HP 5697-7483 manual Setup, Shipping carton contents

Page 19

2 Setup

This chapter provides the following information:

Shipping carton contents, page 19

Installation and safety considerations, page 20

Install the 8Gb SAN Switch, page 20

Set the IP address, page 23

Configure the 4Gb SAN Switch, page 25

Shipping carton contents

Figure 3 and Table 8 identify the 8Gb SAN Switch shipping carton contents:

Brocade 8Gb SAN Switch for HP BladeSystem c-Class installation instructions

SFP dust covers (must be inserted in ports where Small Form-factor Pluggable (SFP) optical transceivers are not installed)

Four Short Wavelengh (SWL) 8Gb SFPs, (in styrofoam packing)

One Brocade 8Gb SAN Switch; models include:

Brocade 8/12 SAN Switch for HP BladeSystem c-Class with twelve active ports

Brocade 8/24 SAN Switch for HP BladeSystem c-Class with sixteen internal and eight external active ports

Brocade 8/24 SAN Switch Power Pack+ for HP BladeSystem c-Class with sixteen internal and eight external active ports

2

3

1

scale: 3/8" = 1"

26480a

Figure 3 Carton contents

Table 5 identifies 8Gb SAN Switch components.

Table 8 Brocade 8Gb SAN Switch components

Item

1

2

3

Description

Brocade 8Gb SAN Switch, ships with four Short Wavelengh (SWL) 8Gb SFPs, (in styrofoam packing)

Dust covers for empty SFP ports

Brocade 8Gb SAN Switch for HP BladeSystem c-Class installation instructions

Brocade 8Gb SAN Switch for HP BladeSystem c-Class

19

Image 19
Contents Brocade 8Gb SAN Switch for HP BladeSystem c-Class Page Contents Electrostatic discharge Managing the 8Gb SAN SwitchRegulatory compliance and safety SAN Switch technical specificationsIndex Figures Tables Page HP BladeSystem c-Class related documentation SAN Switch related documentationAbout this guide Intended audienceConvention Element Document conventions and symbolsHP contact information Document conventionsTIP Subscription serviceOther HP websites Documentation feedbackAbout this guide Overview 8Gb SAN Switch featuresItem number Description Component identification8Gb SAN Switch licensing 8Gb SAN Switch redundancyInternal ports summary Option Part number ISL trunking groups Supported optional software Optional software kitsDistance OM2 Cable OM3 Cable Supported SFP transceiver optionsThrough lists the only supported SFPs Optional Long Wave 4Gb SFPsOverview Shipping carton contents SetupElectrical considerations Installation and safety considerationsInstall the 8Gb SAN Switch Installing multiple switchesScale 2/3 = Check LEDs OA power verificationUsing Enclosure Bay IP Addressing Ebipa Set the switch Ethernet IP addressSetting the IP address manually Using external DhcpConnect to the Command Line Interface Configure the 8Gb SAN SwitchItems required for configuration Verifying installed licenses Setting the date and timeModifying the FC domain ID optional Disabling and enabling a switchEnter a unique domain ID. For example Dpod commands Using Dynamic Ports On Demand DpodDisabling and enabling a port Verifying the configuration Example for Brocade 8/12 SAN SwitchBacking up the configuration Enter fabricshow to get general information about the fabricManagement tool Out-of-band support In-band support Managing the 8Gb SAN SwitchManagement features 8Gb SAN Switch management featuresReplacing an SFP transceiver Maintaining the 8Gb SAN SwitchInstalling dust covers in empty ports Connecting with a management stationDiagnostic tests Powering on and offOrient the SFP with the appropriate port. See and Table LED patterns LED indicatorsItem Number Description LED indicators Interpreting LED activityPort link status LED patterns Module status LED patternsPort link status LED patterns Module Status LED patterns during normal operationBoot Post and boot specificationsInterpreting Post results About the reset button Firmware updateRebooting the switch Replacing a faulty 8Gb SAN SwitchBrocade 8Gb SAN Switch for HP BladeSystem c-Class Managing the 8Gb SAN Switch Laser device compliance Regulatory compliance and safetyRegulatory compliance Regulatory compliance identification numbersCanadian notice avis Canadien International notices and statementsEuropean union regulatory notice Bsmi notice Japanese notice Korean notice SafetyBattery replacement notice Taiwan battery recycling noticeJapanese power cord statement Power cordsRegulatory compliance and safety This appendix provides the following information How to prevent electrostatic dischargeElectrostatic discharge Grounding methodsElectrostatic discharge Specification Description SAN Switch technical specificationsGeneral specifications General specificationsEnvironmental requirements Weight and physical dimensions8Gb SAN Switch physical dimensions Environmental requirementsSupported HBAs Supported SFPsSAN Switch technical specifications Glossary Edtov FCS switch Fibre Channel fill wordDLS Domain IDFspf FlogiFRU FSPLWL LIPLmtov LpsmRrtov PlogiRatov RAIDSnmp RscnSAN SdramFabric has a distinct WWN WWNGlossary LED IndexISL Trunking groupsTransceiver, 13, 14, 25, 33, 35