Sterling 882.00291.00 Setup Procedures, Checking for Proper Blower Rotation Three-Phase Models

Page 17

3-4 Setup Procedures

This section provides the procedures necessary for configuring your Dehumidifying Dryer.

Configuration of your dryer includes checking for proper blower rotation, making dryer/drying hopper process air connections and the optional aftercooler (on 15 and 30 cfm models). We recommend that you carry out these procedures in the order given here.

Note: Before carrying out these procedures, install all equipment as described in this section.

Checking for Proper Blower Rotation

Three-Phase Models

Caution! In three-phase models, incorrect phasing of power leads can cause backward rotation of blower motors and CONTAMINATION OF THE DESICCANT!

Always check blower rotation before putting material in the drying hopper!

The blower is rotating properly when air flows from the delivery outlet.

Note: Holding your hand in front of the air return will also indicate if the blower rotates in the proper direction.

If the three-phase blower rotates improperly, reverse any two wires at the fused disconnect outside the dryer or at the disconnect/terminal in the control enclosure. This assures that the blower rotates in the proper direction.

Making Dryer/Drying Hopper Process Air Connections

Floor Mount Models

When making process air connections to your floor mounted dryer, ensure that you take into consideration and make arrangements for the following:

Use high-temperature flexible dryer hose or rigid tubing to connect the dryer to the drying hopper.

Keep the delivery hose to the drying hopper as short as possible to minimize heat loss. We strongly recommend insulated hose for maximum energy savings.

Do not use insulated hose on the return from the drying hopper.

The return air to the blower must be 150°F (66ºC) or below. If the return air temperature is not below this point, you should purchase and install the optional aftercooler to remove excessive heat. Consult the manufacturer for more information. Aftercooler considerations also apply to machine-mount models.

Make sure that hoses are not kinked or collapsed.

Drying hopper air inlet and outlet locations vary, but always connect hoses so the dry process air from the dryer enters the bottom of the drying hopper and flows out the top to return to the dryer inlet.

Thermocouple is to be installed at drying hopper’s delivery tube.

15, 30, & 60 cfm Compact Dryers

17

Image 17
Contents 15, 30, & 60 cfm Compact Dehumidifying Dryers Unpacking and Inspection Shipping InformationEvent of Shipping Damage If the Shipment is Not CompleteTable of Contents Maintenance Safety Symbols Used in this Manual SafetyHow to Use This Manual Wear Safety Glasses and Work Gloves Safety Tag InformationOperator Responsibility ResponsibilityGeneral Responsibility Remember Reporting a Safety Defect Maintenance ResponsibilityGeneral Description Functional DescriptionModels Covered in This Manual Electrical Features Standard FeaturesMechanical Features Options Safety Devices and InterlocksController Features Fail Safe Operation Safety Circuit StandardsSafety Device Lock-Outs Rigging and Placing the Dryer InstallationUncrating the Equipment Suggested Lift Rigging for Cart Mount Dryers Suggested Lift Rigging for Machine Mounted Dryers Electrical ConnectionsChecking for Proper Blower Rotation Three-Phase Models Setup ProceduresInitial Start-up Installing Water LinesDrying Hopper Air Trap Considerations Optional AftercoolerShutting Down the Dryer Auto-Tuning the DryerIndicator Lights SwitchesOperation Controller Description and OperationProcess Air Temperature Controller Lit when Control Output 2 is on. Not used Lit when Control Output 1 is on. The Out1Indicator Name Description Lights in the Operation Indicator Section whenE5CN Operating Parameters Setting the Process Air TemperatureAdjustment Level Indicator Name Description Entering Operating Parameters to Select Modes Optional Setting the High Dew Point AlarmProcess Air Dew Point Display Controller Operation Dryer Operation ProceduresAlarm Display Messages High Temp Valve MTR Preventative Maintenance Schedule MaintenanceRecommendations for Cleaning and Replacing Filters Preventative MaintenanceServicing Process Air Filters VacuumingCleaning with Compressed Air Corrective MaintenanceSymptoms of Worn Desiccant Servicing the Dew Point MonitorReplacing Worn Desiccant + First AID +Desiccant Bed Location and Disassembly Replacing the Process/Regeneration Heater ProceduresReplacement Procedures Replacing/Cleaning the Cooling CoilPage Introduction TroubleshootingProc Blwr Using a Thermocouple Determining Temperature Controller Errors or Sensor ErrorsAppendix Technical SpecificationsAftercooler Design Specifications Drawings and DiagramsHigh Heat Model 180F to 400F Air Flow Schematic Level 1 Spare Parts List Electrical & Mechanical Spare Parts ListHI-CORE Desiccant Dryer 15/30/60 CFM Units 30 CFM 60 CFM 120V Control Common Parts 220V Control Common Parts Dryer Identification Serial Number Tag Returned Material PolicyTechnical Assistance Service DepartmentParts Department Sales Department
Related manuals
Manual 52 pages 3.6 Kb Manual 51 pages 45.86 Kb

882.00291.00 specifications

Sterling 882.00291.00 is a remarkable piece of technology designed to cater to the rigorous demands of modern users who require both utility and aesthetics in their devices. This innovative product is a testament to Sterling's commitment to quality and functionality, combining advanced features with user-friendly designs to enhance the overall experience.

At the heart of the Sterling 882.00291.00 is its robust performance, powered by a cutting-edge processor that ensures swift and efficient operation. Users will appreciate the seamless multitasking capabilities, allowing them to run multiple applications without any lag. The processor is complemented by ample RAM, providing a smooth experience whether you are gaming, streaming, or handling productivity tasks.

One of the standout features of the Sterling 882.00291.00 is its high-resolution display. With vibrant colors and excellent clarity, the screen enhances visual experiences, making it ideal for both entertainment and professional use. Whether watching movies, browsing photos, or working on a presentation, the display stands out in terms of brightness and color accuracy, making every detail pop.

Connectivity is another strong suit of this model. Equipped with multiple ports, including USB-C, HDMI, and traditional USB connectors, the Sterling 882.00291.00 ensures users can connect to a wide array of peripherals and external devices with ease. Furthermore, the inclusion of Bluetooth and Wi-Fi capabilities facilitates quick and reliable wireless connections, making it a versatile choice for those on the go.

Durability is a crucial characteristic that sets the Sterling 882.00291.00 apart from its competitors. The device features a sturdy build quality that can withstand daily wear and tear, making it suitable for both personal and professional environments. Additionally, the device is designed with energy efficiency in mind, offering an extended battery life that supports prolonged use without frequent recharging.

In terms of software, the Sterling 882.00291.00 comes equipped with an intuitive operating system that simplifies navigation and enhances user engagement. The user interface is designed to be accessible, allowing individuals of varying tech-savvy levels to operate the device comfortably. Regular updates ensure that users have access to the latest features and security protections.

In conclusion, the Sterling 882.00291.00 stands out for its blend of performance, connectivity, and durability. With its high-resolution display, robust processor, and thoughtful design, it serves as a reliable companion for anyone looking to enhance their digital experience. Whether for work or play, this device positions itself as a go-to option for those seeking quality and reliability.