Thermo Products OH5-85DXE operation manual Filter Cleaning and Location

Page 13

All installations and services must be performed by qualified service personnel.

4.Turn service switch to furnace "ON". If burner starts and runs, but stops again on lockout, it may be necessary to bleed the lines or make burner combustion air adjustments. Contact a qualified service person to adjust and start burner.

E. FILTER CLEANING AND LOCATION:

The air filters should be inspected each month and cleaned when dirty. Cleaning the air filters frequently may reduce airborne contaminants from entering the furnace and depositing in the furnace, duct system and home.

cWARNING: To avoid injury from moving parts, hot surfaces, or electrical shock, shut off the power to the furnace before removing any furnace access doors to service the air filters.

The filter rack will be located between the return air plenum and the return air opening on the side of the furnace, refer to figure 18. Slide the dirty filter out, clean it with a mild soap and water solution. Make sure filter is thoroughly dry before replacing.

Fig. 18: Location of the air filter on the typical highboy furnace.

10

Image 13
Contents OH5-85DXE OIL Fired FurnaceSafety Section Table of Contents Section Beginning Combustible Material II. General Instructions Read Before Start of InstallationNON-COMBUSTIBLE Material From Rear FLUE/VENTTrim Collar Venting Rotation of Front Flue ElbowUnit DIA. Hole Flue DIA Gasket OH5-85DXEFilters Mounted External to Furnace Duct WORK/AIR ConditioningCutaway view of fan section of a typical highboy furnace Limit Position and Location Burner InstallationRiello Mounting Plate Top view Burner insertion illustration Heating Nozzle Size Input Rate EffectiveBTU/HR Capacity High Fire LOW FireHeat Exchanger Cleaning Instructions Inspection Areas III. Users Information SectionStarting the Burner Location of the air filter on the typical highboy furnace Filter Cleaning and LocationCustomer APPENDIX-A Replacement Parts List APPENDIX-B Wiring Diagram