N. FURNACE CHECKOUT PROCEDURE

Before any system of gas piping is finally put into service, it shall be carefully tested to assure that it is gas tight as indicated in section IV. H. Gas Piping of this manual.

NOTICE: All controls on the unit should be checked for proper functioning prior to the qualified service personnel leaving the job site. Specifically the following should be checked:

With furnace in normal heating operation, check to make certain blower will start and stop automatically under control of integrated fan control.

1.Check safety limit control as follows:

a.Shut off incoming power.

b.Block return air opening or disconnect blower motor leads.

c.Restore power to furnace.

d.Set thermostat above room temperature calling for heat.

e.When high air temperatures are reached in furnace at limit control setting with blower out of operation, burner should shut off.

f.Shut off electrical power.

IMPORTANT: Remove blockage or reconnect blower motor and restore power.

2.Make certain thermostat will automatically start and stop furnace.

3.Block the flue pipe outlet gradually until the pressure switch functions shutting off the main burners.

4.Block the inlet gradually until pressure switch functions shutting off the main burners.

IMPORTANT: Remove flue or air inlet blockages when done.

25

Image 26
Contents GAS-FIRED Furnace Safety Section Page What to do if YOU Smell GAS All installations Table of Contents Section Beginning Page Closet Alcove III. Furnace Specifications Model GMD1-60 GMD1-80Blower Data GMD1-60Furnace Location IV. Installation Roof JackStandard Chimney Page Base Installation Page Alcove Installation Closet Installation  Warning Hazard Combustion AIR Page GAS Piping Electrical Wiring AWG Operating Instructions Adjustment of Heat Input RateInitial Start UP Supply Pressure Manifold Pressure NAT Burner Adjustment Setting Temperature Rise Furnace Checkout Procedure Installers Instructions to User VI. Starting the Unit Refer to the Troubleshooting Section of this Manual Page Diagnostic Features Power must be disconnected before servicingTurn Tstat Setting Above Room Temp Yes After GAS Valve OPENS, do the Burners IGNITE? Check ALL Burners VIII. Dealer MaintenanceElectrical Inducer Blower Assembly Inspecting the Venting SystemHouse AIR Blower GASKETS/SEALING MaterialsHeat Exchanger Extended ShutdownIX. User Information Section Component Locations Inspection AreasFilter Location and Cleaning Appendix a Replacement Parts Page Appendix B Wiring Diagram

GMD1-60N, GDM1-80N specifications

Thermo Products has established itself as a leader in the manufacturing of high-performance heating solutions. Among their notable offerings are the GDM1-80N and GMD1-60N units, which have garnered attention for their innovative features and reliable performance.

The GDM1-80N is designed for applications that require robust heating capabilities. This model boasts an impressive output capacity, making it suitable for industrial and commercial settings. One of its key features is the advanced temperature control system that ensures consistent heating across various environments. This system utilizes precision sensors that monitor temperature in real-time, allowing for adjustments to maintain the desired levels effectively.

Another notable characteristic of the GDM1-80N is its energy efficiency. It is engineered with state-of-the-art technology that minimizes energy consumption while maximizing heat output. This is particularly beneficial for businesses looking to reduce operational costs while still maintaining high-performance heating.

In contrast, the GMD1-60N is tailored for slightly less demanding applications but still delivers exceptional performance. With a compact design, it is ideal for spaces where floor space is limited without compromising on heating efficiency. The GMD1-60N features a user-friendly control interface, allowing operators to easily set and monitor temperatures.

Both models incorporate durable construction materials, ensuring longevity and reliability in various working conditions. The robust design means they can withstand the rigors of industrial use while providing consistent performance over time. Additionally, they are equipped with safety features, including overheat protection and user-accessible maintenance points, which enhance their usability and safety.

Thermo Products has integrated smart technology into these units, with options for remote monitoring and management through IoT devices. This capability allows users to track energy usage and system performance, facilitating better decision-making regarding heating needs and maintenance schedules.

In conclusion, the Thermo Products GDM1-80N and GMD1-60N units represent advanced heating solutions that cater to a range of industrial and commercial applications. With their emphasis on energy efficiency, durability, and smart technology, these models stand out as reliable choices for those seeking effective heating solutions in their operations.