All installations and services must be performed by qualified service personnel.

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK ALL

 

 

No

IS LED LIGHT

No

DOES SYSTEM RUN UNTIL

WIRING FOR

ON INTEGRATED

THERMOSTAT IS SATISFIED?

 

 

 

LOOSE

 

CONTROL FLASHING?

 

 

 

 

 

 

 

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK FOR SHORT IN

DOES BURNER SHUT OFF

No

WIRE TO THERMOSTAT

WHEN THERMOSTAT IS

 

AND CORRECT IF

SATISFIED?

 

 

NECESSARY.

 

 

 

 

 

 

IF LED FLASHES:

 

Yes

1 FLASH, THEN PAUSE SYSTEM LOCKOUT

 

 

2 FLASHES, THEN PAUSE

PRESSURE SWITCH STUCK CLOSED

 

3 FLASHES, THEN PAUSE

PRESSURE SWITCH STUCK OPEN

 

4 FLASHES, THEN PAUSE

OPEN LIMIT SWITCH OR ROLLOUT SWITCH

 

 

 

DOES THE CIRCULATING

6 FLASHES, THEN PAUSE

115 VOLT AC POWER REVERSED

AIR BLOWER TURN OFF

 

 

AFTER THERMOSTAT IS

7 FLASHES, THEN PAUSE

LOW FLAME SENSE SIGNAL

SATISFIED WITHIN

 

 

120 SECONDS?

8 FLASHES, THEN PAUSE

CHECK IGNITOR OR IMPROPER GROUNDING

 

CONTINUOUS FLASHING

FLAME HAS BEEN SENSED WHEN NO FLAME

 

(NO PAUSE)

SHOULD BE PRESENT (NO CALL FOR HEAT)

 

THE LED WILL ALSO FLASH ONCE AT POWER-UP.

Yes

CHECK COMPLETE SYSTEM OUT.

 

 

 

LED LIGHT STAYS ON CONTINUOUSLY,

 

COMPLETE FAILURE - REPLACE INTEGRATED CONTROL.

TROUBLESHOOTING COMPLETE.

 

 

34

Image 35
Contents GAS-FIRED Furnace Safety Section Page What to do if YOU Smell GAS All installations Table of Contents Section Beginning Page Closet Alcove GMD1-60 GMD1-80 III. Furnace Specifications ModelGMD1-60 Blower DataFurnace Location IV. Installation Roof JackStandard Chimney Page Base Installation Page Alcove Installation Closet Installation  Warning Hazard Combustion AIR Page GAS Piping Electrical Wiring AWG Operating Instructions Adjustment of Heat Input RateInitial Start UP Supply Pressure Manifold Pressure NAT Burner Adjustment Setting Temperature Rise Furnace Checkout Procedure Installers Instructions to User VI. Starting the Unit Refer to the Troubleshooting Section of this Manual Page Power must be disconnected before servicing Diagnostic FeaturesTurn Tstat Setting Above Room Temp Yes After GAS Valve OPENS, do the Burners IGNITE? Check ALL Burners VIII. Dealer MaintenanceElectrical Inspecting the Venting System Inducer Blower AssemblyExtended Shutdown GASKETS/SEALING MaterialsHeat Exchanger House AIR BlowerIX. User Information Section Inspection Areas Component LocationsFilter Location and Cleaning Appendix a Replacement Parts Page Appendix B Wiring Diagram

GMD1-60N, GDM1-80N specifications

Thermo Products has established itself as a leader in the manufacturing of high-performance heating solutions. Among their notable offerings are the GDM1-80N and GMD1-60N units, which have garnered attention for their innovative features and reliable performance.

The GDM1-80N is designed for applications that require robust heating capabilities. This model boasts an impressive output capacity, making it suitable for industrial and commercial settings. One of its key features is the advanced temperature control system that ensures consistent heating across various environments. This system utilizes precision sensors that monitor temperature in real-time, allowing for adjustments to maintain the desired levels effectively.

Another notable characteristic of the GDM1-80N is its energy efficiency. It is engineered with state-of-the-art technology that minimizes energy consumption while maximizing heat output. This is particularly beneficial for businesses looking to reduce operational costs while still maintaining high-performance heating.

In contrast, the GMD1-60N is tailored for slightly less demanding applications but still delivers exceptional performance. With a compact design, it is ideal for spaces where floor space is limited without compromising on heating efficiency. The GMD1-60N features a user-friendly control interface, allowing operators to easily set and monitor temperatures.

Both models incorporate durable construction materials, ensuring longevity and reliability in various working conditions. The robust design means they can withstand the rigors of industrial use while providing consistent performance over time. Additionally, they are equipped with safety features, including overheat protection and user-accessible maintenance points, which enhance their usability and safety.

Thermo Products has integrated smart technology into these units, with options for remote monitoring and management through IoT devices. This capability allows users to track energy usage and system performance, facilitating better decision-making regarding heating needs and maintenance schedules.

In conclusion, the Thermo Products GDM1-80N and GMD1-60N units represent advanced heating solutions that cater to a range of industrial and commercial applications. With their emphasis on energy efficiency, durability, and smart technology, these models stand out as reliable choices for those seeking effective heating solutions in their operations.