COOLING AND CONTINUOUS FAN SPEEDS

All installations and services must be performed by qualified service personnel.

COOLING AND CONTINUOUS FAN SPEEDS

CDX1-75 & CHX1-75

Dip

Continuous

 

switch

fan

 

setting

CFM

Cooling CFM

1-OFF

 

 

2-OFF

 

 

3-ON

 

 

4-OFF

500

1150

1-OFF

 

 

2-OFF

 

 

3-OFF

 

 

4-OFF

500

1000

1-OFF

 

 

2-OFF

 

 

3-OFF

 

 

4-ON

500

850

1-ON

 

 

2-OFF

 

 

3-ON

 

 

4-OFF

400

920

1-ON

 

 

2-OFF

 

 

3-OFF

 

 

4-OFF

400

800

1-ON

 

 

2-OFF

 

 

3-OFF

 

 

4-ON

400

680

1-OFF

 

 

2-ON

 

 

3-ON

 

 

4-OFF

600

1380

1-OFF

 

 

2-ON

 

 

3-OFF

 

 

4-OFF

600

1200

1-OFF

 

 

2-ON

 

 

3-OFF

 

 

4-ON

600

1020

1-ON

 

 

2-ON

 

 

3-ON

 

 

4-OFF

700

1600

1-ON

 

 

2-ON

 

 

3-OFF

 

 

4-OFF

700

1400

1-ON

 

 

2-ON

 

 

3-OFF

 

 

4-ON

700

1190

CDX1-100 & CHX1-100

Dip

Continuous

 

switch

fan

 

setting

CFM

Cooling CFM

1-OFF

 

 

2-OFF

 

 

3-ON

 

 

4-OFF

600

1380

1-OFF

 

 

2-OFF

 

 

3-OFF

 

 

4-OFF

600

1200

1-OFF

 

 

2-OFF

 

 

3-OFF

 

 

4-ON

600

1020

1-ON

 

 

2-OFF

 

 

3-ON

 

 

4-OFF

500

1150

1-ON

 

 

2-OFF

 

 

3-OFF

 

 

4-OFF

500

1000

1-ON

 

 

2-OFF

 

 

3-OFF

 

 

4-ON

500

850

1-OFF

 

 

2-ON

 

 

3-ON

 

 

4-OFF

700

1610

1-OFF

 

 

2-ON

 

 

3-OFF

 

 

4-OFF

700

1400

1-OFF

 

 

2-ON

 

 

3-OFF

 

 

4-ON

700

1190

1-ON

 

 

2-ON

 

 

3-ON

 

 

4-OFF

800

1700

1-ON

 

 

2-ON

 

 

3-OFF

 

 

4-OFF

800

1600

1-ON

 

 

2-ON

 

 

3-OFF

 

 

4-ON

800

1360

CDX1-125 & CHX1-125

Dip

Continuous

 

switch

fan

 

setting

CFM

Cooling CFM

1-OFF

 

 

2-OFF

 

 

3-ON

 

 

4-OFF

700

1610

1-OFF

 

 

2-OFF

 

 

3-OFF

 

 

4-OFF

700

1400

1-OFF

 

 

2-OFF

 

 

3-OFF

 

 

4-ON

700

1190

1-ON

 

 

2-OFF

 

 

3-ON

 

 

4-OFF

600

1380

1-ON

 

 

2-OFF

 

 

3-OFF

 

 

4-OFF

600

1200

1-ON

 

 

2-OFF

 

 

3-OFF

 

 

4-ON

600

1020

1-OFF

 

 

2-ON

 

 

3-ON

 

 

4-OFF

800

1840

1-OFF

 

 

2-ON

 

 

3-OFF

 

 

4-OFF

800

1600

1-OFF

 

 

2-ON

 

 

3-OFF

 

 

4-ON

800

1360

1-ON

 

 

2-ON

 

 

3-ON

 

 

4-OFF

1000

2300

1-ON

 

 

2-ON

 

 

3-OFF

 

 

4-OFF

1000

2000

1-ON

 

 

2-ON

 

 

3-OFF

 

 

4-ON

1000

1700

Manual backgroundManual background =FACTORY SHIPPED SETTINGS

5

Image 7
Contents FOR USE WITH MODELS CHX1-75N CDX1-75N MG-1018CHX1-100N CDX1-100N CHX1-125N CDX1-125N SECTION INDEXBEGINNING PAGE CHX1-100 POWER CHOKESMODEL NO CHX1-75CDX1-125 CDX1 SERIESCDX1-75 CDX1-100Figure 1 BLOWER WIRING II.BLOWER INFORMATION A. WIRINGB. CFM TABLES COOLING AND CONTINUOUS FAN SPEEDS Motor rocks slightly when starting III.ECM TROUBLE SHOOTINGSYMPTOM CAUSE/PROCEDUREMoisture Check Evidence of MoisturePerform Moisture Check DON’TFigure 2 ECM PIN CONNECTORS B. TROUBLESHOOTING CHARTS