Thermo Products GMD1-60N, GDM1-80N service manual

Page 3

All installations and services must be performed by qualified service personnel.

after turning off the gas supply. A final test for gas leakage must be made after purging the gas line.

: DO NOT wet electronic components during the leak test. Wetting electronic components may damage circuitry and cause a hazardous situation. Dry moisture from all leads and terminals if wetting occurs. Wait at least 24 hours for the circuit to fully dry before energizing the system.

: The furnace and its gas valve must be disconnected from the gas supply during pressure testing of the gas supply system at pressures in excess of 1/2 PSIG or 14.0 inches W.G. The furnace can be isolated from the gas supply by closing its manual shut off valve at test pressures equal to or less than 1/2 PSIG or 14.0 inches W.G.

: Copper and brass tubing and fittings (except tin lined) shall not be used if the gas contains more than a trace (0.3 grains per 100 cubic ft.) of hydrogen sulfide gas. Check with your gas supplier.

: If you suspect there is a problem with the furnace, the venting system or any other related problem, immediately contact a qualified service agency. If a service agency is not available, contact your fuel supplier.

: Personal injury, or property damage, could result from major repair or service of this furnace by anyone other than a qualified contractor. Only the routine maintenance described in the user section of this manual should be performed by the user.

: Do not block or obstruct air openings on the furnace or air openings communicating with the area in which the furnace is installed.

: Do not allow the outside air intake to be blocked or obstructed by vegetation, ice, snow or any other materials.

: Do not use this furnace if any part has been underwater. Immediately call a qualified service agency to inspect the furnace and to replace any part of the electrical or control system, which has been underwater.

: Should overheating occur or the gas supply fail to shut off, shut off the manual gas supply valve to the furnace before shutting off the electrical supply.

2

Image 3
Contents GAS-FIRED Furnace Safety Section Page What to do if YOU Smell GAS All installations Table of Contents Section Beginning Page Closet Alcove GMD1-60 GMD1-80 III. Furnace Specifications ModelGMD1-60 Blower DataIV. Installation Roof Jack Standard ChimneyFurnace Location Page Base Installation Page Alcove Installation Closet Installation  Warning Hazard Combustion AIR Page GAS Piping Electrical Wiring AWG Adjustment of Heat Input Rate Initial Start UPOperating Instructions Supply Pressure Manifold Pressure NAT Burner Adjustment Setting Temperature Rise Furnace Checkout Procedure Installers Instructions to User VI. Starting the Unit Refer to the Troubleshooting Section of this Manual Page Power must be disconnected before servicing Diagnostic FeaturesTurn Tstat Setting Above Room Temp Yes After GAS Valve OPENS, do the Burners IGNITE? Check ALL VIII. Dealer Maintenance ElectricalBurners Inspecting the Venting System Inducer Blower AssemblyExtended Shutdown GASKETS/SEALING MaterialsHeat Exchanger House AIR BlowerIX. User Information Section Inspection Areas Component LocationsFilter Location and Cleaning Appendix a Replacement Parts Page Appendix B Wiring Diagram

GMD1-60N, GDM1-80N specifications

Thermo Products has established itself as a leader in the manufacturing of high-performance heating solutions. Among their notable offerings are the GDM1-80N and GMD1-60N units, which have garnered attention for their innovative features and reliable performance.

The GDM1-80N is designed for applications that require robust heating capabilities. This model boasts an impressive output capacity, making it suitable for industrial and commercial settings. One of its key features is the advanced temperature control system that ensures consistent heating across various environments. This system utilizes precision sensors that monitor temperature in real-time, allowing for adjustments to maintain the desired levels effectively.

Another notable characteristic of the GDM1-80N is its energy efficiency. It is engineered with state-of-the-art technology that minimizes energy consumption while maximizing heat output. This is particularly beneficial for businesses looking to reduce operational costs while still maintaining high-performance heating.

In contrast, the GMD1-60N is tailored for slightly less demanding applications but still delivers exceptional performance. With a compact design, it is ideal for spaces where floor space is limited without compromising on heating efficiency. The GMD1-60N features a user-friendly control interface, allowing operators to easily set and monitor temperatures.

Both models incorporate durable construction materials, ensuring longevity and reliability in various working conditions. The robust design means they can withstand the rigors of industrial use while providing consistent performance over time. Additionally, they are equipped with safety features, including overheat protection and user-accessible maintenance points, which enhance their usability and safety.

Thermo Products has integrated smart technology into these units, with options for remote monitoring and management through IoT devices. This capability allows users to track energy usage and system performance, facilitating better decision-making regarding heating needs and maintenance schedules.

In conclusion, the Thermo Products GDM1-80N and GMD1-60N units represent advanced heating solutions that cater to a range of industrial and commercial applications. With their emphasis on energy efficiency, durability, and smart technology, these models stand out as reliable choices for those seeking effective heating solutions in their operations.