HP 5697-7483 manual Powering on and off, Diagnostic tests

Page 33

2.Orient the SFP with the appropriate port. See Figure 7 and Table 13.

scale: 3/8" = 1"

Reset

0

23

22 21

20

19

18

17

!

2

B

ROCADE

Switch

bSAN

1

26479a

Figure 7 Installing an SFP

Table 13 SFP components

Item

1

2

Description

bail

SFP

3.Insert the SFP into the port until you hear a click.

4.Close the bail.

Diagnostic tests

In addition to POST, Fabric OS includes diagnostic tests to help troubleshoot the hardware and the firmware including tests of internal connections and circuitry, fixed media, and the transceivers and cables in use.

Initiate diagnostic tests with the command line, using a Telnet session or a terminal setup with a serial connection to the switch. Some tests require the ports to be connected by external cables to allow diagnostics to verify the serializer/deserializer interface, transceiver, and cable. For information on available diagnostic tests, enter diagHelp.

All diagnostic tests are run at link speeds of 1 Gbps, 2 Gbps, 4 Gbps, and 8 Gbps.

CAUTION:

Diagnostic tests can temporarily lock the transmit and receive speed of the links during diagnostic testing.

For information about specific diagnostic tests, refer to the latest version of the HP StorageWorks Fabric OS administrator guide, or enter help followed by the name of the diagnostic test.

Powering on and off

8Gb SAN Switch power is provided by the enclosure. The 8Gb SAN Switch runs POST by default each time power to the enclosure is turned on. The POST process can last as long as three minutes.

To remove power from the switch, remove the 8Gb SAN Switch from the enclosure interconnect bay.

Brocade 8Gb SAN Switch for HP BladeSystem c-Class

33

Image 33
Contents Brocade 8Gb SAN Switch for HP BladeSystem c-Class Page Contents Regulatory compliance and safety Managing the 8Gb SAN SwitchSAN Switch technical specifications Electrostatic dischargeIndex Figures Tables Page About this guide SAN Switch related documentationIntended audience HP BladeSystem c-Class related documentationHP contact information Document conventions and symbolsDocument conventions Convention ElementOther HP websites Subscription serviceDocumentation feedback TIPAbout this guide Overview 8Gb SAN Switch featuresItem number Description Component identification8Gb SAN Switch redundancy 8Gb SAN Switch licensingInternal ports summary Supported optional software ISL trunking groupsOptional software kits Option Part numberThrough lists the only supported SFPs Supported SFP transceiver optionsOptional Long Wave 4Gb SFPs Distance OM2 Cable OM3 CableOverview Shipping carton contents SetupInstall the 8Gb SAN Switch Installation and safety considerationsInstalling multiple switches Electrical considerationsScale 2/3 = Check LEDs OA power verificationUsing Enclosure Bay IP Addressing Ebipa Set the switch Ethernet IP addressSetting the IP address manually Using external DhcpConfigure the 8Gb SAN Switch Connect to the Command Line InterfaceItems required for configuration Verifying installed licenses Setting the date and timeDisabling and enabling a switch Modifying the FC domain ID optionalEnter a unique domain ID. For example Using Dynamic Ports On Demand Dpod Dpod commandsDisabling and enabling a port Verifying the configuration Example for Brocade 8/12 SAN Switch Backing up the configuration Enter fabricshow to get general information about the fabricManagement features Managing the 8Gb SAN Switch8Gb SAN Switch management features Management tool Out-of-band support In-band supportInstalling dust covers in empty ports Maintaining the 8Gb SAN SwitchConnecting with a management station Replacing an SFP transceiverPowering on and off Diagnostic testsOrient the SFP with the appropriate port. See and Table Item Number Description LED indicators LED indicatorsInterpreting LED activity LED patternsPort link status LED patterns Module status LED patternsModule Status LED patterns during normal operation Port link status LED patternsPost and boot specifications BootInterpreting Post results About the reset button Firmware updateRebooting the switch Replacing a faulty 8Gb SAN SwitchBrocade 8Gb SAN Switch for HP BladeSystem c-Class Managing the 8Gb SAN Switch Regulatory compliance Regulatory compliance and safetyRegulatory compliance identification numbers Laser device complianceCanadian notice avis Canadien International notices and statementsEuropean union regulatory notice Bsmi notice Japanese notice Battery replacement notice SafetyTaiwan battery recycling notice Korean noticeJapanese power cord statement Power cordsRegulatory compliance and safety Electrostatic discharge How to prevent electrostatic dischargeGrounding methods This appendix provides the following informationElectrostatic discharge General specifications SAN Switch technical specificationsGeneral specifications Specification Description8Gb SAN Switch physical dimensions Weight and physical dimensionsEnvironmental requirements Environmental requirementsSupported HBAs Supported SFPsSAN Switch technical specifications Glossary DLS FCS switch Fibre Channel fill wordDomain ID EdtovFRU FlogiFSP FspfLmtov LIPLpsm LWLRatov PlogiRAID RrtovSAN RscnSdram SnmpFabric has a distinct WWN WWNGlossary ISL IndexTrunking groups LEDTransceiver, 13, 14, 25, 33, 35