Thermo Products GMD1-60N, GDM1-80N service manual Alcove Installation

Page 15

All installations and services must be performed by qualified service personnel.

CAUTION: A permanent opening with a minimum of 50 square inches of unobstructed infiltration (free area) for ventilation and combustion air must be provided to the interior of the structure. Additional make-up air may need to be supplied to the interior of the structure to compensate for exhaust fans, appliances, or vents, which consume air from the interior of the structure.

Refer to the assembly installation instructions included with OM1COT-BASE cottage base for additional information.

3.Coil Cabinet: CE111S / CE211T

The CE111S / CE211T coil cabinet (figure 1C) is for applications requiring air conditioning. The coil cabinet is designed to have the combustion air brought in from the bottom thru a flexible hose, supplied with the cabinet. Refer to section G Combustion air of this manual for further instructions on the combustion air termination and connections. For additional information refer instructions provided with the coil cabinet.

E. ALCOVE INSTALLATION

In this application, a minimum of 18 inches of clearance must be provided to the front of the unit. Refer to Figure 4.

Alcove installations must use the No. 70 mobile home base.

Note – access to diagnostic view port.

Refer to section G. COMBUSTION AIR for additional combustion air requirements.

Figure 4

14

Image 15
Contents GAS-FIRED Furnace Safety Section Page What to do if YOU Smell GAS All installations Table of Contents Section Beginning Page Closet Alcove GMD1-60 GMD1-80 III. Furnace Specifications ModelGMD1-60 Blower DataIV. Installation Roof Jack Standard ChimneyFurnace Location Page Base Installation Page Alcove Installation Closet Installation  Warning Hazard Combustion AIR Page GAS Piping Electrical Wiring AWG Adjustment of Heat Input Rate Initial Start UPOperating Instructions Supply Pressure Manifold Pressure NAT Burner Adjustment Setting Temperature Rise Furnace Checkout Procedure Installers Instructions to User VI. Starting the Unit Refer to the Troubleshooting Section of this Manual Page Power must be disconnected before servicing Diagnostic FeaturesTurn Tstat Setting Above Room Temp Yes After GAS Valve OPENS, do the Burners IGNITE? Check ALL VIII. Dealer Maintenance ElectricalBurners Inspecting the Venting System Inducer Blower AssemblyExtended Shutdown GASKETS/SEALING MaterialsHeat Exchanger House AIR BlowerIX. User Information Section Inspection Areas Component LocationsFilter Location and Cleaning Appendix a Replacement Parts Page Appendix B Wiring Diagram

GMD1-60N, GDM1-80N specifications

Thermo Products has established itself as a leader in the manufacturing of high-performance heating solutions. Among their notable offerings are the GDM1-80N and GMD1-60N units, which have garnered attention for their innovative features and reliable performance.

The GDM1-80N is designed for applications that require robust heating capabilities. This model boasts an impressive output capacity, making it suitable for industrial and commercial settings. One of its key features is the advanced temperature control system that ensures consistent heating across various environments. This system utilizes precision sensors that monitor temperature in real-time, allowing for adjustments to maintain the desired levels effectively.

Another notable characteristic of the GDM1-80N is its energy efficiency. It is engineered with state-of-the-art technology that minimizes energy consumption while maximizing heat output. This is particularly beneficial for businesses looking to reduce operational costs while still maintaining high-performance heating.

In contrast, the GMD1-60N is tailored for slightly less demanding applications but still delivers exceptional performance. With a compact design, it is ideal for spaces where floor space is limited without compromising on heating efficiency. The GMD1-60N features a user-friendly control interface, allowing operators to easily set and monitor temperatures.

Both models incorporate durable construction materials, ensuring longevity and reliability in various working conditions. The robust design means they can withstand the rigors of industrial use while providing consistent performance over time. Additionally, they are equipped with safety features, including overheat protection and user-accessible maintenance points, which enhance their usability and safety.

Thermo Products has integrated smart technology into these units, with options for remote monitoring and management through IoT devices. This capability allows users to track energy usage and system performance, facilitating better decision-making regarding heating needs and maintenance schedules.

In conclusion, the Thermo Products GDM1-80N and GMD1-60N units represent advanced heating solutions that cater to a range of industrial and commercial applications. With their emphasis on energy efficiency, durability, and smart technology, these models stand out as reliable choices for those seeking effective heating solutions in their operations.