HP VA7410 manual Estimated Usable Capacity for RAID 1+0-VA7110, Capacity in GB

Page 25

Chapter 4

Peripherals and Accessories

Estimated Usable Capacity for RAID 1+0—VA7110

This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7110 with 36-, 73-, and 146-GB drives with or without the use of hot spare drives.

Capacity Table 1 GB

Drive size (GB)

36 GB

36 GB

73 GB

73 GB

146 GB

146 GB

Hot Spares

2

0

2

0

2

0

Number of drives

Maximum usable

Maximum usable

Maximum usable

Maximum usable

Maximum usable

Maximum usable

 

capacity in GB

capacity in GB

capacity in GB

capacity in GB

capacity in GB

capacity in GB

4

29

58

65

130

136

273

8

97

133

205

277

420

563

12

205

205

420

420

850

850

16

277

277

563

563

1137

1137

20

348

348

707

707

1423

1423

24

420

420

850

850

1710

1710

28

492

492

993

993

1997

1997

32

563

563

1137

1137

2284

2284

36

635

635

1280

1280

2570

2570

40

707

707

1423

1423

2857

2857

44

778

778

1567

1567

3144

3144

45

796

796

1603

1603

3215

3215

Estimated Usable Capacity for AutoRAID—VA7110

This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7110 with 36-, 73-, and 146-GB drives and with or without the use of hot spare drives.

Capacity Table 1 GB

Drive size (GB)

36 GB

36 GB

73 GB

73 GB

146 GB

146 GB

Hot Spares

2

0

2

0

2

0

Number of drives

Maximum usable

Maximum usable

Maximum usable

Maximum usable

Maximum usable

Maximum usable

 

capacity in GB

capacity in GB

capacity in GB

capacity in GB

capacity in GB

capacity in GB

4

29

58

65

130

136

273

8

126

186

265

391

542

800

12

252

317

522

653

1036

1325

16

383

448

784

915

1587

1849

20

514

579

1046

1176

2110

2371

24

644

710

1307

1437

2632

2893

28

775

840

1568

1698

3154

3415

32

905

970

1829

1959

3676

3937

36

1036

1101

2089

2220

4197

4458

40

1166

1231

2350

2481

4719

4980

44

1296

1362

2611

2741

5240

5501

45

1329

1394

2676

2807

5371

5631

HP e3000 Business Servers Configuration Guide – Effective 1/04

4-115

Information Subject to Change

 

Image 25
Contents Overview IntroductionVA7110 Overview VA7410 Overview Http//partner.americas.hp.com New Firmware Revision Code Designation for VA7410 Product FeaturesImportant VA7410/DS2405 Notes VA7110 Disk Enclosure Specifications DS2405 Specifications WarrantyInstant Support Enterprise Edition Support Isee VA7110 and VA7410 Controller Enclosure Specifications Temperature To 35 C 41 to 95 F DS2405 Disk Enclosure Specifications10% to 90% @ 28 C dry bulb Shock 11 ms half sine Vibration Rms, 5- to 500-Hz random1.1 HP StorageWorks Virtual Array 7000 Family Front View Fibre AC PowerPort ArrayVA7100 Hardware Ordering Information Hardware Ordering InformationDescription VA7100 Field RK SKUDisks VA7100 Factory RackA6183AE Deskside cabinet for HP StorageWorks VA7100VA7110 Hardware Ordering Information VA7100 Rail KitsPart Number Description VA7110 Field RK SKUVA7110 Rail Kits VA7410 Enterprise Factory Rack VA7410 Controller Enclosure Hardware Ordering InformationProduct Option Description Number VA7410 Rail KitsVA7410 Enterprise Modules Disk System Enclosure DS2405 Hardware Ordering Information DS2405 Disk System AccessoriesVA7000 Family Racking and Rail Kit Options Support Options OverviewPart Number Description Height Units 9122 Rack Meters 22U 9136 36U 9142 42UIndirect Commercial Support Packs VA Hardware Description 3-year Installation Year Support SDSupport SD, 24×7 24×7 Start-Up NumbersDescription of Services Offered Hardware and Software-Additional Recommended ServicesCode Description Early Warning Switch BatteryDisk Drives Drive size GB 36 GB 73 GB Hot Spares Number of drives Loading RulesEstimated Usable Capacity for AutoRAID-VA7100 Estimated Usable Capacity for AutoRAID-VA7110 Estimated Usable Capacity for RAID 1+0-VA7110Drive size GB 36 GB 73 GB 146 GB Hot Spares Capacity in GBGbic VA7100 only Redundant Power Supply and Fan ModulesMidplane LED Status IndicationsArray Logs Supported Operating SystemsHBA Support Supported Hardware DevicesHub Support Supported Disk Drives Switch SupportSupported Fibre Channel Cables Part Number Description All Operating SystemsFront End and Back End Cabling ConfigurationSAN Definitions Long-Distance Configurations Not supported on MPE/iXController MPESwitch Dual HBA Dual controllers Management Station required SAN ConfigurationsWindows Server SwitchBuilding Cable/Connection LegendFibre channel short-wave optical only LAN connection Native Fibre ChannelSoftware Product Descriptions Software Products Reference ChartSoftware Products Software Product Source DescriptionHP StorageWorks Command View SDM Software Compatibility HP StorageWorks Command View SDM SoftwareOperating System Memory Video Disk Space2Component HP StorageWorks Command View SDM Frequently Asked QuestionsDisks Fans HP StorageWorks Integrations Pack HP StorageWorks Integrations Pack FeaturesHP StorageWorks Integrations Pack Compatibility HP StorageWorks Business Copy VA HP StorageWorks Business Copy VA FeaturesHP StorageWorks Business Copy VA Software Compatibility Memory Disk SpaceHP StorageWorks Secure Manager VA Features HP StorageWorks Business Copy VA Frequently Asked QuestionsHP StorageWorks Secure Manager VA HP StorageWorks Auto Path HP StorageWorks Secure Manager VA Software CompatibilitySee above Solaris 2.6, 7.0, 8.0 See above Novell Netware 5.0,5.1HP StorageWorks Auto Path Frequently Asked Questions HP StorageWorks Auto Path FeaturesHP StorageWorks Auto Path Operating Systems Compatibility HP StorageWorks Auto Path Software CompatibilityVA7000 Family Software Ordering Information HP StorageWorks Fast Recovery Solutions FeaturesOption Description Required One software support warranty option requiredSoftware support warranty option required Enablement One 1 software support warranty option requiredProduct Number Option Description Option requiredCapacity unlimited Warranty option requiredUnlimited Abbreviation Description Glossary