STT 110 / STT 160
5.1. Maintenance schedule
Daily: | Check warning signs on equipment for good |
| legibility and completeness |
| Clean return air filters and casing (depending |
| on dust |
Weekly: | Check main switch for proper function |
| Check the signal lamps for proper functioning |
Every six months: | Change return air filters (depending on dust |
| Clean air filter of the suction box |
| All electrical and mechanical connections |
| should be checked to see if they fit securely |
Annually: | Dewpoint should be checked (only by |
| Sterling service personnel) |
Whenever the |
|
material is changed: | The drying hopper and suction box must be cleaned |
&
F
The service intervals refer to a
The given maintenance intervals are average values.
Check whether in your individual case the maintenance intervals must be shortened.