Thermo Products GDM1-80N, GMD1-60N service manual VI. Starting the Unit

Page 28

All installations and services must be performed by qualified service personnel.

VI. STARTING THE UNIT

A. SEQUENCE OF OPERATIONS

AT ANY TIME THE

GAS VALVE IS

NOT ENERGIZED

START

CONTINUOUS SAFE OPERATION CHECK IF FLAME SIMULATION CONDITION PRESENT OR ROLL-OUT SWITCH OPENS, SYSTEM ENERGIZES INDUCER FAN FOR 15 SECONDS AND CIRCULATOR BLOWER AT HEATING SPEED UNTIL SITUATION CORRECTION

START TRIAL FOR IGNITION

THERMOSTAT CALLS FOR

HEAT, CONTACTS CLOSE

CONTROL BOARD ENERGIZED,

INDUCER ENERGIZED

PRESSURE SWITCH SENSES ADEQUATE DIFFERENTIAL PRESSURE CONTACTS CLOSE

POWER IS APPLIED TO

THE SILICON NITRIDE

IGNITOR. IGNITOR

WARM-UP IS 20 SECONDS

AFTER IGNITOR WARM-UP,

THE GAS VALVE IS

ENERGIZED TO OPEN

FLAME MUST BE

DETECTED WITHIN

4 SECONDS IF FLAME

IS DETECTED, THE

DELAY-TO-FAN-ON

TIME BEGINS (45 SECONDS)

POWER INTERRUPTION

SYSTEM SHUTS OFF,

RESTARTS WHEN

POWER IS RESTORED.

IF FLAME IS NOT

DETECTED, THE GAS VALVE

IS DE-ENERGIZED, THE

IGNITOR IS TURNED OFF AND THE CONTROL BOARD CONTROL GOES INTO "RETRY" SEQUENCE

27

Image 28
Contents GAS-FIRED Furnace Safety Section Page What to do if YOU Smell GAS All installations Table of Contents Section Beginning Page Closet Alcove III. Furnace Specifications Model GMD1-60 GMD1-80Blower Data GMD1-60Standard Chimney IV. Installation Roof JackFurnace Location Page Base Installation Page Alcove Installation Closet Installation  Warning Hazard Combustion AIR Page GAS Piping Electrical Wiring AWG Initial Start UP Adjustment of Heat Input RateOperating Instructions Supply Pressure Manifold Pressure NAT Burner Adjustment Setting Temperature Rise Furnace Checkout Procedure Installers Instructions to User VI. Starting the Unit Refer to the Troubleshooting Section of this Manual Page Diagnostic Features Power must be disconnected before servicingTurn Tstat Setting Above Room Temp Yes After GAS Valve OPENS, do the Burners IGNITE? Check ALL Electrical VIII. Dealer MaintenanceBurners Inducer Blower Assembly Inspecting the Venting SystemGASKETS/SEALING Materials Heat ExchangerHouse AIR Blower Extended ShutdownIX. User Information Section Component Locations Inspection AreasFilter Location and Cleaning Appendix a Replacement Parts Page Appendix B Wiring Diagram

GMD1-60N, GDM1-80N specifications

Thermo Products has established itself as a leader in the manufacturing of high-performance heating solutions. Among their notable offerings are the GDM1-80N and GMD1-60N units, which have garnered attention for their innovative features and reliable performance.

The GDM1-80N is designed for applications that require robust heating capabilities. This model boasts an impressive output capacity, making it suitable for industrial and commercial settings. One of its key features is the advanced temperature control system that ensures consistent heating across various environments. This system utilizes precision sensors that monitor temperature in real-time, allowing for adjustments to maintain the desired levels effectively.

Another notable characteristic of the GDM1-80N is its energy efficiency. It is engineered with state-of-the-art technology that minimizes energy consumption while maximizing heat output. This is particularly beneficial for businesses looking to reduce operational costs while still maintaining high-performance heating.

In contrast, the GMD1-60N is tailored for slightly less demanding applications but still delivers exceptional performance. With a compact design, it is ideal for spaces where floor space is limited without compromising on heating efficiency. The GMD1-60N features a user-friendly control interface, allowing operators to easily set and monitor temperatures.

Both models incorporate durable construction materials, ensuring longevity and reliability in various working conditions. The robust design means they can withstand the rigors of industrial use while providing consistent performance over time. Additionally, they are equipped with safety features, including overheat protection and user-accessible maintenance points, which enhance their usability and safety.

Thermo Products has integrated smart technology into these units, with options for remote monitoring and management through IoT devices. This capability allows users to track energy usage and system performance, facilitating better decision-making regarding heating needs and maintenance schedules.

In conclusion, the Thermo Products GDM1-80N and GMD1-60N units represent advanced heating solutions that cater to a range of industrial and commercial applications. With their emphasis on energy efficiency, durability, and smart technology, these models stand out as reliable choices for those seeking effective heating solutions in their operations.