packs 24×7 Start-Up NumbersDescription of Services Offered Hardware and Software-Additional Recommended ServicesCode Description Early Warning Switch BatteryDisk Drives Loading Rules Drive size GB 36 GB 73 GB Hot Spares Number of drivesEstimated Usable Capacity for AutoRAID-VA7100 Drive size GB 36 GB 73 GB 146 GB Hot Spares Estimated Usable Capacity for RAID 1+0-VA7110Estimated Usable Capacity for AutoRAID-VA7110 Capacity in GBMidplane Redundant Power Supply and Fan ModulesGbic VA7100 only LED Status IndicationsSupported Operating Systems Array LogsHBA Support Supported Hardware DevicesHub Support Supported Fibre Channel Cables Switch SupportSupported Disk Drives Part Number Description All Operating SystemsConfiguration Front End and Back End CablingLong-Distance Configurations Not supported on MPE/iX SAN DefinitionsMPE ControllerSwitch SAN Configurations Dual HBA Dual controllers Management Station requiredSwitch Windows ServerFibre channel short-wave optical only LAN connection Cable/Connection LegendBuilding Native Fibre ChannelSoftware Products Software Products Reference ChartSoftware Product Descriptions Software Product Source DescriptionOperating System HP StorageWorks Command View SDM SoftwareHP StorageWorks Command View SDM Software Compatibility Memory Video Disk Space2Component HP StorageWorks Command View SDM Frequently Asked QuestionsDisks Fans HP StorageWorks Integrations Pack HP StorageWorks Integrations Pack FeaturesHP StorageWorks Integrations Pack Compatibility HP StorageWorks Business Copy VA Software Compatibility HP StorageWorks Business Copy VA FeaturesHP StorageWorks Business Copy VA Memory Disk SpaceHP StorageWorks Secure Manager VA Features HP StorageWorks Business Copy VA Frequently Asked QuestionsHP StorageWorks Secure Manager VA See above Solaris 2.6, 7.0, 8.0 HP StorageWorks Secure Manager VA Software CompatibilityHP StorageWorks Auto Path See above Novell Netware 5.0,5.1HP StorageWorks Auto Path Operating Systems Compatibility HP StorageWorks Auto Path FeaturesHP StorageWorks Auto Path Frequently Asked Questions HP StorageWorks Auto Path Software CompatibilityVA7000 Family Software Ordering Information HP StorageWorks Fast Recovery Solutions FeaturesOption Description One software support warranty option required RequiredProduct Number Option Description Enablement One 1 software support warranty option requiredSoftware support warranty option required Option requiredCapacity unlimited Warranty option requiredUnlimited Glossary Abbreviation Description