Thermo Products PHCFA072DV4R operation manual Post-Purge Timer

Page 21

 

 

 

 

 

Maximum

 

 

 

 

 

Oil Burner

Time Delay

Minimum

 

 

 

Supply/Return

Type Fuse

 

Voltage/Frequency

OHC Full Load

Air Blower Full

Assembly

or Inverse

Recommende

Model

No. of Phases

Current (Amps) @

Load Current

Full Load

Time

d 75 deg. C.

Current

Copper

 

(V/Hz/Ph)

120 VAC

(Amps) @ 120

Circuit

 

(Amps) @

Power Wiring

 

 

 

VAC

Breaker

 

 

 

120 VAC

Size (AWG)

 

 

 

 

Size

 

 

 

 

 

 

 

 

 

 

 

(Amps)

 

 

 

 

 

 

 

 

OHCFA072DV4

120/60/1

11.45

7.15 ECM

2.5

15

12

Table 5: Typical Electrical Requirements

Post-Purge Timer:

This furnace is equipped with a post-purge timer located in the blower compartment on the control panel. It is pre-set at the factory for a 4 minute post-purge. This is designed to ensure that no residual heat or combustion odors permeate back into the home. The 4 minutes has been deemed sufficient, however if you experience the need for a longer post-purge, the device has 3 selectable settings; 4 minutes, 5 minutes and 7 minutes. By simply turning the knob to one of the remaining selections the post-purge time will be effected.

Fig-7A Post Purge Timer

Electronic Air Cleaner (EAC) and Humidifier Installation:

The fan timer on this unit has designated terminals to control the operation of an electronic air cleaner and/or humidifier. These terminals provide line voltage for the control of these accessories, refer to Figure 8 on the next page. Connection between EAC and N6 provides a switched 115 vac to power an electronic fan cleaner. The same-switched 115 vac is available between Fan and N7 and may be used in conjunction with a humidistat to control a humidifier. These terminals are energized whenever the blower is active.

18

Image 21
Contents OHCFA072DV4R OIL Fired FurnaceContents = Front = Highboy D = DownflowSafety Section WARNING and CautionsCAUTION do not Attempt to Start the Burner When Page Codes and Clearances Non-combustible material Combustible materialHighboy OHCFA072DV4RII. General Instructions Venting Fig-1 Fig-2 Installation of VentorFig-3 Page Fig-4 Condensate Drain Line ConnectionsDuct WORK/AIR Conditioning Air Filter Mounted External to Furnace Maximum Model Number Filter Type Air Velocity OHCFt/min Burner Specifications and Applications Burner InstallationLimit Position and Location Fig-7Riello OIL Tank and PipingBTU/HR OHCFA072DV4R 75,000 72,000Page Electrical Wiring Electrical ConnectionsRoom Thermostat Electronic Air Cleaner EAC and Humidifier Installation Post-Purge TimerBlower Motor Speed Selection Thermostat Anticipator SettingAlterations REQ’D for A/C @ Design External Static Pressure OHCFA072DV4Terminal Definitions & Field Wiring Blower Controller Information for ECM MotorInputs Outputs Operating Modes On and OFF Blower Delay Time Switch Settings Trouble Shooting Startup ProceduresDiagnostic Features Sequence of Operation for the OHC To Turn Off Oil to AppliancePage Page Setting Supply Air Temperature Rise Adjustment Of Heat Input RateCheckout Procedure III. Users Information Section Filter Cleaning and LocationInspection Areas  Caution do not Attempt to Make Repairs YourselfIV. Installers Instructions to User General Inspection Dealer Maintenance Safety During Servicing and InspectionHeat Exchanger Cleaning Instructions Page Fig-12 Fig-13 Electrical System Filter maintenance procedureSUPPLY/RETURN AIR Blower SUPPLY/RETURN AIR FilterFilter replacement Extended Appliance ShutdownOn Shutdown On Startup VI. HOMEOWNER/USER Information and Routine Maintenance Fig-16 Page Page Page Page Page Page Customer Appendix a Replacement Parts OHC BF3 Riello Burner Page Appendix B Wiring Diagram

PHCFA072DV4R specifications

The Thermo Products PHCFA072DV4R is a cutting-edge heating and cooling solution designed for modern residential and light commercial applications. This unit stands out due to its efficient performance and advanced technology. One of the most remarkable features of the PHCFA072DV4R is its energy efficiency. It boasts a high SEER rating that ensures reduced energy consumption without sacrificing comfort, making it an environmentally friendly choice for homeowners.

This system utilizes an inverter-driven compressor, which allows for variable speed operation. This means that the unit can adjust its output to match the specific heating or cooling needs of a space, providing more consistent temperatures and enhanced comfort. Additionally, this inverter technology minimizes noise levels, making the PHCFA072DV4R a quieter option compared to traditional fixed-speed systems.

Another noteworthy characteristic of the PHCFA072DV4R is its advanced filtration system. It is equipped with high-efficiency filters that effectively capture dust, pollen, and other airborne particles, ensuring improved indoor air quality. For those who suffer from allergies or have respiratory issues, this feature can provide significant relief.

The unit offers a user-friendly interface with a smart thermostat that enables users to control the system remotely. Through a mobile app, homeowners can adjust settings, set schedules, and monitor energy usage from anywhere, which adds a layer of convenience to the overall user experience.

Additionally, the PHCFA072DV4R is built with durability in mind. Its robust construction and high-quality materials ensure long-term reliability, reducing the likelihood of costly repairs. It also comes with a warranty that reflects the manufacturer's confidence in the product's performance.

Overall, the Thermo Products PHCFA072DV4R encapsulates efficiency, comfort, and advanced technology in a single package. Its ability to adapt to varying conditions, combined with features focused on air quality and ease of use, make it a prime choice for anyone looking for a versatile heating and cooling solution. This unit not only meets the demands of today's consumers but also aligns with sustainable practices, making it an ideal addition to any home or business.