Reset
0
23
22 21
20
19
18
17
!
2
B | ROCADE |
Switch |
bSAN
1
26479a
Figure 7 Installing an SFP
Table 13 SFP components
Item
1
2
Description
bail
SFP
3.Insert the SFP into the port until you hear a click.
4.Close the bail.
Diagnostic tests
In addition to POST, Fabric OS includes diagnostic tests to help troubleshoot the hardware and the firmware including tests of internal connections and circuitry, fixed media, and the transceivers and cables in use.
Initiate diagnostic tests with the command line, using a Telnet session or a terminal setup with a serial connection to the switch. Some tests require the ports to be connected by external cables to allow diagnostics to verify the serializer/deserializer interface, transceiver, and cable. For information on available diagnostic tests, enter diagHelp.
All diagnostic tests are run at link speeds of 1 Gbps, 2 Gbps, 4 Gbps, and 8 Gbps.
CAUTION:
Diagnostic tests can temporarily lock the transmit and receive speed of the links during diagnostic testing.
For information about specific diagnostic tests, refer to the latest version of the HP StorageWorks Fabric OS administrator guide, or enter help followed by the name of the diagnostic test.
Powering on and off
8Gb SAN Switch power is provided by the enclosure. The 8Gb SAN Switch runs POST by default each time power to the enclosure is turned on. The POST process can last as long as three minutes.
To remove power from the switch, remove the 8Gb SAN Switch from the enclosure interconnect bay.
Brocade 8Gb SAN Switch for HP BladeSystem | 33 |