Thermo Products PHCFA072DV4R operation manual Checkout Procedure

Page 33

Temperature rise = supply air temperature - return air temperature.

After 15 to 20 minutes of continuous operation, the temperature rise through the furnace must fall within a range of 55° to 85° F. If the outlet or supply duct temperature is too high, check to make sure the return air filter is clean, the return air registers are free from obstruction, the outlet registers are properly adjusted and clear, and the supply and return air ducts are open. The circulating air blower is not moving enough air if the supply air temperature is still too high. Before proceeding further, turn off the power supply to the appliance and remove the vestibule cover. The speed of the blower must be increased by changing the switch setting on the control board, please refer to Table 6.

5. Checkout Procedure:

Before any system of oil piping is finally put into service, it shall be carefully tested to assure that it is “gas-tight”, as indicated in the Heating System Initial Startup section of this manual.

NOTICE: All controls on the unit should be checked for proper functioning prior to the qualified service personnel leaving the job site. Specifically the following should be checked:

a.With heating system in normal heating operation, check to make certain blower will start and stop automatically under control of the indoor thermostat.

b.Check safety limit control as follows:

i.Shut off incoming power.

ii.Block return air opening or disconnect blower motor leads.

iii.Restore power to appliance.

iv.In the heating mode, set the thermostat above room temperature producing “a call for heat”.

v.When high air temperatures are reached within the heating section, the high limit control should act to shutdown the burner.

vi.Shut off the electrical power.

IMPORTANT: Remove blockage or reconnect blower motor and restore power.

c. Make certain the thermostat will automatically start and stop the appliance.

NOTICE: Heat exchanger oil will burn off on initial firing creating an unpleasant odor. To prevent this odor from occurring more than once, it is suggested the heating section be allowed to run for 30 minutes, or until odor has dissipated.

30

Image 33
Contents OHCFA072DV4R OIL Fired FurnaceContents = Front = Highboy D = DownflowSafety Section WARNING and CautionsCAUTION do not Attempt to Start the Burner When Page Codes and Clearances Non-combustible material Combustible materialHighboy OHCFA072DV4RII. General Instructions Venting Fig-1 Fig-2 Installation of VentorFig-3 Page Fig-4 Condensate Drain Line ConnectionsDuct WORK/AIR Conditioning Air Filter Mounted External to Furnace Maximum Model Number Filter Type Air Velocity OHCFt/min Burner Specifications and Applications Burner InstallationLimit Position and Location Fig-7Riello OIL Tank and PipingBTU/HR OHCFA072DV4R 75,000 72,000Page Electrical Wiring Electrical ConnectionsRoom Thermostat Electronic Air Cleaner EAC and Humidifier Installation Post-Purge TimerBlower Motor Speed Selection Thermostat Anticipator SettingAlterations REQ’D for A/C @ Design External Static Pressure OHCFA072DV4Terminal Definitions & Field Wiring Blower Controller Information for ECM MotorInputs Outputs Operating Modes On and OFF Blower Delay Time Switch Settings Trouble Shooting Startup ProceduresDiagnostic Features Sequence of Operation for the OHC To Turn Off Oil to AppliancePage Page Setting Supply Air Temperature Rise Adjustment Of Heat Input RateCheckout Procedure III. Users Information Section Filter Cleaning and LocationInspection Areas  Caution do not Attempt to Make Repairs YourselfIV. Installers Instructions to User General Inspection Dealer Maintenance Safety During Servicing and InspectionHeat Exchanger Cleaning Instructions Page Fig-12 Fig-13 Electrical System Filter maintenance procedureSUPPLY/RETURN AIR Blower SUPPLY/RETURN AIR FilterFilter replacement Extended Appliance ShutdownOn Shutdown On Startup VI. HOMEOWNER/USER Information and Routine Maintenance Fig-16 Page Page Page Page Page Page Customer Appendix a Replacement Parts OHC BF3 Riello Burner Page Appendix B Wiring Diagram

PHCFA072DV4R specifications

The Thermo Products PHCFA072DV4R is a cutting-edge heating and cooling solution designed for modern residential and light commercial applications. This unit stands out due to its efficient performance and advanced technology. One of the most remarkable features of the PHCFA072DV4R is its energy efficiency. It boasts a high SEER rating that ensures reduced energy consumption without sacrificing comfort, making it an environmentally friendly choice for homeowners.

This system utilizes an inverter-driven compressor, which allows for variable speed operation. This means that the unit can adjust its output to match the specific heating or cooling needs of a space, providing more consistent temperatures and enhanced comfort. Additionally, this inverter technology minimizes noise levels, making the PHCFA072DV4R a quieter option compared to traditional fixed-speed systems.

Another noteworthy characteristic of the PHCFA072DV4R is its advanced filtration system. It is equipped with high-efficiency filters that effectively capture dust, pollen, and other airborne particles, ensuring improved indoor air quality. For those who suffer from allergies or have respiratory issues, this feature can provide significant relief.

The unit offers a user-friendly interface with a smart thermostat that enables users to control the system remotely. Through a mobile app, homeowners can adjust settings, set schedules, and monitor energy usage from anywhere, which adds a layer of convenience to the overall user experience.

Additionally, the PHCFA072DV4R is built with durability in mind. Its robust construction and high-quality materials ensure long-term reliability, reducing the likelihood of costly repairs. It also comes with a warranty that reflects the manufacturer's confidence in the product's performance.

Overall, the Thermo Products PHCFA072DV4R encapsulates efficiency, comfort, and advanced technology in a single package. Its ability to adapt to varying conditions, combined with features focused on air quality and ease of use, make it a prime choice for anyone looking for a versatile heating and cooling solution. This unit not only meets the demands of today's consumers but also aligns with sustainable practices, making it an ideal addition to any home or business.