Thermo Products PHCFA072DV4R Electrical Wiring, Electrical Connections, Room Thermostat

Page 20

the pump. Pitching the line upward toward the tank will help prevent the formation of air pockets in the line.

J. ELECTRICAL WIRING:

: This appliance must be grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70-1999, or the latest edition.

Electrical Connections

NOTICE: All field wiring must conform to local, state, and national installation codes.

A disconnection switch equipped with overcurrent protection rated at 15 A. (e.g. a time delay- type fuse or inverse time, circuit breaker) should be installed in the service line for shutting down and protecting the furnace and electrical system.

Since the furnace is entirely pre-wired at the factory, it is only necessary to connect the building electrical service lines to the two (2) pigtail wires extending from the 2x4 junction box. The fan timer board is mounted inside the furnace blower compartment. The service lines to the furnace should be no smaller than 14 Ga., insulated copper wire with a temperature rating of 600C, or greater.

Connect an equipment ground wire to the furnace at the 2x4 junction box. If wiring

is run through metal electrical conduit, it may not be necessary to run a separate equipment ground wire. Consult local codes and authorities for specific minimum requirements.

A two (2) wire connection to the room thermostat from the fan timer board is also

necessary. This is typically a low voltage (24 VAC) circuit. Consult the National Electrical Code, ANSI/NFPA 70-2002 or latest edition, for guidelines for proper wiring methods and materials for this circuit.

Refer to the electrical diagrams contained in Appendix B of this manual for an electrical schematic, a connection diagram, and operating instructions.

Room Thermostat

A room thermostat is not furnished with this furnace. However, a thermostat is required to properly operate the furnace control system in a typical residential heating application.

The room thermostat should be located on an interior wall in the natural circulating path of the room air.

The thermostat should not be installed in a location where it is directly exposed to,

cold air infiltration, i.e. drafts from outside openings such as windows and doors,

air currents produced by supply air registers, and

heat from a nearby source, such as a fireplace, electrical appliances, lamps, solar radiation, a wall enclosing warm air ducts, a chimney, or a flue gas vent.

17

Image 20
Contents OIL Fired Furnace OHCFA072DV4RContents = Highboy D = Downflow = FrontCAUTION do not Attempt to Start the Burner When Safety SectionWARNING and Cautions Page Codes and Clearances Combustible material Non-combustible materialHighboy OHCFA072DV4RII. General Instructions Venting Fig-1 Installation of Ventor Fig-2Fig-3 Page Condensate Drain Line Connections Fig-4Duct WORK/AIR Conditioning Air Filter Mounted External to Furnace Ft/min Maximum Model Number Filter Type Air VelocityOHC Burner Installation Burner Specifications and ApplicationsLimit Position and Location Fig-7OIL Tank and Piping RielloBTU/HR OHCFA072DV4R 75,000 72,000Page Room Thermostat Electrical WiringElectrical Connections Post-Purge Timer Electronic Air Cleaner EAC and Humidifier InstallationThermostat Anticipator Setting Blower Motor Speed SelectionOHCFA072DV4 Alterations REQ’D for A/C @ Design External Static PressureInputs Terminal Definitions & Field WiringBlower Controller Information for ECM Motor Outputs Operating Modes On and OFF Blower Delay Time Switch Settings Diagnostic Features Trouble ShootingStartup Procedures To Turn Off Oil to Appliance Sequence of Operation for the OHCPage Page Adjustment Of Heat Input Rate Setting Supply Air Temperature RiseCheckout Procedure Filter Cleaning and Location III. Users Information SectionInspection Areas  Caution do not Attempt to Make Repairs YourselfIV. Installers Instructions to User Dealer Maintenance Safety During Servicing and Inspection General InspectionHeat Exchanger Cleaning Instructions Page Fig-12 Fig-13 Filter maintenance procedure Electrical SystemSUPPLY/RETURN AIR Blower SUPPLY/RETURN AIR FilterOn Shutdown Filter replacementExtended Appliance Shutdown On Startup VI. HOMEOWNER/USER Information and Routine Maintenance Fig-16 Page Page Page Page Page Page Customer Appendix a Replacement Parts OHC BF3 Riello Burner Page Appendix B Wiring Diagram

PHCFA072DV4R specifications

The Thermo Products PHCFA072DV4R is a cutting-edge heating and cooling solution designed for modern residential and light commercial applications. This unit stands out due to its efficient performance and advanced technology. One of the most remarkable features of the PHCFA072DV4R is its energy efficiency. It boasts a high SEER rating that ensures reduced energy consumption without sacrificing comfort, making it an environmentally friendly choice for homeowners.

This system utilizes an inverter-driven compressor, which allows for variable speed operation. This means that the unit can adjust its output to match the specific heating or cooling needs of a space, providing more consistent temperatures and enhanced comfort. Additionally, this inverter technology minimizes noise levels, making the PHCFA072DV4R a quieter option compared to traditional fixed-speed systems.

Another noteworthy characteristic of the PHCFA072DV4R is its advanced filtration system. It is equipped with high-efficiency filters that effectively capture dust, pollen, and other airborne particles, ensuring improved indoor air quality. For those who suffer from allergies or have respiratory issues, this feature can provide significant relief.

The unit offers a user-friendly interface with a smart thermostat that enables users to control the system remotely. Through a mobile app, homeowners can adjust settings, set schedules, and monitor energy usage from anywhere, which adds a layer of convenience to the overall user experience.

Additionally, the PHCFA072DV4R is built with durability in mind. Its robust construction and high-quality materials ensure long-term reliability, reducing the likelihood of costly repairs. It also comes with a warranty that reflects the manufacturer's confidence in the product's performance.

Overall, the Thermo Products PHCFA072DV4R encapsulates efficiency, comfort, and advanced technology in a single package. Its ability to adapt to varying conditions, combined with features focused on air quality and ease of use, make it a prime choice for anyone looking for a versatile heating and cooling solution. This unit not only meets the demands of today's consumers but also aligns with sustainable practices, making it an ideal addition to any home or business.