Electrostatic discharge

Preventing electrostatic discharge

To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.

To prevent electrostatic damage:

Avoid hand contact by transporting and storing products in static-safe containers.

Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.

Place parts on a grounded surface before removing them from their containers.

Avoid touching pins, leads, or circuitry.

Always be properly grounded when touching a static-sensitive component or assembly.

Grounding methods to prevent electrostatic discharge

Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts:

Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.

Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.

Use conductive field service tools.

Use a portable field service kit with a folding static-dissipating work mat.

If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part.

For more information on static electricity or assistance with product installation, contact an authorized reseller.

Electrostatic discharge 75

Image 75
Contents HP R/T3000 G2 UPS User Guide Page Contents Power management Spares Acronyms and abbreviations Documentation feedback Index Component identification UPS R/T3000 G2 overviewUPS front panel UPS front panel controls UPS front panel LED indicatorsT3000 NA and R/T3000j JPN rear panel HP UPS R/T3000 modelsT3000h NA and R/T3000h JPN rear panel Repo port T3000 INT rear panelERM rear panel Tools and materials InstallationPrecautions Preparing to install the hardwareInstalling the mounting rails Selecting a siteReadying the equipment Installation Installation Installing the UPS in a rack Connecting the battery leads Installation Attaching the UPS front bezel Connecting the host computer Connecting the serial communications port Connecting the Repo portInstallation Connecting the ground bonding cable Connecting devices to the UPS Connecting the UPS to utility powerInstallation Starting power to the load Installing the ERM in a rackConnecting the battery leads Attaching the ERM front bezel Connecting the ERM to the UPS Installation Installing the optional UPS Network Module Connecting the UPS Network Module Installing the UPS as a towerConnecting the battery leads Rotating the logo badge Continuing the installation Installing the ERM as a tower Installation Continuing the ERM installation Installing the extension bars if included Connecting and securing the power cords Modes of operation Standby modeOperate mode UPS operationsOperating the UPS front panel controls Configure modeBattery mode Auto-Bypass modeConfiguring the UPS Initiating a self-test Silencing an audible alarm Powering down the UPSVerifying the Repo port connection Maintenance Important battery safety information Battery care and storage guidelinesDetermining when to replace batteries Obtaining new batteries UPS battery replacement procedureTesting the new battery module Replacing the UPS Replacing the ERMReplacing the UPS option card Updating the UPS firmware Configuring a USB to serial converterReassigning the USB COM ports Maintenance Power Protector software Power managementPower management LED troubleshooting TroubleshootingUPS is in Auto-Bypass mode General alarm condition UPS is in Converter Off modeInput voltage is out of range Battery conditionUPS is on battery Bypass is out of rangeRepo condition Overtemperature conditionInternal UPS fault condition Site wiring conditionUPS frequently switches between utility and battery power Checksum failure errorLow battery shutdowns UPS does not provide the expected backup timeUPS input specifications SpecificationsUPS physical specifications ERM physical specificationsOutput feature specifications Battery specificationsPower protection specifications Output tolerance specificationsRepo port specifications High-voltage UPS battery runtimesLow-voltage UPS battery runtimes Environmental specificationsUPS spare parts list SparesOrdering spares Hardware options ERM spare parts listSupport and other resources Before you contact HPHP contact information Pre-Failure Battery Warranty Warranty informationLimited warranty $250,000 Computer Load Protection GuaranteeRecommended duration of use Regulatory compliance notices Regulatory compliance identification numbersFederal Communications Commission notice Modifications CablesCanadian notice Avis Canadien European Union regulatory notice Japanese notice Bsmi notice Korean notice Battery replacement notice Taiwan battery recycling noticeChinese notice Power cord statement for Japan Electrostatic discharge Preventing electrostatic dischargeGrounding methods to prevent electrostatic discharge Acronyms and abbreviations Documentation feedback Index On button, location UPS is on battery