HP Accessory 651176-002 manual Installation, Precautions, Preparing to install the hardware

Page 13

Installation

Precautions

Save these instructions. This document contains important safety instructions that should be followed during installation, operation, and maintenance of the UPS and batteries.

WARNING: A risk of personal injury from electric shock and hazardous energy levels exists. The installation of options and routine maintenance and service of this product must be performed by individuals who are knowledgeable about the procedures, precautions, and hazards associated with AC power products.

This symbol indicates that the UPS exceeds the recommended weight for one individual to handle safely.

37 kg WARNING: To reduce the risk of personal injury or damage to the equipment, observe

82 lb local occupational health and safety requirements and guidelines for manual material handling.

This symbol indicates that the ERM exceeds the recommended weight for one individual to handle safely.

45 kg WARNING: To reduce the risk of personal injury or damage to the equipment, observe

100 lb local occupational health and safety requirements and guidelines for manual material handling.

WARNING: To prevent personal injury from earth conductor leakage current:

Do not operate the UPS while disconnected from the utility power source.

Disconnect load devices before disconnecting the UPS from the utility power source.

Preparing to install the hardware

Before installing the hardware:

1.Be sure the necessary tools and materials (on page 13) are available.

2.Select an installation site ("Selecting a site" on page 14).

3.Prepare the equipment ("Readying the equipment" on page 14) for installation in the rack.

Tools and materials

The following tools are required for installation:

Phillips screwdriver

10-mm hex-nut driver

The following items are supplied with the rack:

Screws

Installation 13

Image 13
Contents HP R/T3000 G2 UPS User Guide Page Contents Power management Spares Acronyms and abbreviations Documentation feedback Index UPS R/T3000 G2 overview Component identificationUPS front panel UPS front panel controls UPS front panel LED indicatorsT3000 NA and R/T3000j JPN rear panel HP UPS R/T3000 modelsT3000h NA and R/T3000h JPN rear panel Repo port T3000 INT rear panelERM rear panel Precautions InstallationPreparing to install the hardware Tools and materialsSelecting a site Installing the mounting railsReadying the equipment Installation Installation Installing the UPS in a rack Connecting the battery leads Installation Attaching the UPS front bezel Connecting the host computer Connecting the serial communications port Connecting the Repo portInstallation Connecting the ground bonding cable Connecting devices to the UPS Connecting the UPS to utility powerInstallation Starting power to the load Installing the ERM in a rackConnecting the battery leads Attaching the ERM front bezel Connecting the ERM to the UPS Installation Installing the optional UPS Network Module Connecting the UPS Network Module Installing the UPS as a towerConnecting the battery leads Rotating the logo badge Continuing the installation Installing the ERM as a tower Installation Continuing the ERM installation Installing the extension bars if included Connecting and securing the power cords Operate mode Standby modeUPS operations Modes of operationBattery mode Configure modeAuto-Bypass mode Operating the UPS front panel controlsConfiguring the UPS Initiating a self-test Powering down the UPS Silencing an audible alarmVerifying the Repo port connection Maintenance Battery care and storage guidelines Important battery safety informationDetermining when to replace batteries Obtaining new batteries UPS battery replacement procedureTesting the new battery module Replacing the ERM Replacing the UPSReplacing the UPS option card Updating the UPS firmware Configuring a USB to serial converterReassigning the USB COM ports Maintenance Power Protector software Power managementPower management LED troubleshooting TroubleshootingUPS is in Auto-Bypass mode General alarm condition UPS is in Converter Off modeUPS is on battery Battery conditionBypass is out of range Input voltage is out of rangeInternal UPS fault condition Overtemperature conditionSite wiring condition Repo conditionLow battery shutdowns Checksum failure errorUPS does not provide the expected backup time UPS frequently switches between utility and battery powerUPS physical specifications SpecificationsERM physical specifications UPS input specificationsPower protection specifications Battery specificationsOutput tolerance specifications Output feature specificationsLow-voltage UPS battery runtimes High-voltage UPS battery runtimesEnvironmental specifications Repo port specificationsSpares UPS spare parts listOrdering spares Hardware options ERM spare parts listBefore you contact HP Support and other resourcesHP contact information Limited warranty Warranty information$250,000 Computer Load Protection Guarantee Pre-Failure Battery WarrantyRecommended duration of use Regulatory compliance identification numbers Regulatory compliance noticesFederal Communications Commission notice Cables ModificationsCanadian notice Avis Canadien European Union regulatory notice Japanese notice Bsmi notice Korean notice Taiwan battery recycling notice Battery replacement noticeChinese notice Power cord statement for Japan Preventing electrostatic discharge Electrostatic dischargeGrounding methods to prevent electrostatic discharge Acronyms and abbreviations Documentation feedback Index On button, location UPS is on battery