Thermo Products OH5-85DXE Nozzle Size Input Rate Effective, Heating, BTU/HR Capacity High Fire

Page 10

All installations and services must be performed by qualified service personnel.

G. BURNER SPECIFICATIONS AND APPLICATIONS

RIELLO BURNER APPLICATION CHART

MODEL

OH5 2 STAGE

PART

 

MTG. PLATE

35750

PART NO.

 

MTG. PLATE

 

GASKET

330088

PART NO.

 

**NOZZLE

.70 X 45° W

SIZE

 

NOZZLE

380702

PART NO.

 

OIL PUMP

130 LOW

170

PRESSURE

HIGH

 

BURNER

G-51

BURNER

380695

PART NO.

 

* INSULATOR S = SLEEVE OR N = NONE

THE NOZZLE SIZE GIVES THE NOMINAL FLOWRATE, IN GPH, FOLLOWED BY THE SPRAY ANGLE, IN DEGREE’S, AND THE SPRAY PATTERN, EITHER “H” FOR HOLLOW CONE OR “S” FOR SOLID CONE. FOR EXAMPLE, A NOZZLE RATED AT 0.65 GPH @ 100 PSIG THAT PROVIDES AN 80° SPRAY ANGLE AND A HOLLOW SPRAY PATTERN WOULD BE ABBREVIATED IN THE TABLE AS “0.65 X 80°H”.

**NOTE: The reason the Riello burner nozzle sizes are smaller than the standard Thermo Pride burner nozzles is that pre-set pump pressures are higher, therefore achieving the same firing rate with a smaller nozzle.

For more specific burner information, specifications or service information, reference the training manual enclosed

with each Riello burner or contact: Riello Corporation of America, 5 Pond Park Road

Hingham, Massachusetts 02043 (617) 749-8292

2 STAGE FIRING RATES

 

NOZZLE SIZE

INPUT RATE*

EFFECTIVE**

OH5-85DXE***

HEATING

Riello

(BTU/HR)

CAPACITY

HIGH FIRE

 

106,250/170psi

85,000

LOW FIRE

.70 X 45° W

85,000/130psi

74,000

*Based on #2 domestic heating fuel oil having heating value of 140,000 BTU per gallon.

**Based on thermal efficiency of 84%-85%.

7

Image 10
Contents OIL Fired Furnace OH5-85DXESafety Section Table of Contents Section Beginning NON-COMBUSTIBLE Material II. General Instructions Read Before Start of InstallationCombustible Material From Rear FLUE/VENTUnit DIA. Hole Venting Rotation of Front Flue ElbowTrim Collar Flue DIA Gasket OH5-85DXEDuct WORK/AIR Conditioning Filters Mounted External to FurnaceCutaway view of fan section of a typical highboy furnace Limit Position and Location Burner InstallationRiello Mounting Plate Top view Burner insertion illustration BTU/HR Capacity High Fire Nozzle Size Input Rate EffectiveHeating LOW FireHeat Exchanger Cleaning Instructions Inspection Areas III. Users Information SectionStarting the Burner Filter Cleaning and Location Location of the air filter on the typical highboy furnaceCustomer APPENDIX-A Replacement Parts List APPENDIX-B Wiring Diagram