HP J3188A manual Led, Pattern

Page 14

Installing the Hub

Installing the Hub

Installing and Configuring Your Hub

2.Check the LEDs on the hub’s front panel. When the hub is powered on, it performs a power-on self test. See the table below for the LED pattern that occurs during the self test.

On for 20 seconds,

On for five

 

then enters

seconds, then

On for 20 seconds,

normal operating

enters normal

then enters

state.

operating

normal operating

 

state.

state.

LED

Pattern

 

 

Port LEDs,

ON for approximately 20 seconds, then enters normal operating

Fault, Security,

state.

AUI

 

 

 

Activity,

ON for approximately five seconds, then enters normal operating

Collision, RPS

state.

 

 

System

Stays ON.

 

 

Note that once you have connected cables to the hub, a Port LED stays on if link beat has been detected at the port. A Port LED turns off if link beat is not detected. The AUI port stays on if it is enabled.

When the self test completes successfully, the LEDs go into their normal operational states. If a hub hardware fault exists, the hub will not complete self test. This will be indicated by an abnormal LED pattern.

If the self test time elapses and the Fault LED continues to stay on instead of turning off, the hub may have an error condition. If repeating the self test does not correct the problem and the Fault LED still stays continu- ously on, contact your reseller for replacement information. After the hub has passed its self test, you are ready to mount the hub.

1-4

Image 14
Contents HP J3188A Page Installation and Reference Guide HP 10Base-T Hub-16M J3188APublication Number Back of the Hub HP 10Base-T Hub-16M J3188AFront of the Hub IiiFeatures Network ConnectionsContents Cables and Connectors Security Information ViiPage Installing the Hub Connect the external transceiver Installing and Configuring Your HubVerify included parts Verify the hub operates correctlyCord connected directly to the hub for proper operation TimeLED PatternMount the hub Rack or Cabinet MountingTable Mounting Connect the hub to your network Twisted-Pair Cascade Connections Connecting Devices to the HubConnecting Hubs Together Installing ThinLAN ConnectionsOhm terminator Connecting the Hub-16M to a Fiber-Optic Backbone Interpreting LED StatusInterpreting Hub Status LEDs Interpreting Port Status LEDs Following table provides LED port informationPage Troubleshooting Troubleshooting ApproachesProblem Solution Using a Checklist to Diagnose the HubTroubleshooting Using a Checklist to Diagnose the Hub LED Operation Power Coll Troubleshooting LED OperationDiagnostic Tips Hub will automatically recover afterClearing a Password for the Ascii Console Hub Maintenance TasksTesting the Hub Only Obtaining Firmware Enhancements Troubleshooting Hub Maintenance TasksRunning Connectivity Tests Setting up the Ascii Console Managing the HubManaging the Hub Directly, Using a Serial Cable and a TerminalRemotely, Using Telnet Remotely, Using a Modem and a Terminal Starting the ConsoleExample HE ST This displays help for the Status command Console Command ReferenceCommands are described in the rest of the chapter Syntax Conventions on Help ScreenBAckup Default DescriptionCounter Name Definition Valid Range CDpstatusCOunters RangeDIsconnect IPconfigWhen to Use IPconfig Using IP Configuring for Network ManagementUsing Novell NetWare IPX Following table explains the IP parametersParameter Default Value Definition MAnagers SHowTo end your editing CommandManager Address IP or IPX Receive Alarms? NEighbor Displays the other devices that are using CDP protocolMEssageinterval Table entry with ID 1 would now be a blank linePIng PAsswordClear a password Community nameRObustness REsetPOrt port ON/OFF Security Configuration Parameter Definitions SEcure portSHowCLearManaging the Hub Eavesdrop Prevention, must be set to on Configuring Security on a Single PortConfiguring Security on All Twisted-Pair Ports Address Selection Authorized Showing the Security Configuration Clearing Security Violation IndicatorsSPeed new speed STatusStatus Information What It Means 16M will respond with the correct packet Network links, see the , TroubleshootingTEstlink To sendPage Following table shows PC connections to the RS-232 port Cables and ConnectorsRecommended Cables Cable Function Cable Type HP Product Number Cables and ConnectorsFollowing table shows network connections to the hub Pins 3 and 6 must be a twisted pair Twisted-Pair Cable/Connector Pin-OutsPins 1 and 2 must be a twisted pair Twisted-Pair Cable for Hub-to-Computer Network ConnectionCable pin-out described below RS-232 Connector and Cable Pin-OutsInstaller for assistance with your cabling requirements Minimum pin-out will function correctlyRS-232 Modem Cable SignalMinimum Cable Pinout for Ascii Console Connection Hub End MDI-X Twisted-Pair Cable Pin AssignmentsTwisted-Pair Straight-Through Cable Electrical SpecificationsPhysical EnvironmentalElectromagnetic ConnectorsSpecifications Megahertz XJ2288 Pcmcia card modem Modem ConfigurationUS Robotics Courier V.FC/V.34 Supra FAX Practical Peripherals PM288MT IIIntel 14.4EX Network Addressing Communication Between the Hub Network Management StationIPX Addressing Notes IPX Addressing for Novell NetWareIP Addresses for IP and Non-IP Networks Globally Assigned IP Network AddressesCompany Name/Address Device IP ConfigurationCountry Using Bootp Bootp ProcessBootp Table File Entries Definitions of the table entry fieldsPage Backup Links How Backup Links WorkAdditional Notes Backup LinksLimitations Hub to a Switch Examples of Backup LinksHow the Backup Function Works Hub to a ServerT e G g e s t i o n Hub can monitor only one linkConfiguring a Backup Link Configuration/Installation SequenceIdentifying the Backup Link Indications of Backup Link ActivationReactivating the Primary Link Page Security Information Understanding Network SecurityAuthorized MAC address How Intruder Prevention WorksHow Eavesdrop Prevention Works Security InformationAssigning the Authorized MAC address Setting Inbound Security with Intruder Prevention Auto Port Disable Send AlarmSetting Outbound Security with Eavesdrop Prevention Security Information Page Safety and Regulatory Statements Mounting PrecautionsSettings to configure Power PrecautionsTemperature might exceed 45C 113F Equipment and should be easily accessibleSafety Information GroundingInformations concernant la sécurité Tible de causer des dommages à léquipementHinweise zur Sicherheit Considerazioni sulla sicurezza Consideraciones sobre seguridad Safety Information Japanese European Community Regulatory StatementsFCC Class a Statement for U.S.A. Only CanadaDeclaration of Conformity Index IndexDiagnosing with the LEDs … 2-2 diagnostic tests Late collision … 3-13 mounting the hub … LED description … Verifying hub operation … Page J3188-90001